5925-00-121-9847

Circuit Breaker

5925001219847 001219847 SAE-AS58091 Q531487051 7274-4-1/2 CP53B1EF105K1 10503365 MS26574-1/2A 84402811 972.55.18.510 84 303 308 SP 4307-11 AS58091 MIL-C-5809 AS26574

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER. View more Circuit Breaker

5925-00-121-9847 CIRCUIT BREAKER 5925001219847 001219847

Managed by United States
NSN Created on 4 Nov 1968
Data Last Changed
November 2023
NATO Update Count
47
NATO Data Quality
AAQL Style 1A for 5925-00-121-9847 1/1
NSN 5925-00-121-9847 (Identification) 1/1

5925-00-121-9847 Stock and Availability Marketplace 5925-00-121-9847

Need Help?
Request a Quotation from participating marketplace vendors
eBay Updated Every Day
5925-00-121-9847 RQST NE eBay
eBay Updated Every Day
5925-00-121-9847 RQST eBay
Amazon Updated Every Day
5925-00-121-9847 RQST NE Amazon

5925-00-121-9847 Related Documents Related Documents 5925-00-121-9847 5+ Documents (More...)

for $1 a day Upgrade your Account Upgrade 5925-01-432-5167Circuit Breaker5925014325167 014325167 SAE-AS58091
MS25361-100V AS58091 MIL-C-5809 A device with means other than fuses for automatically opening the circuit
/fsg-59/fsc-5925/us 5925-01-390-0641 Circuit Breaker 5925013900641 013900641 AS58091 MIL-C-5809 MS14154
AS26574 MS26574-20 AS58091 MIL-C-5809 A device with means other than fuses for automatically opening
MS26574-15 AS58091/1 MIL-C-5809AS58091 MS26674-15 AS26574 A device with means other than fuses for AS58091
AS58091 AS24510 5925PL0891205 A device with means other than fuses MIL-C-5809 CIRCUIT BREAKER 6 EA NS
for $1 a day Upgrade your Account Upgrade 5925-01-390-0641Circuit Breaker5925013900641 013900641 SAE-AS58091
AS58091 MIL-C-5809 MS14154-20V A device with means other than fuses for automatically opening the circuit
/1 MIL-C-5809AS58091 MS26674-15 AS26574 A device with means other than fuses for MIL-C-5809 CIRCUIT
/1 MIL-C-5809 AS58091 MS26674-15 AS26574 A device with means other than fuses for MIL-C-5809 CIRCUIT
AS58091 AS24510 5925PL0891205 A device with means other than fuses MIL-C-5809 CIRCUIT BREAKER 6 EA NS
MS26574-20 AS58091 MIL-C-5809 A device with means other than fuses for automatically opening MIL-C-5809
MS22073-15V AS58091 MIL-C-5809 AS22073 A device with means other than fuses for automatically opening
AS58091 AS24510 5925PL0891205 A device with means other than fuses MIL-C-5809 CIRCUIT BREAKER 6 EA NS
AS58091 AS24510 5925PL0891205 A device with means other than fuses MIL-C-5809 CIRCUIT BREAKER 6 EA NS

5925-00-121-9847 Demil Restrictions 5925-00-121-9847

DEMIL: A | DEMILI: 1 | CRITICALITY: X | HMIC: P | PMIC: U | EDC: | ADPEC:

5925-00-121-9847 is a Circuit Breaker that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. The precious metals content of this item is unknown.

5925-00-121-9847 HTS and ScheduleB Import and Export 5925-00-121-9847

5925-00-121-9847 End Users End Users 5925-00-121-9847

US Army (A918)
Effective Date:
1 Apr 2006
Former MOE Rule:
A196
Supplementary Receivers:
CLCT
US Air Force (FXGX)
Effective Date:
1 Apr 2006
Former MOE Rule:
FXTX
NASA (G940)
Effective Date:
1 Apr 1991
US Marine Corps (MC49)
Effective Date:
1 Apr 2006
Former MOE Rule:
MC13
US Navy (N9BN)
Effective Date:
1 Apr 2006
Former MOE Rule:
N9ND
Supplementary Collaborators:
GTKEHD
Poland (WP01)
Effective Date:
1 Jul 2004
Brazil (YA01)
Effective Date:
1 Dec 1999
Spain (YB01)
Effective Date:
1 Apr 1991
Columbia (YC01)
Effective Date:
1 Jul 2015
Singapore (YJ01)
Effective Date:
1 Dec 1994
Australia (ZA01)
Effective Date:
1 Apr 1991
Canada (ZC01)
Effective Date:
1 Apr 1991
New Zealand (ZE01)
Effective Date:
1 Apr 1998
Germany (ZG01)
Effective Date:
1 Apr 1991
Republic of Korea (ZH01)
Effective Date:
1 Apr 1991
Netherlands (ZN01)
Effective Date:
1 Apr 1991
Italy (ZR01)
Effective Date:
1 Dec 2007
Greece (ZU01)
Effective Date:
1 Aug 1995
Turkey (ZW01)
Effective Date:
1 Nov 2005

5925-00-121-9847 Manufacturers Approved Sources 5925-00-121-9847

5925-00-121-9847 Technical Data Datasheet 5925-00-121-9847

Characteristic
Specifications
FIIG
A030A0
Actuator Function [CPRW]
Trip-Reset
Actuator Position Designation [CPRX]
At Pole One
Auxiliary Switch Function And Quantity [CPRZ]
1 Control
Body Length [ADAQ]
0.780 Inches Maximum
Body Width [ADAT]
0.580 Inches Maximum
Bushing Length [ABXD]
0.359 Inches Nominal
Case Material [ADTV]
Metal
Center To Center Distance Between Terminals Parallel To Length [AEBP]
0.593 Inches Nominal
Circuit Protection Type [CPRH]
Overcurrent Single Location
Frequency In Hertz [FREQ]
400.0 Single Location
Maximum Continuous Load Current Rating Per Pole [CPLM]
500.0 Milliamperes Ac Single Location And 500.0 Milliamperes Dc Single Location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps [CPRG]
100.0 Ac Single Location And 100.0 Dc Single Location
Mounting Facility Type And Quantity [AXHR]
1 Threaded Bushing
Mounting Surface To Terminal End Distance [AJWX]
1.420 Inches Maximum
Nominal Thread Size [CQJX]
0.438 Inches
Operating Voltage Type And Rating Per Pole In Volts [CPRF]
115.0 Ac Single Location And 28.0 Dc Single Location
Inclosure Protection Type For Which Designed [CQXF]
Moisture Resistant And Explosion Resistant
Internal Trip Release Configuration [CPSM]
Series Trip Single Location
Main Contact Tripping Mechanism Type [CPRR]
Trip Free
Manual Actuator Type And Quantity [CPRT]
1 Push-Pull
Pole Quantity [AKPX]
1
Reset Method [CPRQ]
Manual
Trip Release Ambient Temp Rating [CRCF]
25.0 Deg Celsius Nominal Single Location
Trip Release Characteristic [CPRL]
Time Delay Single Location
Trip Release Method [CPRJ]
Thermal Single Location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent [CPRN]
145.0 Single Location
Body Style [AAQL]
Specification/Standard Data [ZZZK]
96906-Ms26574 Government Standard
Switch Location And Position Designation [CQSM]
External At Pole One
Switch Terminal Type [CRTK]
Tab, Solder Lug
Switch Voltage Rating And Type In Volts [CSWP]
115.0 Ac And 28.0 Dc
Switch Contact Arrangement [AEGJ]
Single Pole, Single Throw, Normally Closed
Switch Current Rating And Type In Amps [CSSX]
0.5 Ac And 0.5 Dc
Terminal Type And Quantity [TTQY]
2 Screw
Test Data Document [TEST]
81349-Mil-C-5809 Specification (Includes Engineering Type Bulletins, Brochures,Etc., That Reflect Specification Type Data In Specification Format; Excludes Commercial Catalogs, Industry Directories, And Similar Trade Publications, Reflecting General Type Data On Certain Environmental And Performance Requirements And Test Conditions That Are Shown As "Typical", "Average", "Nominal", Etc.).
Thread Quantity Per Inch [CMLP]
32
Thread Series Designator [THSD]
Un
Trip Delay Time In Seconds Per Rated Continuous Current [CQWN]
2.000 Minimum At 200 Pct Single Location And 20.000 Maximum At 200 Pct Single Location

5925-00-121-9847 Weapon Systems (WSDC) Weapon Systems (WSDC) 5925-00-121-9847

5925-00-121-9847 Stock, Inventory and Procurement DLA Procurement Analysis 5925-00-121-9847

Last Stock Position:
62 In Stock
DLA Administrative Lead Time:
Subscribe
DLA Production Lead Time:
Subscribe
Subscribe to View DLA Inventory and Forecast...

5925-00-121-9847 Management Data Management Data 5925-00-121-9847

Effective Date
Organization
Unit of Issue
Unit Price
Qty Unit Pack
Oct 2022
Department of the Army (DA)
EA
Subscribe
1
Oct 2021
Department of the Air Force (DF)
EA
Subscribe
1
Oct 2020
Department of the Air Force (DF)
EA
Subscribe
1
Feb 2020
Department of the Army (DA)
EA
Subscribe
1

Army Army

Materiel Category and Inventory Manager:
Q
Electronics Materiel (DLA/GSA Items)
Appropriation and Budget Activity:
2
Stock Fund Secondary Items
Management Inventory Segment:
2
Non-Repairable Items(Exclusive of Insurance and Provisioning Items)
This code will be used to identify items, which are not reparable.
Weapons System / End Item / Homogeneous Group:
ZZ
Other Munitions/Chemical, Biological, Radiological (CBR) Categories
Multi-application Munitions/CBR Components and Parts
Accounting Requirements:
X
Expendable item.An item of Army property coded with an ARC of X in the AMDF. Expendable items require no formal accountability after issue from a stock record account.Commercial and fabricated items similar to items coded X in the AMDF are considered expendable items.

Air Force Air Force

Fund:
SF
Stock fund applicable to items managed for the Air Force by the respective Inventory Control Point
Budget:
9
57X4921.070 - General Support DIV - Air Force decentralized managed expense items (ERRC XB3, XF3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors
Aggregation Code:
EH
ELECTRONIC COMPONENTS
Price Validation Code:
N
The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
The price has not been analyzed or reviewed for accuracy.
ZOP or Standard price challenges are permissible but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ā€œLā€ or ā€œFā€, then it must be evaluated locally where purchased or fabricated.
Expendability
Recoverability
Repairability:
N
Expendable. Condemn at User. Stock Fund (except Munitions).

Navy Navy

Cognizance:
9B
Navy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg

Marine Corps Marine Corps

Stores Account:
1
Stock Fund Account Item
Combat Essentiality:
2
Non-Critical Repair Part
Echelon Management:
B2
Material Identification:
K
Reserved
Operational Test:
No Special Procedures

5925-00-121-9847 Related Items NATO Stock Numbers Related to 5925-00-121-9847

5925-00-121-9847 Freight Data Freight Information 5925-00-121-9847

5925-00-121-9847 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 061300. A Sub NMFC of X. It has a NMFC Description of CIRCUIT BREAKER/SWITCH NOI. 5925-00-121-9847 is rated as class 77.5 when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 34410 which rates the freight between FCL and LCL. 5925-00-121-9847 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 658 for ocean manifesting and military sealift. 5925-00-121-9847 is not classified as a special type of cargo when transported by water. 5925-00-121-9847 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.

5925-00-121-9847 Packaging Data Packaging Data 5925-00-121-9847

Responsible Activity
Packaging Data Source
Primary Inventory Control Activity (PICA)
--

Item Pack Level (Unpackaged)

Item Size
Item Weight
Characteristics
Weight/Dimensions Category
Fragility
Item Preservation
--
--
--
Over 10lb
Less than 85G
No Requirement

Unit Pack Level (Packaged)

Quantity per Pack
Unit Size
Unit Weight
Unit Cube
Preservation Method
Cleaning/Drying
1
4.0" H x 4.0" W x 1.0" L
--
--
--
Any Suitable Process
Preservation Material
Wrapping Material
Cushioning/Dunnage
Cushioning Thickness
Container
Special Marking
No Requirement
No Requirement
No Requirement
--
No Requirement
No special marking

Intermediate Pack Level

Quantity of Unit Packs
Container
Any Suitable Fiber Box

5925-00-121-9847 Procurement History Procurement History 5925-00-121-9847 1 Records

Contract
Date
CAGE
Quantity
Net Price
Std Price
SPE7M118P0424
30 Oct 2017
Subscribe
77
Subscribe
Subscribe

5925-00-121-9847 Contracting Technical Data File (CTDF) Contracting Technical Data File (CTDF) 5925-00-121-9847 October 2021

Criticality and Quality

Critical Item Code:
Flight Safety:
Life Support:
Certified Samples:
Serialization:
First Article Test (FAT):
Certificate of Quality Compliance:
Production Lot Testing:
Special Testing:
Qualified Products List (QPL):

Commercial Properties

Government Furnished Material:
Government Furnished Tooling:
Government Furnished Property:
Price Evaluation Code:
Diminshing Manufacturing Sources:
Warranty:
Commerical Off The Shelf (COTS):
End Item Application:
Auctioning Candidate:
Source of Procurement:
Contract Option:

Restrictions

Boeing Rights Guard:
Export Controlled:
Controlled Technical Data Package (TDP):
Restricted Technical Data Package (TDP):
Contains Classified Material
Weapons System Indicator Code (WSIC):
F

Packaging Requirements

Packaging Determination Table:
Packaging Review Code:
N
Special Packaging Instruction Number (SPIN):
Special Packaging Instruction Number Revision:
Special Packaging Instruction Number Date:
Pallet Reference Number Required: