5910-01-051-9643
Electrolytic Fixed Capacitor
5910010519643 010519643 55-0743-641L2D2 UFLN122 602D698
A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically formed film as the dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated. View more Electrolytic Fixed Capacitor
November 2023
32


Marketplace 5910-01-051-9643
Request a Quotation from participating marketplace vendors
Related Documents 5910-01-051-9643 2+ Documents (More...)
NE Updated Every Day 5910-01-051-9643 RQST Updated Every Day 5910-01-051-9643 RQST NE Related Documents
5910-01-051-9643 2+ Documents ( More... ) https//www.nsnlookup.com /fsg-59/fsc-5910/us 5910-01-051-9643
Electrolytic Fixed Capacitor 5910010519643 Upgrade your Account Upgrade 5910-01-051-9643Electrolytic
Fixed Capacitor5910010519643 010519643 55-0743 602D698 CAPACITOR,FIXED,ELECTROLYTIC 2 EA NS Request
Restrictions 5910-01-051-9643
5910-01-051-9643 is a Electrolytic Fixed Capacitor that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. The precious metals content of this item is unknown.
Import and Export 5910-01-051-9643
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 5910-01-051-9643
- US Coast Guard (C920)
- Effective Date:
- 1 Jul 2014
- US Air Force (FXGX)
- Effective Date:
- 1 Aug 2006
- Former MOE Rule:
- FXTX
- US Navy (N9BN)
- Effective Date:
- 1 Aug 2006
- Former MOE Rule:
- N9ND
- Supplementary Collaborators:
- GTKE
- Austria (WB01)
- Effective Date:
- 1 Feb 2005
- Poland (WP01)
- Effective Date:
- 1 Jul 2011
- Spain (YB01)
- Effective Date:
- 1 Apr 1991
- Singapore (YJ01)
- Effective Date:
- 1 Apr 1991
- Australia (ZA01)
- Effective Date:
- 1 Apr 1991
- New Zealand (ZE01)
- Effective Date:
- 1 Apr 1991
- France (ZF01)
- Effective Date:
- 1 Apr 1996
- Germany (ZG01)
- Effective Date:
- 1 Feb 2005
- Republic of Korea (ZH01)
- Effective Date:
- 1 Aug 1995
- Norway (ZT01)
- Effective Date:
- 1 May 1994
- Greece (ZU01)
- Effective Date:
- 1 Jul 2005
- NATO Maintenance and Supply Agency (ZX01)
- Effective Date:
- 1 Aug 2008
Approved Sources 5910-01-051-9643
- Part Number
- Manufacturer
- Status
- 55-0743-641L2D2
- Manufacturer
- 72914 - Grimes Aerospace Company (Active)
- Primary Buy
- Primary Buy
- UFLN122
- 1CW50 - Mjo Industries, Inc. (Active)
- Incomplete Secondary Reference
- Incomplete Secondary Reference
- UFLN122
- 62643 - United Chemi-Con, Inc. (Active)
- Secondary Buy
- Secondary Buy
- 602D698
- 7M138 - United Chemi-Con Mfg Inc (Active)
- Canceled/Obsolete
- Canceled/Obsolete
- 55-0743-641L2D2
- 56289 - Sprague Electric Co World Hqs (Active)
- Canceled/Obsolete
- Canceled/Obsolete
Datasheet 5910-01-051-9643
- Characteristic
- Specifications
- FIIG
- Specifications
- A010B0
- Electrical Polarization [AECQ]
- Polarized
- Anode Type [AECE]
- Plain Foil
- Body Diameter [ABPM]
- 1.453 Inches Maximum
- Body Length [ADAQ]
- 4.750 Inches Maximum
- Body Style [AAQL]
- W/O Mtg Facilities, Terminal(S) On One End
- Capacitance Value Per Section [CQBQ]
- 640.000 Microfarads Single Section
- Capacitive Electrode Material [CWNJ]
- Aluminum
- Case Insulation Material [CWSZ]
- Plastic
- Case Material [CWJK]
- Metal
- Center To Center Distance Between Terminals Parallel To Diameter [AEBS]
- 0.500 Inches Nominal
- Nonderated Continuous Voltage Rating And Type Per Section [CQWM]
- 250.0 Dc Single Section
- Nonderated Operating Temp [CQJJ]
- -55.0 Deg Celsius Minimum And 85.0 Deg Celsius Maximum
- Reliability Indicator [AARG]
- Not Established
- Schematic Diagram Designator [AEBZ]
- No Common Or Grounded Electrode(S)
- Tolerance Range Per Section [CRTP]
- -10.00/+30.00 Percent Single Section
- Terminal Diameter [AEBT]
- 0.190 Inches Nominal
- Terminal Length [ABJT]
- 0.250 Inches Nominal
- Terminal Type And Quantity [TTQY]
- 2 Threaded Hole
Weapon Systems (WSDC) 5910-01-051-9643
DLA Procurement Analysis 5910-01-051-9643
- Last Stock Position:
- 48 In Stock
- DLA Administrative Lead Time:
- Subscribe
- DLA Production Lead Time:
- Subscribe
Management Data 5910-01-051-9643
Army
- Materiel Category and Inventory Manager:
- Q
- Electronics Materiel (DLA/GSA Items)
- Appropriation and Budget Activity:
- 2
- Stock Fund Secondary Items
- Management Inventory Segment:
- 2
- Non-Repairable Items(Exclusive of Insurance and Provisioning Items)
This code will be used to identify items, which are not reparable.
- Weapons System / End Item / Homogeneous Group:
- 00
- DLA/GSA Material
DLA/GSA-Managed Items that cannot be identified to a specific Army Weapons Systems/End Item
- Accounting Requirements:
- X
- Expendable item.An item of Army property coded with an ARC of X in the AMDF. Expendable items require no formal accountability after issue from a stock record account.Commercial and fabricated items similar to items coded X in the AMDF are considered expendable items.
Air Force
- Fund:
- SF
- Stock fund applicable to items managed for the Air Force by the respective Inventory Control Point
- Budget:
- 9
- 57X4921.070 - General Support DIV - Air Force decentralized managed expense items (ERRC XB3, XF3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors
- Aggregation Code:
- EH
- ELECTRONIC COMPONENTS
- Price Validation Code:
- N
- The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
The price has not been analyzed or reviewed for accuracy.
ZOP or Standard price challenges are permissible but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of āLā or āFā, then it must be evaluated locally where purchased or fabricated.
- Expendability
Recoverability
Repairability: - N
- Expendable. Condemn at User. Stock Fund (except Munitions).
Navy
- Cognizance:
- 9B
- Navy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Similar Supply Items to 5910-01-051-9643


















Freight Information 5910-01-051-9643
5910-01-051-9643 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 061400. A Sub NMFC of X. It has a NMFC Description of CONDENSERS/PARTS NOI/CAPACITORS. 5910-01-051-9643 is rated as class 77.5 when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 34450 which rates the freight between FCL and LCL. 5910-01-051-9643 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 72D for ocean manifesting and military sealift. 5910-01-051-9643 is not classified as a special type of cargo when transported by water. 5910-01-051-9643 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.
Packaging Data 5910-01-051-9643
- Responsible Activity
- Packaging Data Source
- Primary Inventory Control Activity (PICA)
- --
Item Pack Level (Unpackaged)
- Item Size
- Item Weight
- Characteristics
- Weight/Dimensions Category
- Fragility
- Item Preservation
- Item Weight
- --
- --
- --
- Over 10lb
- Less than 85G
- No Requirement
- --
Unit Pack Level (Packaged)
- Quantity per Pack
- Unit Size
- Unit Weight
- Unit Cube
- Preservation Method
- Cleaning/Drying
- Unit Size
- 1
- 7.0" H x 3.0" W x 3.0" L
- --
- --
- --
- Any Suitable Process
- 7.0" H x 3.0" W x 3.0" L
- Preservation Material
- Wrapping Material
- Cushioning/Dunnage
- Cushioning Thickness
- Container
- Special Marking
- Wrapping Material
- No Requirement
- No Requirement
- PPP-C-795, Cellular Plastic Film Cushioning; or A-A-3129, Open Cell Plastic Cushioning; or PPP-C-1797, Polypropylene Foam Cushioning; or A-A-59136, Polyethylene Foam Cushioning
- --
- PPP-B-566, PPP-B-676, or ASTM-D5118, Folding, Setup or Fiberboard Box
- Special requirements
- No Requirement
Intermediate Pack Level
- Quantity of Unit Packs
- Container
- Any Suitable Fiber Box
Procurement History 5910-01-051-9643 20 Records
- Contract
- Date
- CAGE
- Quantity
- Net Price
- Std Price
- CAGE
- SPE7M524V0611
- 01 Nov 2023
- Subscribe
- 46
- Subscribe
- Subscribe
- Subscribe
- SPE7M524V0448
- 23 Oct 2023
- Subscribe
- 250
- Subscribe
- Subscribe
- Subscribe
- SPE7M524V0137
- 10 Oct 2023
- Subscribe
- 300
- Subscribe
- Subscribe
- Subscribe
- SPE7MC23V7676
- 08 Aug 2023
- Subscribe
- 43
- Subscribe
- Subscribe
- Subscribe
- SPE7MC23V7086
- 19 Jul 2023
- Subscribe
- 272
- Subscribe
- Subscribe
- Subscribe
- SPE7M523P4815
- 25 May 2023
- Subscribe
- 50
- Subscribe
- Subscribe
- Subscribe
- SPE7M523P4814
- 25 May 2023
- Subscribe
- 286
- Subscribe
- Subscribe
- Subscribe
- SPE7M523P4189
- 27 Apr 2023
- Subscribe
- 108
- Subscribe
- Subscribe
- Subscribe
- SPE7M122F456J
- 24 May 2022
- Subscribe
- 79
- Subscribe
- Subscribe
- Subscribe
- SPE7M122F456J
- 24 May 2022
- Subscribe
- 79
- Subscribe
- Subscribe
- Subscribe
- SPE7M122F184F
- 18 Feb 2022
- Subscribe
- 122
- Subscribe
- Subscribe
- Subscribe
- SPE7M122F184F
- 18 Feb 2022
- Subscribe
- 122
- Subscribe
- Subscribe
- Subscribe
- SPE7M122F4802
- 19 Oct 2021
- Subscribe
- 66
- Subscribe
- Subscribe
- Subscribe
- SPE7M122F4802
- 19 Oct 2021
- Subscribe
- 66
- Subscribe
- Subscribe
- Subscribe
- SPE7M121F562M
- 23 Sep 2021
- Subscribe
- 78
- Subscribe
- Subscribe
- Subscribe
- SPE7M121F562M
- 23 Sep 2021
- Subscribe
- 78
- Subscribe
- Subscribe
- Subscribe
- SPE7M519V0800
- 17 Oct 2018
- Subscribe
- 57
- Subscribe
- Subscribe
- Subscribe
- SPE7M518V9562
- 06 Jun 2018
- Subscribe
- 89
- Subscribe
- Subscribe
- Subscribe
- SPE7M518V6690
- 29 Mar 2018
- Subscribe
- 95
- Subscribe
- Subscribe
- Subscribe
- SPE4A617V9838
- 22 Mar 2017
- Subscribe
- 77
- Subscribe
- Subscribe
- Subscribe
Contracting Technical Data File (CTDF) 5910-01-051-9643 October 2021
Criticality and Quality
- Critical Item Code:
- X
- Flight Safety:
- Life Support:
- Certified Samples:
- Serialization:
- First Article Test (FAT):
- Certificate of Quality Compliance:
- Production Lot Testing:
- Special Testing:
- Qualified Products List (QPL):
Commercial Properties
- Government Furnished Material:
- Government Furnished Tooling:
- Government Furnished Property:
- Price Evaluation Code:
- Diminshing Manufacturing Sources:
- Warranty:
- Commerical Off The Shelf (COTS):
- End Item Application:
- Auctioning Candidate:
- Source of Procurement:
- Contract Option:
Restrictions
- Boeing Rights Guard:
- Export Controlled:
- Controlled Technical Data Package (TDP):
- Restricted Technical Data Package (TDP):
- Contains Classified Material
- Weapons System Indicator Code (WSIC):
- F
Packaging Requirements
- Packaging Determination Table:
- Packaging Review Code:
- N
- Special Packaging Instruction Number (SPIN):
- Special Packaging Instruction Number Revision:
- Special Packaging Instruction Number Date:
- Pallet Reference Number Required: