5915-01-158-1091

Radio Frequency Interference Filter

5915011581091 011581091 5189010-011 81019-24-61PX 452-40024-61PX(100) 5915PL0954508

An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE. View more Radio Frequency Interference Filter

5915-01-158-1091 FILTER,RADIO FREQUENCY INTERFERENCE 5915011581091 011581091

Managed by United States
NSN Created on 18 Jul 1983
Data Last Changed
May 2023
NATO Update Count
24
NATO Data Quality
STYL Style 46 for 5915-01-158-1091 1/1
NSN 5915-01-158-1091 (Identification) 1/1

5915-01-158-1091 Stock and Availability Marketplace 5915-01-158-1091

5915-01-158-1091 Related Documents Related Documents 5915-01-158-1091 2+ Documents (More...)

158-1090 Radio Frequency Interference Filter 5189010-010RNCC: 5 | RNVC: 9 | DAC: 5 18 Jul 1983 5915-01-158-1091
Radio Frequency Interference Filter 452-40024-61PW(100)RNCC: 5 | RNVC: 2 | DAC: 5 18 Jul 1983 5915-01-158-1091
Radio Frequency Interference Filter 452-40024-61PX(100)RNCC: 5 | RNVC: 2 | DAC: 5 18 Jul 1983 5915

5915-01-158-1091 Demil Restrictions 5915-01-158-1091

DEMIL: D | DEMILI: 1 | CRITICALITY: X | HMIC: P | PMIC: S | EDC: | ADPEC:

5915-01-158-1091 is a Radio Frequency Interference Filter that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is a US Munitions List or Commerce Control List Item which must be destroyed to prevent restoration or repair. Only authorized parties may possess this item. This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. This item contains Silver.

5915-01-158-1091 HTS and ScheduleB Import and Export 5915-01-158-1091

5915-01-158-1091 End Users End Users 5915-01-158-1091

US Navy (N9BN)
Effective Date:
1 Jun 2006
Former MOE Rule:
N9ND
Supplementary Collaborators:
GTHD
Poland (WP01)
Effective Date:
1 Mar 2004
Brazil (YA01)
Effective Date:
1 Dec 2001
Spain (YB01)
Effective Date:
1 May 1997
Malaysia (YW01)
Effective Date:
1 Jun 1996
Australia (ZA01)
Effective Date:
1 Apr 1991
Canada (ZC01)
Effective Date:
1 Apr 1991
Germany (ZG01)
Effective Date:
1 Apr 1991
Greece (ZU01)
Effective Date:
1 Jul 2005
Turkey (ZW01)
Effective Date:
1 Nov 1998

5915-01-158-1091 Manufacturers Approved Sources 5915-01-158-1091

5915-01-158-1091 Technical Data Datasheet 5915-01-158-1091

Characteristic
Specifications
FIIG
A047B0
Body Material [CQRG]
Aluminum
Body Surface Treatment [CRST]
Cadmium
Features Provided [CBBL]
Moisture Resistant And Shock Resistant
Functional Terminal Type And Quantity [CQDW]
61 Friction W/Grounding Strap And Pin Input-Output
Maximum Dielectric Withstanding Dc Voltage [CRDC]
1.5 Kilovolts At Sea Level
Maximum Voltage Drop Per Function [AHBE]
2.5 Volts Ac 1St Radio Interference And 8.0 Volts Dc 1St Radio Interference
Maximum Voltage Drop Per Function [AHBE]
2.5 Volts Ac 2Nd Radio Interference And 8.0 Volts Dc 2Nd Radio Interference
Maximum Voltage Drop Per Function [AHBE]
2.5 Volts Ac 3Rd Radio Interference And 8.0 Volts Dc 3Rd Radio Interference
Maximum Voltage Drop Per Function [AHBE]
2.5 Volts Ac 4Th Radio Interference And 8.0 Volts Dc 4Th Radio Interference
Maximum Voltage Drop Per Function [AHBE]
2.5 Volts Ac 5Th Radio Interference And 8.0 Volts Dc 5Th Radio Interference
Maximum Voltage Drop Per Function [AHBE]
2.5 Volts Ac 6Th Radio Interference And 8.0 Volts Dc 6Th Radio Interference
Maximum Temp Rise [AHCG]
25.0 Deg Celsius
Mounting Facility Screw Thread Series Designator [AKEJ]
Unef
Mounting Facility Type And Quantity [AXHR]
1 Threaded Bushing
Nominal Thread Size [CQJX]
1.625 Inches
Operating Current Rating Per Function In Amps [AHBC]
5.0 1St Radio Interference
Operating Current Rating Per Function In Amps [AHBC]
5.0 2Nd Radio Interference
Operating Current Rating Per Function In Amps [AHBC]
5.0 3Rd Radio Interference
Operating Current Rating Per Function In Amps [AHBC]
5.0 4Th Radio Interference
Operating Current Rating Per Function In Amps [AHBC]
5.0 5Th Radio Interference
Operating Current Rating Per Function In Amps [AHBC]
5.0 6Th Radio Interference
Operating Temp Range [AFGA]
-55.0/+125.0 Deg Celsius
Operating Voltage Rating And Type Per Function [CQGC]
250.0 Volts Ac 1St Radio Interference 1St Function And 800.0 Volts Dc 1St Radio Interference 1St Function
Operating Voltage Rating And Type Per Function [CQGC]
250.0 Volts Ac 2Nd Radio Interference 2Nd Function And 800.0 Volts Dc 2Nd Radio Interference 2Nd Function
Operating Voltage Rating And Type Per Function [CQGC]
250.0 Volts Ac 5Th Radio Interference 5Th Function And 800.0 Volts Dc 5Th Radio Interference 5Th Function
Operating Voltage Rating And Type Per Function [CQGC]
250.0 Volts Ac 6Th Radio Interference 6Th Function And 800.0 Volts Dc 6Th Radio Interference 6Th Function
Operating Voltage Rating And Type Per Function [CQGC]
250.0 Volts Ac 3Rd Radio Interference 3Rd Function And 800.0 Volts Dc 3Rd Radio Interference 3Rd Function
Operating Voltage Rating And Type Per Function [CQGC]
250.0 Volts Ac 4Th Radio Interference 4Th Function And 800.0 Volts Dc 4Th Radio Interference 4Th Function
Output Terminal Identification [AHBT]
Mil-C-26482
Output Terminal Manufacturer Code [AHBS]
11139
Inclosure Type [AKNA]
Hermetically Sealed
Input Terminal Identification [AHBP]
Mil-C-26482
Input Terminal Manufacturer Code [AHBN]
11139
Load Impedance Per Function [AHAS]
50.0 Ohms 1St Radio Interference
Load Impedance Per Function [AHAS]
50.0 Ohms 2Nd Radio Interference
Load Impedance Per Function [AHAS]
50.0 Ohms 5Th Radio Interference
Load Impedance Per Function [AHAS]
50.0 Ohms 6Th Radio Interference
Load Impedance Per Function [AHAS]
50.0 Ohms 3Rd Radio Interference
Load Impedance Per Function [AHAS]
50.0 Ohms 4Th Radio Interference
Power Line Frequency Rating Per Function In Hertz [AHBB]
400.0 1St Radio Interference
Power Line Frequency Rating Per Function In Hertz [AHBB]
400.0 6Th Radio Interference
Power Line Frequency Rating Per Function In Hertz [AHBB]
400.0 2Nd Radio Interference
Power Line Frequency Rating Per Function In Hertz [AHBB]
400.0 3Rd Radio Interference
Power Line Frequency Rating Per Function In Hertz [AHBB]
400.0 4Th Radio Interference
Power Line Frequency Rating Per Function In Hertz [AHBB]
400.0 5Th Radio Interference
Precious Material And Location [PMLC]
Contact Surfaces Silver
Precious Material [PRMT]
Silver
Principal Circuitry Type Per Function [AHBL]
Inductance-Capacitance 1St Radio Interference
Principal Circuitry Type Per Function [AHBL]
Inductance-Capacitance 3Rd Radio Interference
Principal Circuitry Type Per Function [AHBL]
Inductance-Capacitance 2Nd Radio Interference
Principal Circuitry Type Per Function [AHBL]
Inductance-Capacitance 5Th Radio Interference
Principal Circuitry Type Per Function [AHBL]
Inductance-Capacitance 6Th Radio Interference
Principal Circuitry Type Per Function [AHBL]
Inductance-Capacitance 4Th Radio Interference
Source Impedance Rating Per Function [AHAQ]
50.0 Ohms 1St Radio Interference
Source Impedance Rating Per Function [AHAQ]
50.0 Ohms 4Th Radio Interference
Source Impedance Rating Per Function [AHAQ]
50.0 Ohms 2Nd Radio Interference
Source Impedance Rating Per Function [AHAQ]
50.0 Ohms 3Rd Radio Interference
Source Impedance Rating Per Function [AHAQ]
50.0 Ohms 5Th Radio Interference
Source Impedance Rating Per Function [AHAQ]
50.0 Ohms 6Th Radio Interference
Overall Height [ABKW]
1.796 Inches Minimum And 1.828 Inches Maximum
Overall Length [ABHP]
2.264 Inches Minimum
Overall Width [ABMK]
1.796 Inches Minimum And 1.828 Inches Maximum
Special Features [FEAT]
Sixty-One Filtered Functions
Vibration Resistance Range In Hertz [AECR]
+10.0/+500.0
Style Designator [STYL]
Filter Connector

5915-01-158-1091 Weapon Systems (WSDC) Weapon Systems (WSDC) 5915-01-158-1091

5915-01-158-1091 Stock, Inventory and Procurement DLA Procurement Analysis 5915-01-158-1091

DLA Administrative Lead Time:
Subscribe
DLA Production Lead Time:
Subscribe
Subscribe to View DLA Inventory and Forecast...

5915-01-158-1091 Management Data Management Data 5915-01-158-1091

Effective Date
Organization
Unit of Issue
Unit Price
Qty Unit Pack
Mar 2023
Defense Logistics Agency (DS)
EA
Subscribe
1
Oct 2021
Department of the Navy (DN)
EA
Subscribe
1
Oct 2020
Department of the Navy (DN)
EA
Subscribe
1
Feb 2020
Department of the Navy (DN)
EA
Subscribe
1
MOE
USC
Code
Statement
Order of Use
Jump To Code
Qty Per Assy
UOM
Technical Document
Quantative Expression
Department of the Navy (DN)
N
X
Formerly 5935
Defense Logistics Agency (DS)
I
X
Formerly 5935

Navy Navy

Cognizance:
9B
Navy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg

5915-01-158-1091 Related Items NATO Stock Numbers Related to 5915-01-158-1091

5915-01-158-1091 Freight Data Freight Information 5915-01-158-1091

5915-01-158-1091 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 061990. A Sub NMFC of X. It has a NMFC Description of ELECTRICAL EQUIP:FILTERS. 5915-01-158-1091 is rated as class 77.5 when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 58500 which rates the freight between FCL and LCL. 5915-01-158-1091 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 72D for ocean manifesting and military sealift. 5915-01-158-1091 is not classified as a special type of cargo when transported by water. 5915-01-158-1091 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.

5915-01-158-1091 Packaging Data Packaging Data 5915-01-158-1091

Responsible Activity
Packaging Data Source
Primary Inventory Control Activity (PICA)
--

Item Pack Level (Unpackaged)

Item Size
Item Weight
Characteristics
Weight/Dimensions Category
Fragility
Item Preservation
--
--
--
0.25 lb or less, one dimension 2" or less, other dimensions less than 24"
85 to 110G
No Requirement

Unit Pack Level (Packaged)

Quantity per Pack
Unit Size
Unit Weight
Unit Cube
Preservation Method
Cleaning/Drying
1
--
--
--
--
--
Preservation Material
Wrapping Material
Cushioning/Dunnage
Cushioning Thickness
Container
Special Marking
--
--
--
--
--
No special marking

Intermediate Pack Level

Quantity of Unit Packs
Container
See Method of Preservation
--

5915-01-158-1091 Contracting Technical Data File (CTDF) Contracting Technical Data File (CTDF) 5915-01-158-1091 October 2021

Criticality and Quality

Critical Item Code:
Flight Safety:
Life Support:
Certified Samples:
Serialization:
First Article Test (FAT):
Certificate of Quality Compliance:
Production Lot Testing:
Special Testing:
Qualified Products List (QPL):

Commercial Properties

Government Furnished Material:
Government Furnished Tooling:
Government Furnished Property:
Price Evaluation Code:
Diminshing Manufacturing Sources:
Warranty:
Commerical Off The Shelf (COTS):
End Item Application:
Auctioning Candidate:
Source of Procurement:
Contract Option:

Restrictions

Boeing Rights Guard:
Export Controlled:
Controlled Technical Data Package (TDP):
Restricted Technical Data Package (TDP):
Contains Classified Material
Weapons System Indicator Code (WSIC):
L

Packaging Requirements

Packaging Determination Table:
Packaging Review Code:
Special Packaging Instruction Number (SPIN):
Special Packaging Instruction Number Revision:
Special Packaging Instruction Number Date:
Pallet Reference Number Required: