5915-01-025-0859
Radio Frequency Interference Filter
5915010250859 010250859 905559-1 10 B 614 RF15412 GF-55625
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE. View more Radio Frequency Interference Filter
![]()
May 2023
7

Marketplace 5915-01-025-0859
Request a Quotation from participating marketplace vendors
Related Documents 5915-01-025-0859 2+ Documents (More...)
5915-01-025-0859 BUY NE FedMall Updated Every Day 5915-01-025-0859 RQST NE Updated Every Day 5915-01
-025-0859 RQST Updated Every Day 5915-01-025-0859 RQST NE Related Documents 5915-01-025-0859 2+ Documents
Filter Upgrade your Account Upgrade 5915-01-025-0859Radio Frequency Interference Filter5915010250859 010250859
905559 https//www.nsnlookup.com /fsg-59/fsc-5915/us 5915-01-025-0859 Radio Frequency Interference Filter
Restrictions 5915-01-025-0859
5915-01-025-0859 is a Radio Frequency Interference Filter that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. This item has been confirmed as a Critical Munitions List Item or a Sensitive Commerce Control List Item and cannot be in the possession of any party anywhere in the World who is not an authorized NATO Government. Any other possessor of this item should mutilate it now as possession violates international and local laws. This item is a confirmed Commerce Control List Item (CCLI). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. The precious metals content of this item is unknown.
Import and Export 5915-01-025-0859
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 5915-01-025-0859
- US Navy (N9BN)
- Effective Date:
- 1 Jun 2006
- Former MOE Rule:
- N9ND
- Supplementary Collaborators:
- GTHD
Approved Sources 5915-01-025-0859
- Part Number
- Manufacturer
- Status
- 905559-1
- Manufacturer
- 06481 - Northrop Grumman Systems Corporation (Active)
- Primary Buy
- Primary Buy
- 10 B 614
- 13058 - Sora Power Inc. (Active)
- Secondary Buy
- Secondary Buy
- RF15412
- 13619 - Ems Development Corporation (Active)
- Secondary Buy
- Secondary Buy
- GF-55625
- 13050 - Spectrum Control, Inc. (Active)
- Canceled/Obsolete
- Canceled/Obsolete
- GF-55625
- 07294 - Genisco Filter Corp (Active)
- Canceled/Obsolete
- Canceled/Obsolete
Datasheet 5915-01-025-0859
- Characteristic
- Specifications
- FIIG
- Specifications
- A047B0
- Body Length [ADAQ]
- 7.500 Inches Maximum
- Body Material [CQRG]
- Metal
- Body Width [ADAT]
- 6.940 Inches Minimum And 7.060 Inches Maximum
- Distance Between Centerlines Of Mounting Facilities Parallel To Body Length [AEBY]
- 8.125 Inches Nominal
- Distance Between Centerlines Of Mounting Facilities Parallel To Body Width [AEHA]
- 6.125 Inches Nominal
- Functional Terminal Type And Quantity [CQDW]
- 2 Threaded Stud Ground 3Rd Function
- Functional Terminal Type And Quantity [CQDW]
- 5 Threaded Stud Input 1St Function
- Functional Terminal Type And Quantity [CQDW]
- 5 Threaded Stud Output 2Nd Function
- Maximum Dielectric Withstanding Dc Voltage [CRDC]
- 600.0 Volts At Sea Level
- Maximum Voltage Drop Per Function [AHBE]
- 2.5 Volts Ac 1St Radio Interference
- Maximum Voltage Drop Per Function [AHBE]
- 2.5 Volts Ac 2Nd Radio Interference
- Maximum Voltage Drop Per Function [AHBE]
- 2.5 Volts Ac 3Rd Radio Interference
- Maximum Voltage Drop Per Function [AHBE]
- 500.0 Millivolts Dc 4Th Radio Interference
- Maximum Voltage Drop Per Function [AHBE]
- 500.0 Millivolts Dc 5Th Radio Interference
- Maximum Temp Rise [AHCG]
- 45.0 Deg Celsius
- Mounting Facility Type And Quantity [AXHR]
- 6 Unthreaded Hole
- Operating Current Rating Per Function In Amps [AHBC]
- 32.6 1St Radio Interference
- Operating Current Rating Per Function In Amps [AHBC]
- 32.6 2Nd Radio Interference
- Operating Current Rating Per Function In Amps [AHBC]
- 32.6 3Rd Radio Interference
- Operating Current Rating Per Function In Amps [AHBC]
- 42.0 4Th Radio Interference
- Operating Current Rating Per Function In Amps [AHBC]
- 42.0 5Th Radio Interference
- Operating Temp Range [AFGA]
- -55.0/+78.0 Deg Celsius
- Operating Voltage Rating And Type Per Function [CQGC]
- 115.0 Volts Ac 1St Radio Interference 1St Function
- Operating Voltage Rating And Type Per Function [CQGC]
- 115.0 Volts Ac 2Nd Radio Interference 2Nd Function
- Operating Voltage Rating And Type Per Function [CQGC]
- 115.0 Volts Ac 3Rd Radio Interference 3Rd Function
- Operating Voltage Rating And Type Per Function [CQGC]
- 150.0 Volts Dc 4Th Radio Interference 4Th Function
- Operating Voltage Rating And Type Per Function [CQGC]
- 150.0 Volts Dc 5Th Radio Interference 5Th Function
- Inclosure Type [AKNA]
- Hermetically Sealed
- Load Impedance Per Function [AHAS]
- 50.0 Ohms 1St Radio Interference
- Load Impedance Per Function [AHAS]
- 50.0 Ohms 3Rd Radio Interference
- Load Impedance Per Function [AHAS]
- 50.0 Ohms 2Nd Radio Interference
- Load Impedance Per Function [AHAS]
- 50.0 Ohms 4Th Radio Interference
- Load Impedance Per Function [AHAS]
- 50.0 Ohms 5Th Radio Interference
- Power Line Frequency Rating Per Function In Hertz [AHBB]
- 60.0 1St Radio Interference
- Power Line Frequency Rating Per Function In Hertz [AHBB]
- 60.0 2Nd Radio Interference
- Power Line Frequency Rating Per Function In Hertz [AHBB]
- 60.0 3Rd Radio Interference
- Source Impedance Rating Per Function [AHAQ]
- 50.0 Ohms 1St Radio Interference
- Source Impedance Rating Per Function [AHAQ]
- 50.0 Ohms 3Rd Radio Interference
- Source Impedance Rating Per Function [AHAQ]
- 50.0 Ohms 2Nd Radio Interference
- Source Impedance Rating Per Function [AHAQ]
- 50.0 Ohms 4Th Radio Interference
- Source Impedance Rating Per Function [AHAQ]
- 50.0 Ohms 5Th Radio Interference
- Overall Height [ABKW]
- 3.000 Inches Maximum
- Overall Length [ABHP]
- 9.500 Inches Maximum
- Unpackaged Unit Weight [PKWT]
- 20.000 Pounds
- Unthreaded Mounting Hole Diameter [AEBV]
- 0.218 Inches Minimum And 0.224 Inches Maximum
- Style Designator [STYL]
- Rectangular Terminal/Terminals On Opposite Surfaces
Weapon Systems (WSDC) 5915-01-025-0859
DLA Procurement Analysis 5915-01-025-0859
Management Data 5915-01-025-0859
Navy
- Cognizance:
- 9B
- Navy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Similar Supply Items to 5915-01-025-0859


















Freight Information 5915-01-025-0859
5915-01-025-0859 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 061990. A Sub NMFC of X. It has a NMFC Description of ELECTRICAL EQUIP:FILTERS. 5915-01-025-0859 is rated as class 77.5 when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 58500 which rates the freight between FCL and LCL. 5915-01-025-0859 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 72D for ocean manifesting and military sealift. 5915-01-025-0859 is not classified as a special type of cargo when transported by water. 5915-01-025-0859 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.
Packaging Data 5915-01-025-0859
- Responsible Activity
- Packaging Data Source
- Primary Inventory Control Activity (PICA)
- --
Item Pack Level (Unpackaged)
- Item Size
- Item Weight
- Characteristics
- Weight/Dimensions Category
- Fragility
- Item Preservation
- Item Weight
- --
- --
- Electrical Instrument
- 0.25 lb or less, one dimension 2" or less, other dimensions less than 24"
- 85 to 110G
- No Requirement
- --
Unit Pack Level (Packaged)
- Quantity per Pack
- Unit Size
- Unit Weight
- Unit Cube
- Preservation Method
- Cleaning/Drying
- Unit Size
- 1
- --
- --
- --
- Physical Protection
- Any Suitable Process
- --
- Preservation Material
- Wrapping Material
- Cushioning/Dunnage
- Cushioning Thickness
- Container
- Special Marking
- Wrapping Material
- No Requirement
- No Requirement
- ASTM-D4727, Fiberboard used as Pads, Cells, Die-cuts or Sleeves
- --
- ASTM-D5118, Type CF, Class Domestic, Corrugated Fiberboard Box
- No special marking
- No Requirement
Intermediate Pack Level
- Quantity of Unit Packs
- Container
- Any Suitable Fiber Box
Contracting Technical Data File (CTDF) 5915-01-025-0859 October 2021
Criticality and Quality
- Critical Item Code:
- Flight Safety:
- Life Support:
- Certified Samples:
- Serialization:
- First Article Test (FAT):
- Certificate of Quality Compliance:
- Production Lot Testing:
- Special Testing:
- Qualified Products List (QPL):
Commercial Properties
- Government Furnished Material:
- Government Furnished Tooling:
- Government Furnished Property:
- Price Evaluation Code:
- Diminshing Manufacturing Sources:
- Warranty:
- Commerical Off The Shelf (COTS):
- End Item Application:
- Auctioning Candidate:
- Source of Procurement:
- Contract Option:
Restrictions
- Boeing Rights Guard:
- Export Controlled:
- Controlled Technical Data Package (TDP):
- Restricted Technical Data Package (TDP):
- Contains Classified Material
- Weapons System Indicator Code (WSIC):
- J
Packaging Requirements
- Packaging Determination Table:
- Packaging Review Code:
- Special Packaging Instruction Number (SPIN):
- Special Packaging Instruction Number Revision:
- Special Packaging Instruction Number Date:
- Pallet Reference Number Required: