5905-00-999-4670
Nonprecision Wire Wound Variable Resistor
5905009994670 009994670 257903
A resistor in which a sliding or rolling contact moves over an exposed area of the resistive element to change the ohmic value of the output. The functional tolerance (linearity), if given, of the output is greater than plus of minus 1 percent on linear outputs. Specified outputs such as sine, cosine, tangent, etc., shall be considered to be precision. For items having manually positioned taps designed to be set and fixed prior to use, see RESISTOR, ADJUSTABLE. For items with step by step variation, see RHEOSTAT and RESISTOR, STEP BY STEP. For tandem-mounted items designed to function together as an attenuator (and rated accordingly), see ATTENUATOR, VARIABLE. Excludes RESISTOR (1), VARIABLE, NONWIRE WOUND, NONPRECISION; RESISTOR (1), VARIABLE, NONWIRE WOUND, PRECISION; and RESISTOR (1), VARIABLE, WIRE WOUND, PRECISION. View more Nonprecision Wire Wound Variable Resistor
November 2023
6
Marketplace 5905-00-999-4670
Request a Quotation from participating marketplace vendors
Related Documents 5905-00-999-4670 5+ Documents (More...)
your web browser . 5905-00-999-4670Nonprecision Wire Wound Variable Resistor5905009994670 009994670
257903 (Active) Primary Buy RNCC 3 RNVC 2 DAC 5 257903 36378 - Raytheon Technical Services Company (Replaced
3805-14-499-7854 3805144997854 144997854 DOUILLE https//www.nsnlookup.com /fsg-59/fsc-5905/us 5905-00-999-4670
Resistor your web browser . 5905-00-999-4670Nonprecision Wire Wound Variable Resistor5905009994670 009994670
https//www.nsnlookup.com /fsg-76/fsc-7690/fr 7690-14-377-3771 Decal 7690143773771 143773771,BEG30C,257903
enable JavaScript in your web browser . 7690-14-377-3771Decal7690143773771 143773771 BEG30C 257903 257303
Restrictions 5905-00-999-4670
5905-00-999-4670 is a Nonprecision Wire Wound Variable Resistor that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. The precious metals content of this item is unknown.
Approved Sources 5905-00-999-4670
- Part Number
- Manufacturer
- Status
- 257903
- Manufacturer
- 1PQF4 - Cae Usa Inc. (Active)
- Primary Buy
- Primary Buy
- 257903
- 36378 - Raytheon Technical Services Company (Replaced)
- Canceled/Obsolete
- Canceled/Obsolete