Premium Information is available for this item - Upgrade for $1 a day
5915-01-370-5971
Radio Frequency Interference Filter
5915013705971 013705971 GF56402-3 F-12667 6010209-003
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE. View more Radio Frequency Interference Filter
May 2023
13
Marketplace 5915-01-370-5971
Request a Quotation from participating marketplace vendors
Related Documents 5915-01-370-5971 5+ Documents (More...)
Radio Frequency Interference Filter 5915-01-370-5971 5915013705971 013705971 is an item designed
Radio Frequency Interference Filter 5915-01-370-5971 5915013705971 013705971 is an item designed
Restrictions 5915-01-370-5971
5915-01-370-5971 is a Radio Frequency Interference Filter that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. This item does not contain a precious metal.
Import and Export 5915-01-370-5971
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 5915-01-370-5971
- US Air Force (FXGX)
- Effective Date:
- 1 Jun 2006
- Former MOE Rule:
- FXTX
- Poland (WP01)
- Effective Date:
- 1 Sep 2007
- Belgium (ZB01)
- Effective Date:
- 1 Apr 1996
- Republic of Korea (ZH01)
- Effective Date:
- 1 Apr 2008
- Netherlands (ZN01)
- Effective Date:
- 1 Jun 1995
- Norway (ZT01)
- Effective Date:
- 1 Nov 1995
- Greece (ZU01)
- Effective Date:
- 1 May 2008
Approved Sources 5915-01-370-5971
- Part Number
- Manufacturer
- Status
- GF56402-3
- Manufacturer
- 07294 - Genisco Filter Corp (Active)
- Primary Buy
- Primary Buy
- F-12667
- 0AM43 - Lcr Electronics, Inc (Active)
- Secondary Buy
- Secondary Buy
- GF56402-3
- 13050 - Spectrum Control, Inc. (Active)
- Canceled/Obsolete
- Canceled/Obsolete
- 6010209-003
- 12436 - Bae Systems Information And (Active)
- Vendor Drawing
- Vendor Drawing
Datasheet 5915-01-370-5971
- Characteristic
- Specifications
- FIIG
- Specifications
- A047B0
- Body Outside Diameter [ADAR]
- 1.750 Inches Nominal
- Features Provided [CBBL]
- Humidity Proof
- Functional Terminal Type And Quantity [CQDW]
- 1 Circular Flange Input 1St Function1 Circular Flange Output 2Nd Function1 Tab W/Screw Ground 3Rd Function
- Mounting Facility Screw Thread Series Designator [AKEJ]
- Unef
- Mounting Facility Type And Quantity [AXHR]
- 1 Threaded Bushing
- Nominal Thread Size [CQJX]
- 0.750 Inches
- Operating Current Rating Per Function In Amps [AHBC]
- 30.0 Blank
- Operating Temp Range [AFGA]
- +0.0/+85.0 Deg Celsius
- Operating Voltage Rating And Type Per Function [CQGC]
- 250.0 Volts Ac Blank And 600.0 Volts Dc Blank
- Inclosure Type [AKNA]
- Encased
- Power Line Frequency Rating Per Function In Hertz [AHBB]
- 60.0 Blank
- Overall Length [ABHP]
- 6.650 Inches Nominal
- Style Designator [STYL]
- Round Terminal/Terminals On Opposite Surfaces
Weapon Systems (WSDC) 5915-01-370-5971
DLA Procurement Analysis 5915-01-370-5971
Management Data 5915-01-370-5971
Air Force
- Fund:
- SF
- Stock fund applicable to items managed for the Air Force by the respective Inventory Control Point
- Budget:
- 9
- 57X4921.070 - General Support DIV - Air Force decentralized managed expense items (ERRC XB3, XF3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors
- Aggregation Code:
- EH
- ELECTRONIC COMPONENTS
- Price Validation Code:
- N
- The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
The price has not been analyzed or reviewed for accuracy.
ZOP or Standard price challenges are permissible but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of āLā or āFā, then it must be evaluated locally where purchased or fabricated.
- Expendability
Recoverability
Repairability: - N
- Expendable. Condemn at User. Stock Fund (except Munitions).
NATO Stock Numbers Related to 5915-01-370-5971
Freight Information 5915-01-370-5971
5915-01-370-5971 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 061990. A Sub NMFC of X. It has a NMFC Description of ELECTRICAL EQUIP:FILTERS. 5915-01-370-5971 is rated as class 77.5 when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 58500 which rates the freight between FCL and LCL. 5915-01-370-5971 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 72D for ocean manifesting and military sealift. 5915-01-370-5971 is not classified as a special type of cargo when transported by water. 5915-01-370-5971 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.
Packaging Data 5915-01-370-5971
- Responsible Activity
- Packaging Data Source
- Primary Inventory Control Activity (PICA)
- --
Item Pack Level (Unpackaged)
- Item Size
- Item Weight
- Characteristics
- Weight/Dimensions Category
- Fragility
- Item Preservation
- Item Weight
- --
- --
- --
- 0.25 lb or less, one dimension 2" or less, other dimensions less than 24"
- 85 to 110G
- No Requirement
- --
Unit Pack Level (Packaged)
- Quantity per Pack
- Unit Size
- Unit Weight
- Unit Cube
- Preservation Method
- Cleaning/Drying
- Unit Size
- 1
- --
- --
- --
- --
- Any Suitable Process
- --
- Preservation Material
- Wrapping Material
- Cushioning/Dunnage
- Cushioning Thickness
- Container
- Special Marking
- Wrapping Material
- No Requirement
- No Requirement
- PPP-C-795, Cellular Plastic Film Cushioning; or A-A-3129, Open Cell Plastic Cushioning; or PPP-C-1797, Polypropylene Foam Cushioning; or A-A-59136, Polyethylene Foam Cushioning
- --
- PPP-B-566, PPP-B-676, or ASTM-D5118, Folding, Setup or Fiberboard Box
- No special marking
- No Requirement
Intermediate Pack Level
- Quantity of Unit Packs
- Container
- See Method of Preservation
- --
Procurement History 5915-01-370-5971 3 Records
Contracting Technical Data File (CTDF) 5915-01-370-5971 October 2021
Criticality and Quality
- Critical Item Code:
- Flight Safety:
- Life Support:
- Certified Samples:
- Serialization:
- First Article Test (FAT):
- Certificate of Quality Compliance:
- Production Lot Testing:
- Special Testing:
- Qualified Products List (QPL):
Commercial Properties
- Government Furnished Material:
- Government Furnished Tooling:
- Government Furnished Property:
- Price Evaluation Code:
- Diminshing Manufacturing Sources:
- Warranty:
- Commerical Off The Shelf (COTS):
- End Item Application:
- Auctioning Candidate:
- Source of Procurement:
- Contract Option:
Restrictions
- Boeing Rights Guard:
- Export Controlled:
- Controlled Technical Data Package (TDP):
- Restricted Technical Data Package (TDP):
- Contains Classified Material
- Weapons System Indicator Code (WSIC):
- R
Packaging Requirements
- Packaging Determination Table:
- Packaging Review Code:
- Special Packaging Instruction Number (SPIN):
- Special Packaging Instruction Number Revision:
- Special Packaging Instruction Number Date:
- Pallet Reference Number Required: