Premium Information is available for this item - Upgrade for $1 a day

5910-00-450-8592

Ceramic Dielectric Fixed Capacitor

5910004508592 004508592 8131+100651104Z 107039 3430-100E104 499-021-109 VK28ZU104 1400158-15 8131-100651104M 8131-100-651-104M 8131M100-651-104M 5030ES100RD104M 1591012131N 8131M100651 104M A5213 3041655 820-028-001 3420-100E104M

A capacitor, whose capacitance value cannot be adjusted or varied, having a ceramic dielectric.It may be a single unit, or consist of two or more fixed units which cannot be separated. View more Ceramic Dielectric Fixed Capacitor

5910-00-450-8592 CAPACITOR,FIXED,CERAMIC DIELECTRIC 5910004508592 004508592

Managed by United States
NSN Created on 26 Dec 1969
Data Last Changed
November 2023
NATO Update Count
55
NATO Data Quality
AAQL Style 27A for 5910-00-450-8592 1/2
NSN 5910-00-450-8592 (Identification) 1/2
AEBZ Style 1C for 5910-00-450-8592 2/2
NSN 5910-00-450-8592 (Identification) 2/2

5910-00-450-8592 Stock and Availability Marketplace 5910-00-450-8592

5910-00-450-8592 Related Documents Related Documents 5910-00-450-8592 5+ Documents (More...)

8131+100651104Z 107039 3430-100E104 499-021-109 VK28ZU104 1400158-15 8131-100651104M 8131-100-651-104M
8131M100-651-104M 5030ES100RD104M 1591012131N 8131M100651 104M A5213 3041655 820-028-001 3420-100E104M
-00-450-8592 RQST NE Updated Every Day 5910-00-450-8592 RQST Updated Every Day 5910-00-450-8592 RQST
JavaScript in your web browser . 4330-21-900-4933Fluid Filter Element4330219004933 219004933 PC50F 3041655
Ceramic Dielectric https//www.nsnlookup.com /fsg-59/fsc-5910/us 5910-00-450-8592 Ceramic Dielectric
Fixed Capacitor 004508592 100651104M 8131-100-651-104M 8131M100-651-104M 5030ES100RD104M 1591012131N
Ceramic Dielectric Fixed Capacitor 004508592 004508592 8131+100651104Z 107039 3430-100E104 499-
021-109 VK28ZU104 1400158-15 8131-100651104M 8131-100-651-104M Vendor Details... 8131100651104M CAPACITOR
,FIXED,CERAMIC DIELECTRIC 87 EA NS Request Quotation 8131-100-651-104M 8131-100-651-104M8131M100-651-
how to enable JavaScript in your web browser . 4730-15-174-6512Tube Elbow4730151746512 151746512 A-107039
-1017 179004170 (241)A4578A-107039-1017 A fitting that forms an angle of less than 180 degrees (3.141
-1017179004170 (241)A4578A-107039-1017 A fitting that forms an angle of less than 180 degrees RQST NE
how to enable JavaScript in your web browser . 4730-15-117-9644Tube Elbow4730151179644 151179644 A-107039
-1013 179004145 179004167 (241)A4578A-107039-1013 A fitting that forms an angle of less than 180 degrees
-1013179004145179004167 (241)A4578A-107039-1013 A fitting that https//www.nsnlookup.com /fsg-59/fsc-

5910-00-450-8592 Demil Restrictions 5910-00-450-8592

DEMIL: A | DEMILI: | CRITICALITY: X | HMIC: P | PMIC: A | EDC: | ADPEC:

5910-00-450-8592 is a Ceramic Dielectric Fixed Capacitor that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. This item does not contain a precious metal.

5910-00-450-8592 HTS and ScheduleB Import and Export 5910-00-450-8592

5910-00-450-8592 End Users End Users 5910-00-450-8592

Bulgaria (WU01)
Effective Date:
1 Oct 2002
Brazil (YA01)
Effective Date:
1 Jan 2002
Spain (YB01)
Effective Date:
1 Apr 1991
Kuwait (YK01)
Effective Date:
1 Jan 2015
Saudi Arabia (YS01)
Effective Date:
1 Feb 2015
Australia (ZA01)
Effective Date:
1 Apr 1991
Republic of Korea (ZH01)
Effective Date:
1 Apr 1991
Italy (ZR01)
Effective Date:
1 Jul 1997
Norway (ZT01)
Effective Date:
1 Apr 1991

5910-00-450-8592 Manufacturers Approved Sources 5910-00-450-8592

Part Number
Manufacturer
Status
3430-100E104
04222 - Kyocera Avx Components Corporation (Active)
Primary Buy
499-021-109
07421 - L3harris Interstate Electronics (Active)
Secondary Buy
VK28ZU104
95275 - Vitramon Inc Po Box 544 Bridgeport (Active)
Secondary Buy
1400158-15
1PQF4 - Cae Usa Inc. (Active)
Secondary Buy
8131-100651104M
72982 - Erie Specialty Products Inc (Active)
Canceled/Obsolete
8131-100-651-104M
72982 - Erie Specialty Products Inc (Active)
Canceled/Obsolete
8131M100-651-104M
72982 - Erie Specialty Products Inc (Active)
Canceled/Obsolete
5030ES100RD104M
20932 - Illinois Tool Works Inc Emcon Div (Obsolete)
Canceled/Obsolete
1591012131N
A2312 - Sma Segnalamento Marittimo Aereo (Obsolete)
Canceled/Obsolete
1400158-15
36378 - Raytheon Technical Services Company (Replaced)
Canceled/Obsolete
8131M100651 104M
18796 - Murata Erie North America Inc State (Obsolete)
Canceled/Obsolete
A5213
81535 - Aeronautical Communications (Obsolete)
Canceled/Obsolete
3041655
21340 - Itt Telecom Products Corp (Obsolete)
Canceled/Obsolete
820-028-001
17903 - Andrew Scicomm Inc (Obsolete)
Canceled/Obsolete
8131-100651104M
18796 - Murata Erie North America Inc State (Obsolete)
Canceled/Obsolete
3420-100E104M
00656 - Aerovox Corp. (Obsolete)
Canceled/Obsolete
8131+100651104Z
72982 - Erie Specialty Products Inc (Active)
Advisory Reference
107039
01220 - Systron-Donner Corp (Obsolete)
Advisory Reference

5910-00-450-8592 Technical Data Datasheet 5910-00-450-8592

Characteristic
Specifications
FIIG
A010B0
Body Height [ADAU]
0.150 Inches Maximum
Body Length [ADAQ]
0.300 Inches Maximum
Body Width [ADAT]
0.300 Inches Maximum
Body Style [AAQL]
W/O Mtg Facilities Terminal(S) On One Surface
Capacitance Value Per Section [CQBQ]
0.100 Microfarads Single Section
Case Material [CWJK]
Plastic
Center To Center Distance Between Terminals Parallel To Length [AEBP]
0.169 Inches Minimum And 0.231 Inches Maximum
Dissipation Factor At Reference Temp In Percent [CWPM]
2.5000
Nonderated Operating Temp [CQJJ]
-55.0 Deg Celsius Minimum And 85.0 Deg Celsius Maximum
Nonderated Continuous Voltage Rating And Type Per Section [CQWM]
100.0 Dc Single Section
Insulation Resistance At Reference Temp [CWPK]
2500.0 Megohm-Microfarads
Reliability Indicator [AARG]
Not Established
Schematic Diagram Designator [AEBZ]
No Common Or Grounded Electrode(S)
Terminal Length [ABJT]
1.500 Inches Minimum
Terminal Type And Quantity [TTQY]
2 Uninsulated Wire Lead
Terminal Surface Treatment [CWSG]
Solder
Tolerance Range Per Section [CRTP]
-20.00/+20.00 Percent Single Section

5910-00-450-8592 Similar Items Similar Supply Items to 5910-00-450-8592

5910-00-450-8592 Freight Data Freight Information 5910-00-450-8592

5910-00-450-8592 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 061400. A Sub NMFC of X. It has a NMFC Description of CONDENSERS/PARTS NOI/CAPACITORS. 5910-00-450-8592 is rated as class 77.5 when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 34450 which rates the freight between FCL and LCL. 5910-00-450-8592 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 658 for ocean manifesting and military sealift. 5910-00-450-8592 is not classified as a special type of cargo when transported by water. 5910-00-450-8592 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.

5910-00-450-8592 Packaging Data Packaging Data 5910-00-450-8592

Responsible Activity
Packaging Data Source
Primary Inventory Control Activity (PICA)
--
Storage Environment
Heated General Purpose – Heated 40 F and above

Item Pack Level (Unpackaged)

Item Size
Item Weight
Characteristics
Weight/Dimensions Category
Fragility
Item Preservation
--
--
--
--
--

Unit Pack Level (Packaged)

Quantity per Pack
Unit Size
Unit Weight
Unit Cube
Preservation Method
Cleaning/Drying
--
--
--
--
--
Special Requirements
Preservation Material
Wrapping Material
Cushioning/Dunnage
Cushioning Thickness
Container
Special Marking
Special Requirement
Special Requirements – see Specific Instructions or Drawings provided
Special Requirements. See Specific Instructions or Drawings Provided
Special Requirements. See Specific Instructions or Drawings Provided
Special requirement – See specific instructions or drawings provided
--

Intermediate Pack Level

Quantity of Unit Packs
Container
Special requirement – See specific instructions or drawings provided