Premium Information is available for this item - Upgrade for $1 a day

5915-00-628-8321

Radio Frequency Interference Filter

5915006288321 006288321 GF8171 G300197S1 M1531 FC2634

An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE. View more Radio Frequency Interference Filter

5915-00-628-8321 FILTER,RADIO FREQUENCY INTERFERENCE 5915006288321 006288321

Managed by United States
NSN Created on 12 Mar 1975
Data Last Changed
May 2023
NATO Update Count
8
NATO Data Quality
STYL Style 30 for 5915-00-628-8321 1/1
NSN 5915-00-628-8321 (Identification) 1/1

5915-00-628-8321 Stock and Availability Marketplace 5915-00-628-8321

5915-00-628-8321 Related Documents Related Documents 5915-00-628-8321 5+ Documents (More...)

Account Upgrade 4820-00-656-4831Directional Control Linear Valve Sleeve And Slide4820006564831 006564831 M1531
M1531 SLEEVE AND SLIDE,DIRECTIONAL CONTROL LINEAR VALVE 103 EA NS Request Quotation Updated Every Day
day Upgrade your Account Upgrade 6625-00-565-0120Ammeter6625005650120 005650120 8519153 G243593-1 M1531
day Upgrade your Account Upgrade 6625-00-565-0120Ammeter6625005650120 005650120 8519153 G243593-1 M1531
Upgrade your Account Upgrade 6625-00-535-9747Arbitrary Scale Meter6625005359747 005359747 8519148 M1531
6625-00-535 https//www.nsnlookup.com /fsg-48/fsc-4820/us 4820-00-656-4831 4820006564831 006564831,M1531
- Upgrade for $1 a day Upgrade your Account Upgrade 6625-00-535-9748Ammeter6625005359748 005359748 M1531
( More... ) https//www.nsnlookup.com /fsg-48/fsc-4820/us 4820-00-656-4831 4820006564831 006564831,M1531
M1531 SLEEVE AND SLIDE,DIRECTIONAL CONTROL LINEAR VALVE 103 EA NS Request Quotation Updated Every Day
Upgrade your Account Upgrade 6625-00-535-9747Arbitrary Scale Meter6625005359747 005359747 8519148 M1531
day Upgrade your Account Upgrade 6625-00-565-0120Ammeter6625005650120 005650120 8519153 G243593-1 M1531
https//www.nsnlookup.com /fsg-48/fsc-4820/us 4820-00-656-4831 4820006564831 006564831,M1531 Account

5915-00-628-8321 Demil Restrictions 5915-00-628-8321

DEMIL: D | DEMILI: 1 | CRITICALITY: X | HMIC: P | PMIC: U | EDC: | ADPEC:

5915-00-628-8321 is a Radio Frequency Interference Filter that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is a US Munitions List or Commerce Control List Item which must be destroyed to prevent restoration or repair. Only authorized parties may possess this item. This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. The precious metals content of this item is unknown.

5915-00-628-8321 HTS and ScheduleB Import and Export 5915-00-628-8321

5915-00-628-8321 End Users End Users 5915-00-628-8321

US Navy (N9BN)
Effective Date:
1 Jun 2006
Former MOE Rule:
N9ND
Supplementary Collaborators:
HD
Spain (YB01)
Effective Date:
1 Apr 1991

5915-00-628-8321 Manufacturers Approved Sources 5915-00-628-8321

5915-00-628-8321 Technical Data Datasheet 5915-00-628-8321

Characteristic
Specifications
FIIG
A047B0
Body Length [ADAQ]
6.900 Inches Nominal
Body Material [CQRG]
Metal
Body Surface Treatment [CRST]
Tin
Body Width [ADAT]
4.700 Inches Nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length [AEBY]
7.437 Inches Nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width [AEHA]
3.500 Inches Nominal
Functional Terminal Type And Quantity [CQDW]
4 Threaded Stud Input 1St Function
Functional Terminal Type And Quantity [CQDW]
4 Threaded Stud Output 2Nd Function
Maximum Dielectric Withstanding Dc Voltage [CRDC]
600.0 Volts At Sea Level
Mounting Facility Type And Quantity [AXHR]
6 Unthreaded Hole
Operating Current Rating Per Function In Amps [AHBC]
15.0 1St Radio Interference
Operating Current Rating Per Function In Amps [AHBC]
15.0 2Nd Radio Interference
Operating Current Rating Per Function In Amps [AHBC]
15.0 3Rd Radio Interference
Operating Current Rating Per Function In Amps [AHBC]
15.0 4Th Radio Interference
Operating Temp Range [AFGA]
-54.0/+65.0 Deg Celsius
Operating Voltage Rating And Type Per Function [CQGC]
120.0 Volts Ac 1St Radio Interference 1St Function
Operating Voltage Rating And Type Per Function [CQGC]
120.0 Volts Ac 3Rd Radio Interference 3Rd Function
Operating Voltage Rating And Type Per Function [CQGC]
120.0 Volts Ac 4Th Radio Interference 4Th Function
Operating Voltage Rating And Type Per Function [CQGC]
120.0 Volts Ac 2Nd Radio Interference 2Nd Function
Inclosure Type [AKNA]
Encased
Load Impedance Per Function [AHAS]
50.0 Ohms 1St Radio Interference
Load Impedance Per Function [AHAS]
50.0 Ohms 2Nd Radio Interference
Load Impedance Per Function [AHAS]
50.0 Ohms 4Th Radio Interference
Load Impedance Per Function [AHAS]
50.0 Ohms 3Rd Radio Interference
Power Line Frequency Rating Per Function In Hertz [AHBB]
400.0 1St Radio Interference
Power Line Frequency Rating Per Function In Hertz [AHBB]
400.0 2Nd Radio Interference
Power Line Frequency Rating Per Function In Hertz [AHBB]
400.0 3Rd Radio Interference
Power Line Frequency Rating Per Function In Hertz [AHBB]
400.0 4Th Radio Interference
Source Impedance Rating Per Function [AHAQ]
50.0 Ohms 1St Radio Interference
Source Impedance Rating Per Function [AHAQ]
50.0 Ohms 3Rd Radio Interference
Source Impedance Rating Per Function [AHAQ]
50.0 Ohms 2Nd Radio Interference
Source Impedance Rating Per Function [AHAQ]
50.0 Ohms 4Th Radio Interference
Overall Height [ABKW]
3.500 Inches Nominal
Overall Length [ABHP]
7.900 Inches Nominal
Unthreaded Mounting Hole Diameter [AEBV]
0.205 Inches Nominal
Vibration Resistance Range In Hertz [AECR]
+10.0/+55.0
Style Designator [STYL]
Rectangular Terminal/Terminals On Opposite Surfaces

5915-00-628-8321 Weapon Systems (WSDC) Weapon Systems (WSDC) 5915-00-628-8321

5915-00-628-8321 Stock, Inventory and Procurement DLA Procurement Analysis 5915-00-628-8321

DLA Administrative Lead Time:
Subscribe
DLA Production Lead Time:
Subscribe
Subscribe to View DLA Inventory and Forecast...

5915-00-628-8321 Management Data Management Data 5915-00-628-8321

Effective Date
Organization
Unit of Issue
Unit Price
Qty Unit Pack
Oct 2022
Department of the Navy (DN)
EA
Subscribe
1
Oct 2021
Department of the Navy (DN)
EA
Subscribe
1
Oct 2020
Department of the Navy (DN)
EA
Subscribe
1
Feb 2020
Department of the Navy (DN)
EA
Subscribe
1

Navy Navy

Cognizance:
9B
Navy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Special Material ID:
BA
Attack

5915-00-628-8321 Related Items NATO Stock Numbers Related to 5915-00-628-8321

5915-00-628-8321 Freight Data Freight Information 5915-00-628-8321

5915-00-628-8321 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 061990. A Sub NMFC of X. It has a NMFC Description of ELECTRICAL EQUIP:FILTERS. 5915-00-628-8321 is rated as class 77.5 when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 58500 which rates the freight between FCL and LCL. 5915-00-628-8321 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 72D for ocean manifesting and military sealift. 5915-00-628-8321 is not classified as a special type of cargo when transported by water. 5915-00-628-8321 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.

5915-00-628-8321 Packaging Data Packaging Data 5915-00-628-8321

Responsible Activity
Packaging Data Source
Primary Inventory Control Activity (PICA)
--

Item Pack Level (Unpackaged)

Item Size
Item Weight
Characteristics
Weight/Dimensions Category
Fragility
Item Preservation
--
--
--
0.25 lb or less, one dimension 2" or less, other dimensions less than 24"
85 to 110G
No Requirement

Unit Pack Level (Packaged)

Quantity per Pack
Unit Size
Unit Weight
Unit Cube
Preservation Method
Cleaning/Drying
1
--
--
--
--
Any Suitable Process
Preservation Material
Wrapping Material
Cushioning/Dunnage
Cushioning Thickness
Container
Special Marking
No Requirement
MIL-DTL-17667, Neutral Wrapping Paper
ASTM-D4727, Fiberboard used as Pads, Cells, Die-cuts or Sleeves
--
ASTM-D5118, Type CF, Class Domestic, Corrugated Fiberboard Box
Method 50

Intermediate Pack Level

Quantity of Unit Packs
Container
Any Suitable Fiber Box

5915-00-628-8321 Contracting Technical Data File (CTDF) Contracting Technical Data File (CTDF) 5915-00-628-8321 October 2021

Criticality and Quality

Critical Item Code:
Flight Safety:
Life Support:
Certified Samples:
Serialization:
First Article Test (FAT):
Certificate of Quality Compliance:
Production Lot Testing:
Special Testing:
Qualified Products List (QPL):

Commercial Properties

Government Furnished Material:
Government Furnished Tooling:
Government Furnished Property:
Price Evaluation Code:
Diminshing Manufacturing Sources:
Warranty:
Commerical Off The Shelf (COTS):
End Item Application:
Auctioning Candidate:
Source of Procurement:
Contract Option:

Restrictions

Boeing Rights Guard:
Export Controlled:
Controlled Technical Data Package (TDP):
Restricted Technical Data Package (TDP):
Contains Classified Material
Weapons System Indicator Code (WSIC):
Y

Packaging Requirements

Packaging Determination Table:
Packaging Review Code:
Special Packaging Instruction Number (SPIN):
Special Packaging Instruction Number Revision:
Special Packaging Instruction Number Date:
Pallet Reference Number Required: