Premium Information is available for this item - Upgrade for $1 a day
5905-01-484-5162
Noninductive Wire Wound Fixed Resistor
5905014845162 014845162 MIL-PRF-39007/10 RWR84N53R6FR MIL-R-39007
A resistor whose ohmic value cannot be adjusted or varied. The resistance element consists of high resistance wire (or ribbon) either wound on an insulated form or constructed so as to be self-supporting. The items must have inherent characteristics of inducing little or no self-inductance. Opposition to current flowo s an inherent property of the resistance wire and is manifested by the heat dissipation in the resistor. Excludes SUPPRESSOR, IGNITION INTERFERENCE. See also RESISTOR (1), FIXENTEWIRE WOUND, INDUCTIVE. View more Noninductive Wire Wound Fixed Resistor
May 2023
6

Marketplace 5905-01-484-5162
Request a Quotation from participating marketplace vendors
Related Documents 5905-01-484-5162 5+ Documents (More...)

/fsg-59/fsc-5905/us
RQST NE Updated Every Day 5905-01-484-5162 RQST Updated Every Day 5905-01-484-5162 RQST NE Related
Documents 5905-01-484-5162 5+ Documents ( More... ) https//www.nsnlookup.com /fsg-59/fsc-5905/us 5905
RWR84S2211FM RWR84S2211FP RWR84S2211FS 4631 995-5B222H 95J2K2 RWR84S2211FR 995-5B222J MIL-R-39007/10
RWR84S4530FS MIL-R-39007/10 Inductive Wire Wound Fixed Resistor 995-5B222J MIL-R-39007/10 https// https
MIL-PRF-39007/10 MIL-R-39007 RWR84S2211FM RWR84S2211FP RWR84S2211FS 4631 995-5B222H 95J2K2 RWR84S2211FR
Wound Fixed Resistor RWR84S2R49FM MIL-R-39007/10 A resistor whose ohmic value cannot be adjusted or
RWR84S2211FM RWR84S2211FP RWR84S2211FS 4631 995-5B222H 95J2K2 RWR84S2211FR 995-5B222J MIL-R-39007/10
RWR84S2211FM RWR84S2211FP RWR84S2211FS 4631 995-5B222H 95J2K2 RWR84S2211FR 995-5B222J MIL-R-39007/10
Noninductive Wire Wound Fixed Resistor RWR84N53R6FR MIL-R-39007 A resistor whose ohmic value cannot
RWR84S2211FM RWR84S2211FP RWR84S2211FS 4631 995-5B222H 95J2K2 RWR84S2211FR 995-5B222J MIL-R-39007/10
Restrictions 5905-01-484-5162
5905-01-484-5162 is a Noninductive Wire Wound Fixed Resistor that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. This item does not contain a precious metal.
Import and Export 5905-01-484-5162
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 5905-01-484-5162
- Germany (ZG01)
- Effective Date:
- 1 Apr 2001
Approved Sources 5905-01-484-5162
- Part Number
- Manufacturer
- Status
- RWR84N53R6FR
- Manufacturer
- 81349 - Military Specifications (Active)
- Definitive Standard
- Definitive Standard
- MIL-PRF-39007/10
- 81349 - Military Specifications (Active)
- Incomplete Standard
- Incomplete Standard
- MIL-R-39007
- 81349 - Military Specifications (Active)
- Canceled/Obsolete
- Canceled/Obsolete
Datasheet 5905-01-484-5162
- Characteristic
- Specifications
- FIIG
- Specifications
- A001A0
- Electrical Resistance [AAPP]
- 53.600 Ohms
- Ambient Temp In Deg Celsius At Full Rated Power [AAQF]
- 25.0
- Ambient Temp In Deg Celsius At Zero Percent Rated Power [AAQG]
- 275.0
- Body Diameter [ABPM]
- 0.281 Inches Minimum And 0.343 Inches Maximum
- Body Length [ADAQ]
- 0.813 Inches Minimum And 0.937 Inches Maximum
- Inclosure Method [AAQZ]
- Encapsulated
- Power Dissipation Rating In Watts [AEFB]
- 7.000 Free Air
- Reliability Failure Rate Level In Percent [AARH]
- 0.001
- Reliability Indicator [AARG]
- Established
- Resistance Tolerance In Percent [AAPQ]
- -0.001/+0.001
- Style Designator [STYL]
- Axial Terminal Each End
- Terminal Type [AARB]
- Wire Lead
Similar Supply Items to 5905-01-484-5162


















Freight Information 5905-01-484-5162
5905-01-484-5162 has freight characteristics.. 5905-01-484-5162 has a variance between NMFC and UFC when transported by rail and the description should be consulted.