Premium Information is available for this item - Upgrade for $1 a day
5905-01-432-6525
Composition Fixed Resistor
5905014326525 014326525 MIL-R-39008/2 RCR20G321KS MIL-R-39008/1F
A resistor whose ohmic value cannot be adjusted or varied. The resistance element consists of a mixture of carbon, an insulating material, and suitable binders, either molded together or applied as a thin layer of conducting material on an insulated form. The opposition to the flow of current is an inherent property of the materials used and is manifest by the heat dissipation in the item itself. See also ATTENUATOR, FIXED; RESISTOR, FIXED, FILM; and RESISTOR, THERMAL. Excludes SUPPRESSOR, IGNITION INTERFERENCE. View more Composition Fixed Resistor
![]()
January 2023
4

Marketplace 5905-01-432-6525
Request a Quotation from participating marketplace vendors
Related Documents 5905-01-432-6525 5+ Documents (More...)
MIL-R-39008/2 RESISTOR,FIXED,COMPOSITION 10 EA NS Request Quotation Updated Every Day 5905-01-432-6525
MIL-R-39008/2 RESISTOR,FIXED,COMPOSITION 10 EA NS Request Quotation Updated Every Day 5905-01-432-6525
Composition Fixed Resistor 5905014326525 /2 RCR20G321KS MIL-R-39008/1F A resistor whose ohmic value
MIL-R-39008/2 RESISTOR,FIXED,COMPOSITION 10 EA NS Request Quotation Updated Every Day 5905-01-432-6525
Composition Fixed Resistor 5905014326525 Upgrade your Account Upgrade 5905-01-432-6525Composition
Fixed Resistor5905014326525 014326525 MIL-R-39008 /2 RCR20G321KS MIL-R-39008/1F A resistor whose ohmic
RESISTOR,FIXED,COMPOSITION 10 EA NS Request Quotation Subscribe to View Vendor Details MIL-R-39008/2
RESISTOR,FIXED,COMPOSITION 10 EA NS Request Quotation Subscribe to View Vendor Details MIL-R-39008/2
RESISTOR,FIXED,COMPOSITION 10 EA NS Request Quotation Subscribe to View Vendor Details MIL-R-39008/2
RESISTOR,FIXED,COMPOSITION 10 EA NS Request Quotation Subscribe to View Vendor Details MIL-R-39008/2
Restrictions 5905-01-432-6525
5905-01-432-6525 is a Composition Fixed Resistor that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. This item does not contain a precious metal.
Import and Export 5905-01-432-6525
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 5905-01-432-6525
- United Kingdom (ZK01)
- Effective Date:
- 1 Jun 1996
Approved Sources 5905-01-432-6525
- Part Number
- Manufacturer
- Status
- RCR20G321KS
- Manufacturer
- 81349 - Military Specifications (Active)
- Definitive Standard
- Definitive Standard
- MIL-R-39008/2
- 81349 - Military Specifications (Active)
- Incomplete Standard
- Incomplete Standard
- MIL-R-39008/1F
- 81349 - Military Specifications (Active)
- Canceled/Obsolete
- Canceled/Obsolete
Datasheet 5905-01-432-6525
- Characteristic
- Specifications
- FIIG
- Specifications
- A001A0
- Electrical Resistance [AAPP]
- 32.000 Ohms
- Ambient Temp In Deg Celsius At Full Rated Power [AAQF]
- 70.0
- Ambient Temp In Deg Celsius At Zero Percent Rated Power [AAQG]
- 130.0
- Body Diameter [ABPM]
- 0.138 Inches Nominal
- Body Length [ADAQ]
- 0.375 Inches Nominal
- Inclosure Method [AAQZ]
- Encapsulated
- Power Dissipation Rating In Watts [AEFB]
- 0.500 Free Air
- Reliability Failure Rate Level In Percent [AARH]
- 0.001
- Reliability Indicator [AARG]
- Established
- Resistance Tolerance In Percent [AAPQ]
- -10.000/+10.000
- Specification/Standard Data [ZZZK]
- 81349-Mil-R-39008/1F Government Specification
- Style Designator [STYL]
- Axial Terminal Each End
- Terminal Type [AARB]
- Wire Lead
Similar Supply Items to 5905-01-432-6525


















Freight Information 5905-01-432-6525
5905-01-432-6525 has freight characteristics.. 5905-01-432-6525 has a variance between NMFC and UFC when transported by rail and the description should be consulted.