Premium Information is available for this item - Upgrade for $1 a day
5910-00-800-2818
Electrolytic Fixed Capacitor
5910008002818 008002818 MILC62 CE52C550M
A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically formed film as the dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated. View more Electrolytic Fixed Capacitor
![]()
May 2023
5


 Marketplace  5910-00-800-2818
Request a Quotation from participating marketplace vendors
 Related Documents  5910-00-800-2818  5+ Documents (More...) 
RQST NE Updated Every Day 5910-00-800-2818 RQST Updated Every Day 5910-00-800-2818 RQST NE Related Documents
5910-00-800-2818 5+ Documents ( More... ) https//www.nsnlookup.com /fsg-59/fsc-5910/us 5910-00-800-2818
/fsg-53/fsc-5331/us
Electrolytic Fixed Capacitor 5910008002818 5910-00-800-2818 5+ Documents ( More... ) https//www.nsnlookup.com
/fsg-59/fsc-5910/us 5910-00-800-2818 RQST Updated Every Day 5910-00-800-2818 RQST NE Related Documents
Electrolytic Fixed Capacitor 5910008002818 Restrictions Approved Sources Datasheet Management https
-10 MILC62 CE53C600J A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically
www.nsnlookup.com /fsg-59/fsc-5910/us 5910-00-989-2191 Electrolytic Fixed Capacitor 5910009892191 MILC62
Upgrade your Account Upgrade 5910-00-952-9009Electrolytic Fixed Capacitor5910009529009 009529009 MILC62
MILC62-10 009707169 MILC62 Upgrade your Account Upgrade 5910-00-089-5380Electrolytic Fixed Capacitor5910000895380
 Restrictions  5910-00-800-2818
5910-00-800-2818 is a Electrolytic Fixed Capacitor that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. The precious metals content of this item is unknown.
 Import and Export  5910-00-800-2818
- Schedule B
 - Subscribe to View Schedule B
 - HTS Code
 - Subscribe to View HTS Code
 
 End Users  5910-00-800-2818
- Republic of Korea (ZH01)   
- Effective Date:
  - 1 Apr 1991
 
 Approved Sources  5910-00-800-2818
- Part Number
- Manufacturer
 - Status
 - CE52C550M
  - Manufacturer
 -  81349 - Military Specifications (Active) 
- Definitive Standard
  - Definitive Standard
 - MILC62
 -  81349 - Military Specifications (Active) 
- Incomplete Standard
  - Incomplete Standard
 
 Datasheet  5910-00-800-2818
- Characteristic
- Specifications
 - FIIG
  - Specifications
 - A010B0
 - Electrical Polarization [AECQ]
 - Polarized
 - Anode Type [AECE]
 - Plain Foil
 - Body Diameter [ABPM]
 - 1.500 Inches Nominal
 - Body Length [ADAQ]
 - 3.000 Inches Nominal
 - Body Style [AAQL]
 - W/O Mtg Facilities, Terminal(S) On One End
 - Capacitance Value Per Section [CQBQ]
 - 55.000 Microfarads All Sections
 - Capacitive Electrode Material [CWNJ]
 - Aluminum
 - Case Material [CWJK]
 - Metal
 - Dissipation Factor At Reference Temp In Percent [CWPM]
 - 12.0000
 - Nonderated Continuous Voltage Rating And Type Per Section [CQWM]
 - 250.0 Dc All Sections
 - Nonderated Operating Temp [CQJJ]
 - -40.0 Deg Celsius Minimum And 85.0 Deg Celsius Maximum
 - Reliability Indicator [AARG]
 - Not Established
 - Schematic Diagram Designator [AEBZ]
 - One Terminal Common To Each Section
 - Section Quantity [BWGP]
 - 2
 - Tolerance Range Per Section [CRTP]
 - -10.00/+50.00 Percent 1St Section
 - Tolerance Range Per Section [CRTP]
 - -10.00/+50.00 Percent 2Nd Section
 - Terminal Surface Treatment [CWSG]
 - Nickel
 - Terminal Type And Quantity [TTQY]
 - 3 Standard Tube Base
 
 Similar Supply Items to 5910-00-800-2818


















 Freight Information  5910-00-800-2818
5910-00-800-2818 has freight characteristics.. 5910-00-800-2818 has a variance between NMFC and UFC when transported by rail and the description should be consulted.