5905-01-381-8876
Inductive Wire Wound Fixed Resistor
5905013818876 013818876 MIL-R-26/5 RW70UR300F
A resistor whose ohmic value cannot be adjusted or varied. The resistance element consists of high resistance wire (or ribbon) either wound on an insulated form or constructed so as to be self-supporting. The item must have inherent characteristics of inducing self-inductance. Opposition to current flow is an inherent property of the resistance wire and is manifested by the heat dissipation in the resistor. Exclut s SUPPRESSOR, IGNITION INTERFERENCE. See also RESISTOR (1), FIXED, WIRE WOUND, NONINDUCTIVE. View more Inductive Wire Wound Fixed Resistor
November 2023
6

Marketplace 5905-01-381-8876
Request a Quotation from participating marketplace vendors
Related Documents 5905-01-381-8876 5+ Documents (More...)
RQST NE Updated Every Day 5905-01-381-8876 RQST Updated Every Day 5905-01-381-8876 RQST NE Related
Documents 5905-01-381-8876 5+ Documents ( More... ) https//www.nsnlookup.com /fsg-59/fsc-5905/us 5905
A resistor whose ohmic value cannot be adjusted or varied A resistor whose RW74U2942F MIL-R-26/5
Upgrade 5905-01-381-8876Inductive Wire Wound Fixed Resistor5905013818876 013818876 MIL-R-26/5 MIL-R-
MIL-R-26/5 A resistor whose ohmic value cannot be adjusted or varied A resistor whose RW74U2942F
Upgrade 5905-01-381-8876Inductive Wire Wound Fixed Resistor5905013818876 013818876 MIL-R-26/5 A resistor
MIL-R-26/5 A resistor whose ohmic value cannot be adjusted or varied A resistor whose RW74U2942F
value cannot be adjusted or varied A resistor whose RW74U2942F MIL-R-26/5 https//www.nsnlookup.com
A resistor whose ohmic value cannot be adjusted or varied A resistor whose RW74U2942F MIL-R-26/5
MIL-R-26/5 A resistor whose ohmic value cannot be adjusted or varied A resistor whose RW74U2942F
Restrictions 5905-01-381-8876
5905-01-381-8876 is a Inductive Wire Wound Fixed Resistor that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. This item does not contain a precious metal.
End Users 5905-01-381-8876
- Belgium (ZB01)
- Effective Date:
- 1 Oct 1993
Approved Sources 5905-01-381-8876
- Part Number
- Manufacturer
- Status
- RW70UR300F
- Manufacturer
- 81349 - Military Specifications (Active)
- Definitive Standard
- Definitive Standard
- MIL-R-26/5
- 81349 - Military Specifications (Active)
- Incomplete Standard
- Incomplete Standard
Datasheet 5905-01-381-8876
- Characteristic
- Specifications
- Electrical Resistance [AAPP]
- Specifications
- 0.300 Ohms
- Body Diameter [ABPM]
- 0.094 Inches Nominal
- Body Length [ADAQ]
- 0.406 Inches Nominal
- Inclosure Method [AAQZ]
- Encased
- Power Dissipation Rating In Watts [AEFB]
- 1.000 Free Air
- Reliability Indicator [AARG]
- Not Established
- Resistance Tolerance In Percent [AAPQ]
- -1.000/+1.000
- Specification/Standard Data [ZZZK]
- 81349-Mil-R-26/5 Government Specification
- Style Designator [STYL]
- Axial Terminal Each End
- Terminal Length [ABJT]
- 1.750 Inches Nominal
- Terminal Type [AARB]
- Wire Lead
- Test Data Document [TEST]
- 81349-Mil-R-26 Specification (Includes Engineering Type Bulletins, Brochures,Etc., That Reflect Specification Type Data In Specification Format; Excludes Commercial Catalogs, Industry Directories, And Similar Trade Publications, Reflecting General Type Data On Certain Environmental And Performance Requirements And Test Conditions That Are Shown As "Typical", "Average", "Nominal", Etc.).