Premium Information is available for this item - Upgrade for $1 a day

5910-01-257-2956

Plastic Dielectric Fixed Capacitor

5910012572956 012572956 MIL-PRF-19978/13 CQR29A1ME684G3P CQR29A1ME684G3M MILC19978-13

A capacitor whose capacitance value cannot be adjusted or varied, having a plastic, plastic film, plasticized (plastic impregnated) paper, or any combination of plastic and paper or plastic and paper films as the dielectric material. The plastic may be one or more types of synthetic compounds such as polyesters, polyfluorides, polycabonates, and the like. It may be a single unit, or consist of two or more fixed units which cannot be separated. For items whose electrodes consist of a metallic film deposited (metallized) on the dielectric material, see CAPACITOR, FIXED, METALLIZED, PAPER-PLASTIC DIELECTRIC. View more Plastic Dielectric Fixed Capacitor

5910-01-257-2956 CAPACITOR,FIXED,PLASTIC DIELECTRIC 5910012572956 012572956

Managed by United States
NSN Created on 16 Jun 1987
Data Last Changed
May 2023
NATO Update Count
9
NATO Data Quality
AAQL Style 26B for 5910-01-257-2956 1/2
NSN 5910-01-257-2956 (Identification) 1/2
AEBZ Style 1C for 5910-01-257-2956 2/2
NSN 5910-01-257-2956 (Identification) 2/2

5910-01-257-2956 Stock and Availability Marketplace 5910-01-257-2956

Need Help?
Request a Quotation from participating marketplace vendors

5910-01-257-2956 Related Documents Related Documents 5910-01-257-2956 5+ Documents (More...)

MIL-PRF-19978/13 CQR29A1ME684G3P CQR29A1ME684G3M MILC19978-13 A capacitor whose capacitance value cannot
(Identification) 1/2 NSN 5910-01-257-2956 (Identification) 2/2 - - 1.
United States (US) 4. 5910-01-257-2956 Marketplace Restrictions Approved Sources Datasheet Management
CQR29A1MB685J3P MILC19978-13 A capacitor whose capacitance value cannot be adjusted or varied, having
A capacitor whose capacitance value cannot be adjusted or varied, having MILC19978-13 CAPACITOR,FIXED
Plastic Dielectric Fixed Capacitor 012572956 CQR29A1ME684G3P CQR29A1ME684G3M MILC19978-13 A capacitor
CQR29A1MG124J3P MILC19978-13 A capacitor whose capacitance value cannot be adjusted or varied, having
CQR29A1MA272J3P MILC19978-13 CQR29A1MA272J3M A capacitor whose capacitance value cannot be adjusted
MILC19978-13 CAPACITOR,FIXED,PLASTIC DIELECTRIC 43 EA NS Request Quotation Subscribe to View Vendor
CQR29A3MC274G3P MILC19978-13 A capacitor whose capacitance value cannot be adjusted or varied, having
A capacitor whose capacitance value cannot be adjusted or varied, having MILC19978-13 CAPACITOR,FIXED
CQR29A1MA272J3M A capacitor whose capacitance value cannot be adjusted MILC19978-13 CAPACITOR,FIXED
your Account Upgrade 5910-01-072-3764Plastic Dielectric Fixed Capacitor5910010723764 010723764 MIL-PRF-19978/13
CQR29A1MA563G3P MILC19978-13 A capacitor whose capacitance value cannot be adjusted or varied, having
MILC19978-13 CAPACITOR,FIXED,PLASTIC DIELECTRIC 43 EA NS Request Quotation Subscribe to View Vendor Details

5910-01-257-2956 Demil Restrictions 5910-01-257-2956

DEMIL: A | DEMILI: | CRITICALITY: X | HMIC: P | PMIC: A | EDC: | ADPEC:

5910-01-257-2956 is a Plastic Dielectric Fixed Capacitor that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. This item does not contain a precious metal.

5910-01-257-2956 HTS and ScheduleB Import and Export 5910-01-257-2956

5910-01-257-2956 End Users End Users 5910-01-257-2956

US Navy (N9BN)
Effective Date:
1 Dec 2013
Supplementary Collaborators:
GG
Greece (ZU01)
Effective Date:
1 Jul 2011

5910-01-257-2956 Manufacturers Approved Sources 5910-01-257-2956

5910-01-257-2956 Technical Data Datasheet 5910-01-257-2956

Characteristic
Specifications
FIIG
A010B0
Body Diameter [ABPM]
0.812 Inches Maximum
Body Length [ADAQ]
2.218 Inches Nominal
Body Style [AAQL]
W/O Mtg Facilities, Axial Terminals
Capacitance Value Per Section [CQBQ]
0.680 Microfarads Single Section
Case Insulation Material [CWSZ]
Plastic
Case Material [CWJK]
Metal
Dielectric Material [CWSS]
Plastic Polyethylene Terephthalate
Dissipation Factor At Reference Temp In Percent [CWPM]
0.6000
Features Provided [CBBL]
Hermetically Sealed Case
Nonderated Continuous Voltage Rating And Type Per Section [CQWM]
400.0 Dc Single Section
Nonderated Operating Temp [CQJJ]
-65.0 Deg Celsius Minimum And 85.0 Deg Celsius Maximum
Insulation Resistance At Maximum Operating Temp [CQBF]
5000.0 Megohm-Microfarads
Insulation Resistance At Reference Temp [CWPK]
100000.0 Megohms
Internal Electrical Connection Type [AFHW]
Extended Foil
Reliability Indicator [AARG]
Established
Reliability Failure Rate Level In Percent [AARH]
0.1000
Schematic Diagram Designator [AEBZ]
No Common Or Grounded Electrode(S)
Tolerance Range Per Section [CRTP]
-2.00/+2.00 Percent Single Section
Specification/Standard Data [ZZZK]
81349-Mil-C-19978/13 Government Specification
Terminal Diameter [AEBT]
0.032 Inches Nominal
Terminal Length [ABJT]
1.625 Inches Minimum
Terminal Surface Treatment [CWSG]
Solder
Terminal Type And Quantity [TTQY]
2 Uninsulated Wire Lead
Test Data Document [TEST]
81349-Mil-C-19978 Specification (Includes Engineering Type Bulletins, Brochures,Etc., That Reflect Specification Type Data In Specification Format; Excludes Commercial Catalogs, Industry Directories, And Similar Trade Publications, Reflecting General Type Data On Certain Environmental And Performance Requirements And Test Conditions That Are Shown As "Typical", "Average", "Nominal", Etc.).

5910-01-257-2956 Stock, Inventory and Procurement DLA Procurement Analysis 5910-01-257-2956

DLA Administrative Lead Time:
Subscribe
DLA Production Lead Time:
Subscribe
Subscribe to View DLA Inventory and Forecast...

5910-01-257-2956 Management Data Management Data 5910-01-257-2956

Effective Date
Organization
Unit of Issue
Unit Price
Qty Unit Pack
Oct 2022
Defense Logistics Agency (DS)
EA
Subscribe
1
Oct 2021
Department of the Navy (DN)
EA
Subscribe
1
Oct 2020
Department of the Navy (DN)
EA
Subscribe
1
Oct 2019
Department of the Navy (DN)
EA
Subscribe
1

Navy Navy

Cognizance:
9B
Navy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg

5910-01-257-2956 Similar Items Similar Supply Items to 5910-01-257-2956

5910-01-257-2956 Freight Data Freight Information 5910-01-257-2956

5910-01-257-2956 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 061400. A Sub NMFC of X. It has a NMFC Description of CONDENSERS/PARTS NOI/CAPACITORS. 5910-01-257-2956 is rated as class 77.5 when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 34450 which rates the freight between FCL and LCL. 5910-01-257-2956 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 72D for ocean manifesting and military sealift. 5910-01-257-2956 is not classified as a special type of cargo when transported by water. 5910-01-257-2956 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.

5910-01-257-2956 Packaging Data Packaging Data 5910-01-257-2956

Responsible Activity
Packaging Data Source
Primary Inventory Control Activity (PICA)
--

Item Pack Level (Unpackaged)

Item Size
Item Weight
Characteristics
Weight/Dimensions Category
Fragility
Item Preservation
--
--
--
0.25 lb or less, one dimension 2" or less, other dimensions less than 24"
85 to 110G
No Requirement

Unit Pack Level (Packaged)

Quantity per Pack
Unit Size
Unit Weight
Unit Cube
Preservation Method
Cleaning/Drying
1
--
--
--
--
--
Preservation Material
Wrapping Material
Cushioning/Dunnage
Cushioning Thickness
Container
Special Marking
--
--
--
--
--
Special requirements

Intermediate Pack Level

Quantity of Unit Packs
Container
See Method of Preservation
--

5910-01-257-2956 Contracting Technical Data File (CTDF) Contracting Technical Data File (CTDF) 5910-01-257-2956 October 2021

Criticality and Quality

Critical Item Code:
Flight Safety:
Life Support:
Certified Samples:
Serialization:
First Article Test (FAT):
Certificate of Quality Compliance:
Production Lot Testing:
Special Testing:
Qualified Products List (QPL):

Commercial Properties

Government Furnished Material:
Government Furnished Tooling:
Government Furnished Property:
Price Evaluation Code:
Diminshing Manufacturing Sources:
Warranty:
Commerical Off The Shelf (COTS):
End Item Application:
Auctioning Candidate:
Source of Procurement:
Contract Option:

Restrictions

Boeing Rights Guard:
Export Controlled:
Controlled Technical Data Package (TDP):
Restricted Technical Data Package (TDP):
Contains Classified Material
Weapons System Indicator Code (WSIC):
N

Packaging Requirements

Packaging Determination Table:
Packaging Review Code:
Special Packaging Instruction Number (SPIN):
Special Packaging Instruction Number Revision:
Special Packaging Instruction Number Date:
Pallet Reference Number Required: