Premium Information is available for this item - Upgrade for $1 a day
5915-00-239-3206
Band Pass Filter
5915002393206 002393206 SMC563349-6 B9-1651-06 CC0451-06 F3092 FL10131-7 CSC19-7R LDFL10131
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified). View more Band Pass Filter
May 2023
5

Marketplace 5915-00-239-3206
Request a Quotation from participating marketplace vendors
Related Documents 5915-00-239-3206 5+ Documents (More...)
F3092 FILTER,BAND PASS RQST NS Request Quotation FedMall Updated Every 15 Minutes 5915-00-239-3206 BUY
NE FedMall Updated Every Day 5915-00-239-3206 RQST NE Updated Every Day 5915-00-239-3206 RQST Updated
LDFL10131 a day Upgrade your Account Upgrade 5915-00-240- https//www.nsnlookup.com /fsg-59/fsc-5915/
us 5915-00-483-5670 https//www.nsnlookup.com /fsg-59/fsc-5915/us 5915-00-239-3206 Band Pass Filter 5915002393206
Band Pass Filter 5915002393206 002393206 Upgrade your Account Upgrade 5915-00-239-3206Band Pass
Filter5915002393206 002393206 SMC563349-6 B9-1651-06 Updated Every Day 5915-00-239-3206 RQST Updated
-6DM963576 F3092-6DBM17 A generator having a characteristic of current and voltage that is continually
www.nsnlookup.com /fsg-61/fsc-6115/de 6115-12-147-5680 Alternating Current Generator 6115121475680 F3092
240-2820 Band Pass Filter 5915002402820002402820 https//www.nsnlookup.com /fsg-59/fsc-5915/us 5915-00-239-3206
Band Pass Filter 5915002393206 002393206 3206Band Pass Filter5915002393206 002393206 SMC563349-
Restrictions 5915-00-239-3206
5915-00-239-3206 is a Band Pass Filter that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. The precious metals content of this item is unknown.
Import and Export 5915-00-239-3206
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 5915-00-239-3206
- US Navy (N9BN)
- Effective Date:
- 1 Jun 2006
- Former MOE Rule:
- N9ND
- Supplementary Collaborators:
- HD
Approved Sources 5915-00-239-3206
- Part Number
- Manufacturer
- Status
- SMC563349-6
- Manufacturer
- 80063 - Us Army Communications & Electronics (Active)
- Primary Buy
- Primary Buy
- B9-1651-06
- 14304 - L3harris Technologies, Inc. (Active)
- Secondary Buy
- Secondary Buy
- CC0451-06
- 32840 - Conolog Corporation (Active)
- Secondary Buy
- Secondary Buy
- F3092
- 72149 - Electronic Transformer Corp (Active)
- Secondary Buy
- Secondary Buy
- FL10131-7
- 10241 - Telephone Systems/Communications (Obsolete)
- Canceled/Obsolete
- Canceled/Obsolete
- CSC19-7R
- 09376 - Omnitec Data Corp (Obsolete)
- Canceled/Obsolete
- Canceled/Obsolete
- LDFL10131
- 10241 - Telephone Systems/Communications (Obsolete)
- Canceled/Obsolete
- Canceled/Obsolete
Datasheet 5915-00-239-3206
- Characteristic
- Specifications
- FIIG
- Specifications
- A047B0
- Body Height [ADAU]
- 6.172 Inches Minimum And 6.204 Inches Maximum
- Body Length [ADAQ]
- 1.484 Inches Minimum And 1.516 Inches Maximum
- Body Material [CQRG]
- Metal
- Body Width [ADAT]
- 1.484 Inches Minimum And 1.516 Inches Maximum
- Discrimination At Specified Frequencies Per Function In Decibels [CRBC]
- 3.0 Minimum Blank And 38.0 Maximum Blank
- Features Provided [CBBL]
- Magnetic Case
- Frequency Band Width Per Function [CRBB]
- 1.02 Kilohertz Blank And 1.19 Kilohertz Blank
- Functional Terminal Type And Quantity [CQDW]
- 1 Standard Tube Base Input-Output/Ground
- Mounting Facility Type And Quantity [AXHR]
- 1 Plug-In
- Operating Temp Range [AFGA]
- -0.0/+50.0 Deg Celsius
- Inclosure Type [AKNA]
- Hermetically Sealed
- Insertion Loss At Reference Frequency Per Function In Decibels [CQDR]
- 3.0 Blank
- Load Impedance Per Function [AHAS]
- 600.0 Ohms Blank
- Principal Circuitry Type Per Function [AHBL]
- Inductance-Capacitance Blank
- Reference Frequency Per Function [AHAJ]
- 1.275 Kilohertz Blank
- Source Impedance Rating Per Function [AHAQ]
- 600.0 Ohms Blank
- Overall Height [ABKW]
- 6.438 Inches Nominal
- Specified Frequencies Of Discrimination Per Function [CQFC]
- 935.00 Hertz Blank And 1.02 Kilohertz Blank And 1.19 Kilohertz Blank And 1.275 Kilohertz Blank
- Style Designator [STYL]
- Rectangular Terminal/Terminals On One Surface
DLA Procurement Analysis 5915-00-239-3206
Management Data 5915-00-239-3206
Navy
- Cognizance:
- 9B
- Navy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Similar Supply Items to 5915-00-239-3206


















Freight Information 5915-00-239-3206
5915-00-239-3206 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 061990. A Sub NMFC of X. It has a NMFC Description of ELECTRICAL EQUIP:FILTERS. 5915-00-239-3206 is rated as class 77.5 when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 58500 which rates the freight between FCL and LCL. 5915-00-239-3206 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 593 for ocean manifesting and military sealift. 5915-00-239-3206 is not classified as a special type of cargo when transported by water. 5915-00-239-3206 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.
Packaging Data 5915-00-239-3206
- Responsible Activity
- Packaging Data Source
- Primary Inventory Control Activity (PICA)
- --
Item Pack Level (Unpackaged)
- Item Size
- Item Weight
- Characteristics
- Weight/Dimensions Category
- Fragility
- Item Preservation
- Item Weight
- --
- --
- Electrical Instrument
- 0.25 lb or less, one dimension 2" or less, other dimensions less than 24"
- 85 to 110G
- No Requirement
- --
Unit Pack Level (Packaged)
- Quantity per Pack
- Unit Size
- Unit Weight
- Unit Cube
- Preservation Method
- Cleaning/Drying
- Unit Size
- 1
- --
- --
- --
- Physical Protection
- Any Suitable Process
- --
- Preservation Material
- Wrapping Material
- Cushioning/Dunnage
- Cushioning Thickness
- Container
- Special Marking
- Wrapping Material
- No Requirement
- No Requirement
- --
- --
- PPP-B-566, PPP-B-676, or ASTM-D5118, Folding, Setup or Fiberboard Box
- No special marking
- No Requirement
Intermediate Pack Level
- Quantity of Unit Packs
- Container
- Any Suitable Fiber Box
Contracting Technical Data File (CTDF) 5915-00-239-3206 October 2021
Criticality and Quality
- Critical Item Code:
- Flight Safety:
- Life Support:
- Certified Samples:
- Serialization:
- First Article Test (FAT):
- Certificate of Quality Compliance:
- Production Lot Testing:
- Special Testing:
- Qualified Products List (QPL):
Commercial Properties
- Government Furnished Material:
- Government Furnished Tooling:
- Government Furnished Property:
- Price Evaluation Code:
- Diminshing Manufacturing Sources:
- Warranty:
- Commerical Off The Shelf (COTS):
- End Item Application:
- Auctioning Candidate:
- Source of Procurement:
- Contract Option:
Restrictions
- Boeing Rights Guard:
- Export Controlled:
- Controlled Technical Data Package (TDP):
- Restricted Technical Data Package (TDP):
- Contains Classified Material
- Weapons System Indicator Code (WSIC):
- N
Packaging Requirements
- Packaging Determination Table:
- Packaging Review Code:
- Special Packaging Instruction Number (SPIN):
- Special Packaging Instruction Number Revision:
- Special Packaging Instruction Number Date:
- Pallet Reference Number Required: