5905-01-444-0889
Nonprecision Wire Wound Variable Resistor
5905014440889 014440889 RTDC-24011 36100 33-11-40
A resistor in which a sliding or rolling contact moves over an exposed area of the resistive element to change the ohmic value of the output. The functional tolerance (linearity), if given, of the output is greater than plus of minus 1 percent on linear outputs. Specified outputs such as sine, cosine, tangent, etc., shall be considered to be precision. For items having manually positioned taps designed to be set and fixed prior to use, see RESISTOR, ADJUSTABLE. For items with step by step variation, see RHEOSTAT and RESISTOR, STEP BY STEP. For tandem-mounted items designed to function together as an attenuator (and rated accordingly), see ATTENUATOR, VARIABLE. Excludes RESISTOR (1), VARIABLE, NONWIRE WOUND, NONPRECISION; RESISTOR (1), VARIABLE, NONWIRE WOUND, PRECISION; and RESISTOR (1), VARIABLE, WIRE WOUND, PRECISION. View more Nonprecision Wire Wound Variable Resistor
January 2023
5

Marketplace 5905-01-444-0889
Request a Quotation from participating marketplace vendors
Related Documents 5905-01-444-0889 5+ Documents (More...)
5905-01-444-0889 Nonprecision Wire Wound Variable Resistor Fixed Mounting Mechanical Tachometer,36100
Test Supply 36100 Stabila 36100 Request Global Test Supply 36100 Stabila 36100 NE /fr 6680-14-325- 3506
-G9501 -36100-G970036100-G9700 Managed by Spain NSN Created on 20 Jul 1995 Data Last Changed RQST NE
-G9501 -36100-G970036100-G9700 Managed by Spain https//www.nsnlookup.com /fsg-66/fsc-6680/fr 6680-14
Global Test Supply 36100 Stabila 36100 NE /fr 6680-14-325- 3506 Changed January 36100 Stabila 36100 NE
... 36100 BASE Stabila 36100 635-36165/600-36100 https//www.nsnlookup.com /fsg-74/fsc-7490/us 7490-00
https ... 36100 BASE Stabila https//www.nsnlookup.com /fsg-59/fsc-5905/us 5905-01-444-0889 Nonprecision
36100 ... 36100 BASE Stabila 36100 635-36165/600-36100 Power Transfer Switching Unit 6110014818708 36100
BASE Stabila 36100 635-36165/600-36100 An item that is electrically operated to transfer https .. 36100
BASE Stabila 36100 635-36165/600-36100 NE / https ... 36100 BASE 635-36165/600 -36100 NE / https ...
Restrictions 5905-01-444-0889
5905-01-444-0889 is a Nonprecision Wire Wound Variable Resistor that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. This item does not contain a precious metal.
Import and Export 5905-01-444-0889
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 5905-01-444-0889
- Netherlands (ZN01)
- Effective Date:
- 1 Feb 2002
Approved Sources 5905-01-444-0889
- Part Number
- Manufacturer
- Status
- RTDC-24011
- Manufacturer
- 1EG24 - Russtech Engineering Co., Inc (Active)
- Primary Buy
- Primary Buy
- 36100
- 16290 - Signet Scientific Co (Active)
- Primary Buy
- Primary Buy
- 33-11-40
- 88277 - The Boeing Company (Active)
- Secondary Buy
- Secondary Buy
Datasheet 5905-01-444-0889
- Characteristic
- Specifications
- FIIG
- Specifications
- A002A0
- Special Features [FEAT]
- Rheostat-Dimmer Control
- End Item Identification [AGAV]
- Mcdonnell Douglas Kdc-10
NATO Stock Numbers Related to 5905-01-444-0889
Freight Information 5905-01-444-0889