Premium Information is available for this item - Upgrade for $1 a day
5905-01-034-0560
Nonprecision Nonwire Wound Variable Resistor
5905010340560 010340560 949-1-1-504
A resistor in which a sliding or rolling contact moves over an exposed area of the resistive element to change the ohmic value of the output. The functional tolerance (linearity), if given, of the output is greater than plus or minus 1 percent on linear outputs. Specified outputs such as sine, cosine, tangent, etc., shall be considered to be precision. For items having manually positioned taps designed to be set and fixed prior to use, see RESISTOR, ADJUSTABLE. For items with step by step variation, see RHEOSTAT and RESISTOR, STEP BY STEP. For tandem-mounted items designed to function together as an attenuator (and rated accordingly), see ATTENUATOR, VARIABLE. Excludes RESISTOR (1), VARIABLE, WIRE WOUND, NONPRECISION; RESISTOR (1), VARIABLE, NONWIRE WOUND PRECISION; and RESISTOR (1), VARIABLE, WIRE WOUND, PRECISION. View more Nonprecision Nonwire Wound Variable Resistor
![]()
January 2023
10


Marketplace 5905-01-034-0560
Request a Quotation from participating marketplace vendors
Related Documents 5905-01-034-0560 1+ Documents (More...)
Every Day 5905-01-034- 0560 RQST NE Related Documents RQST NE Updated Every Day 5905-01-034-0560 RQST
Updated Every Day 5905 Day 5905-01-034-0560 RQST NE Restrictions Restrictions 5905-01-034-0560 DEMIL
Restrictions 5905-01-034-0560
5905-01-034-0560 is a Nonprecision Nonwire Wound Variable Resistor that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. The precious metals content of this item is unknown.
Import and Export 5905-01-034-0560
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 5905-01-034-0560
- Canada (ZC01)
- Effective Date:
- 1 Apr 1991
Approved Sources 5905-01-034-0560
- Part Number
- Manufacturer
- Status
- 949-1-1-504
- Manufacturer
- 02111 - Vishay Sprague Inc (Active)
- Primary Buy
- Primary Buy
Datasheet 5905-01-034-0560
- Characteristic
- Specifications
- FIIG
- Specifications
- A002A0
- Effective Electrical Rotation In Deg Angular Rotation [AEFH]
- 7920.0 Nominal
- Electrical Resistance Per Section [CQCC]
- 500.0 Kilohms Single Section
- Actuator Travel Control Feature [CRSX]
- Clutch
- Actuator Type [AEFD]
- Single Shaft
- Ambient Temp In Deg Celsius Per Section At Full Rated Power [CSDH]
- 70.0 Single Section
- Ambient Temp In Deg Celsius Per Section At Zero Percent Rated Power [CQGN]
- 105.0 Single Section
- Body Height [ADAU]
- 0.312 Inches Nominal
- Body Length [ADAQ]
- 1.250 Inches Nominal
- Body Width [ADAT]
- 0.280 Inches Nominal
- Body Style [AAQL]
- Rectangular W/Mounting Holes/Slots
- Mounting Facility Quantity [AKPV]
- 2
- Mounting Hole Diameter [ABTB]
- 0.093 Inches Nominal
- Mounting Method [AXGY]
- Terminal And Unthreaded Hole
- Lateral Distance Between Mounting Hole Centers [AGTP]
- 1.000 Inches Nominal
- Power Dissipation Rating Per Section In Watts [CRGD]
- 0.75 Free Air Single Section
- Reliability Indicator [AARG]
- Not Established
- Resistance Tolerance Per Section In Percent [CRSS]
- -20.0 To 20.0 Single Section
- Rotary Actuator Travel In Angular Deg [CQCK]
- 7920.0 Nominal
- Section Quantity [AAPN]
- 1
- Shaft Diameter [ABWV]
- 0.125 Inches Nominal
- Shaft Length [ABXF]
- 0.062 Inches Nominal
- Shaft Style [AEDX]
- Round, Slotted
- Temp Coefficient Of Resistance Per Section In Ppm Per Deg Celsius [CRFJ]
- -100.0 To 100.0 Single Section
- Terminal Location [APXH]
- Rear End
- Terminal Type And Quantity [TTQY]
- 3 Wire Lead
Similar Supply Items to 5905-01-034-0560


















Freight Information 5905-01-034-0560
5905-01-034-0560 has freight characteristics.. 5905-01-034-0560 has a variance between NMFC and UFC when transported by rail and the description should be consulted.