Premium Information is available for this item - Upgrade for $1 a day
5910-01-251-2100
Ceramic Dielectric Fixed Capacitor
5910012512100 012512100 RPE122166C0G1R5B100V RPE122-166C0G1R5B100V 913-2609-020 SR211A1R5CAA
A capacitor, whose capacitance value cannot be adjusted or varied, having a ceramic dielectric.It may be a single unit, or consist of two or more fixed units which cannot be separated. View more Ceramic Dielectric Fixed Capacitor
June 2023
11


Marketplace 5910-01-251-2100
Request a Quotation from participating marketplace vendors
Related Documents 5910-01-251-2100 1+ Documents (More...)
RQST NE Updated Every Day 5910-01-251-2100 RQST Updated Every Day 5910-01-251-2100 RQST NE Related Documents
5910-01-251-2100 1+ Documents ( More... ) https//www.nsnlookup.com /fsg-59/fsc-5910/us 5910-01-251-2100
Restrictions 5910-01-251-2100
5910-01-251-2100 is a Ceramic Dielectric Fixed Capacitor that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. This item does not contain a precious metal.
Import and Export 5910-01-251-2100
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 5910-01-251-2100
- Greece (ZU01)
- Effective Date:
- 1 Jul 2005
Approved Sources 5910-01-251-2100
- Part Number
- Manufacturer
- Status
- RPE122166C0G1R5B100V
- Manufacturer
- 0BCD9 - Murata Erie North America Inc (Obsolete)
- Original Design
- Original Design
- RPE122-166C0G1R5B100V
- 51406 - Murata Erie North America Inc (Active)
- Canceled/Obsolete
- Canceled/Obsolete
- 913-2609-020
- 13499 - Rockwell Collins, Inc. (Active)
- Canceled/Obsolete
- Canceled/Obsolete
- SR211A1R5CAA
- 96095 - Avx Corporation (Obsolete)
- Canceled/Obsolete
- Canceled/Obsolete
- 913-2609-020
- 95105 - Rockwell Collins, Inc. (Active)
- Vendor Drawing
- Vendor Drawing
Datasheet 5910-01-251-2100
- Characteristic
- Specifications
- FIIG
- Specifications
- A010B0
- Body Height [ADAU]
- 0.125 Inches Maximum
- Body Length [ADAQ]
- 0.200 Inches Maximum
- Body Width [ADAT]
- 0.260 Inches Maximum
- Body Style [AAQL]
- W/O Mtg Facilities Terminal(S) On One Surface
- Capacitance Value Per Section [CQBQ]
- 1.500 Picofarads Single Section
- Case Material [CWJK]
- Plastic
- Center To Center Distance Between Terminals Parallel To Length [AEBP]
- 0.200 Inches Nominal
- Dissipation Factor At Reference Temp In Percent [CWPM]
- 0.200
- Nonderated Continuous Voltage Rating And Type Per Section [CQWM]
- 100.0 Dc Single Section
- Nonderated Operating Temp [CQJJ]
- -55.0 Deg Celsius Minimum And 125.0 Deg Celsius Maximum
- Temp Coefficient Of Capacitance Per Section In Ppm Per Deg Celsius [CQLZ]
- 0.0 Single Section
- Insulation Resistance At Reference Temp [CWPK]
- 100000.0 Megohms
- Reliability Indicator [AARG]
- Not Established
- Schematic Diagram Designator [AEBZ]
- No Common Or Grounded Electrode(S)
- Tolerance Of Temp Coefficient Per Section In Ppm Per Deg Celsius [CRHD]
- -30.0/+30.0 Single Section
- Tolerance Range Per Section [CRTP]
- -0.10/+0.10 Picofarads Single Section
- Terminal Diameter [AEBT]
- 0.020 Inches Nominal
- Terminal Length [ABJT]
- 1.125 Inches Minimum
- Terminal Surface Treatment [CWSG]
- Solder
- Terminal Type And Quantity [TTQY]
- 2 Uninsulated Wire Lead
Similar Supply Items to 5910-01-251-2100


















Freight Information 5910-01-251-2100
5910-01-251-2100 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 061400. A Sub NMFC of X. It has a NMFC Description of CONDENSERS/PARTS NOI/CAPACITORS. 5910-01-251-2100 is rated as class 77.5 when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 34450 which rates the freight between FCL and LCL. 5910-01-251-2100 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 72D for ocean manifesting and military sealift. 5910-01-251-2100 is not classified as a special type of cargo when transported by water. 5910-01-251-2100 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.
Packaging Data 5910-01-251-2100
- Responsible Activity
- Packaging Data Source
- Primary Inventory Control Activity (PICA)
- Validated Correction
Item Pack Level (Unpackaged)
- Item Size
- Item Weight
- Characteristics
- Weight/Dimensions Category
- Fragility
- Item Preservation
- Item Weight
- --
- --
- --
- 0.25 lb or less, one dimension 2" or less, other dimensions less than 24"
- 85 to 110G
- No Requirement
- --
Unit Pack Level (Packaged)
- Quantity per Pack
- Unit Size
- Unit Weight
- Unit Cube
- Preservation Method
- Cleaning/Drying
- Unit Size
- --
- --
- --
- --
- --
- --
- --
- Preservation Material
- Wrapping Material
- Cushioning/Dunnage
- Cushioning Thickness
- Container
- Special Marking
- Wrapping Material
- --
- --
- --
- --
- --
- No special marking
- --
Intermediate Pack Level
- Quantity of Unit Packs
- Container
- See Method of Preservation
- --