Premium Information is available for this item - Upgrade for $1 a day
5905-01-287-4344
Nonprecision Wire Wound Variable Resistor
5905012874344 012874344
A resistor in which a sliding or rolling contact moves over an exposed area of the resistive element to change the ohmic value of the output. The functional tolerance (linearity), if given, of the output is greater than plus of minus 1 percent on linear outputs. Specified outputs such as sine, cosine, tangent, etc., shall be considered to be precision. For items having manually positioned taps designed to be set and fixed prior to use, see RESISTOR, ADJUSTABLE. For items with step by step variation, see RHEOSTAT and RESISTOR, STEP BY STEP. For tandem-mounted items designed to function together as an attenuator (and rated accordingly), see ATTENUATOR, VARIABLE. Excludes RESISTOR (1), VARIABLE, NONWIRE WOUND, NONPRECISION; RESISTOR (1), VARIABLE, NONWIRE WOUND, PRECISION; and RESISTOR (1), VARIABLE, WIRE WOUND, PRECISION. View more Nonprecision Wire Wound Variable Resistor
August 2025
5

Marketplace 5905-01-287-4344
Request a Quotation from participating marketplace vendors
Related Documents 5905-01-287-4344 5+ Documents (More...)
Request a Quotation from participating marketplace vendors Request Updated Every Day 5905-01-287-4344
RQST Updated Every Day 5905-01-287-4344 RQST NE Related Documents 5905-01-287-4344 3+ Documents ( More
Nonprecision Wire Wound Variable Resistor Documents 5905-01-287-4344 1+ Documents ( More https/
Nonprecision Wire Wound Variable Resistor 9999-99-109-4195 5905-00-224-5232 5905-01-287-4344 https
Restrictions 5905-01-287-4344
5905-01-287-4344 is a Nonprecision Wire Wound Variable Resistor that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. This item does not contain a precious metal.
Management Data 5905-01-287-4344
- Effective Date
- Organization
- Unit of Issue
- Unit Price
- Qty Unit Pack
- Unit of Issue
- Sep 2006
- Department of the Army (DA)
- EA
- Subscribe
- 1
- EA
- MOE
- USC
- Code
- Statement
- Order of Use
- Jump To Code
- Qty Per Assy
- UOM
- Technical Document
- Quantative Expression
- Code
- Department of the Air Force (DF)
- F
- V
- Discontinued Without Replacement
- V
- Department of the Navy (DN)
- N
- V
- Discontinued Without Replacement
- V
- Defense Logistics Agency (DS)
- I
- V
- Discontinued Without Replacement
- V
Army
- Materiel Category and Inventory Manager:
- C
- Medical/Dental Materiel
- Appropriation and Budget Activity:
- 2
- Stock Fund Secondary Items
- Management Inventory Segment:
- 2
- Non-Repairable Items(Exclusive of Insurance and Provisioning Items)
This code will be used to identify items, which are not reparable.
- Weapons System / End Item / Homogeneous Group:
- 03
- DLA/GSA Material
Not Potency Dated
- Accounting Requirements:
- X
- Expendable item.An item of Army property coded with an ARC of X in the AMDF. Expendable items require no formal accountability after issue from a stock record account.Commercial and fabricated items similar to items coded X in the AMDF are considered expendable items.
Navy
- Cognizance:
- 9L
Similar Supply Items to 5905-01-287-4344

















