Premium Information is available for this item - Upgrade for $1 a day
5905-00-901-6493
Noninductive Wire Wound Fixed Resistor
5905009016493 009016493 136E 842450-1 136E3401D WM1-2 3401D
A resistor whose ohmic value cannot be adjusted or varied. The resistance element consists of high resistance wire (or ribbon) either wound on an insulated form or constructed so as to be self supporting. Opposition to the flow of current is an inherent property of the resistance wire and is manifest by the heat dissipation in the resistor. Excludes SUPPRESSOR, IGNITION INTERFERENCE. View more Wire Wound Fixed Resistor
![]()
November 2023
32

Marketplace 5905-00-901-6493
Request a Quotation from participating marketplace vendors
Related Documents 5905-00-901-6493 5+ Documents (More...)
RQST NE Updated Every Day 5905-00-901-6493 RQST Updated Every Day 5905-00-901-6493 RQST NE Related
Documents 5905-00-901-6493 5+ Documents ( More... ) https//www.nsnlookup.com /fsg-59/fsc-5905/us 5905
Quotation Subscribe to View Vendor Details... 842450-1 GASKET 154 EA NS Request Quotation Subscribe
to View Vendor Details... 842450-1 GASKET 5 EA NS Request Quotation Subscribe to View Vendor Details.
www.nsnlookup.com /fsg-59/fsc-5930/de 5930-12-199-5504 https//www.nsnlookup.com /fsg-59/fsc-5905/us 5905-00-901-6493
Noninductive Wire Wound Fixed Resistor,136E Request Quotation Subscribe to View Vendor Details.
5821/fr 5821-14-042-4152 Radio Receiver-Transmitter 5821140424152 9595 102 023129595-102-02312TRAP-136E
5821-14-042-4152Radio Receiver-Transmitter5821140424152 1404241529595 102 023129595-102-02312TRAP-136E
4J1131-136E Managed by United States NSN Created on 23 Jul 1981 Data Last Changed November 2023 NATO
Buy RNCC 5 RNVC 2 DAC 5 4J31131-136E 99115 - Honeycomb Company Of America, Inc.
Restrictions 5905-00-901-6493
5905-00-901-6493 is a Noninductive Wire Wound Fixed Resistor that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. This item has been confirmed as a Critical Munitions List Item or a Sensitive Commerce Control List Item and cannot be in the possession of any party anywhere in the World who is not an authorized NATO Government. Any other possessor of this item should mutilate it now as possession violates international and local laws. This item is a confirmed Commerce Control List Item (CCLI). This item is not suspected to be hazardous. The precious metals content of this item is unknown. This item is sensitive to Electrostatic Discharge.
Import and Export 5905-00-901-6493
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 5905-00-901-6493
- US Air Force (FXGX)
- Effective Date:
- 1 Jul 2005
- Former MOE Rule:
- FXTX
- US Navy (N9BN)
- Effective Date:
- 1 Jul 2005
- Former MOE Rule:
- N9ND
- Supplementary Collaborators:
- KE
- Poland (WP01)
- Effective Date:
- 1 Jul 2011
- Brazil (YA01)
- Effective Date:
- 1 Oct 2000
- Israel (YD01)
- Effective Date:
- 1 Feb 2017
- Canada (ZC01)
- Effective Date:
- 1 Apr 1991
- New Zealand (ZE01)
- Effective Date:
- 1 Apr 1991
- Portugal (ZP01)
- Effective Date:
- 1 Apr 1991
- Turkey (ZW01)
- Effective Date:
- 1 Nov 2005
Approved Sources 5905-00-901-6493
- Part Number
- Manufacturer
- Status
- 842450-1
- Manufacturer
- 07187 - Honeywell International Inc. (Active)
- Primary Buy
- Primary Buy
- 136E3401D
- 54294 - Shallcross Inc (Active)
- Secondary Buy
- Secondary Buy
- 842450-1
- 0SML3 - Aero International, Llc (Active)
- Secondary Buy
- Secondary Buy
- 842450-1
- 56232 - Lockheed Martin Corporation (Active)
- Canceled/Obsolete
- Canceled/Obsolete
- WM1-2 3401D
- 80031 - Mepco/Electra Inc (Obsolete)
- Canceled/Obsolete
- Canceled/Obsolete
- 136E
- 54294 - Shallcross Inc (Active)
- Advisory Reference
- Advisory Reference
Datasheet 5905-00-901-6493
- Characteristic
- Specifications
- FIIG
- Specifications
- A001A0
- Electrical Resistance [AAPP]
- 3.400 Kilohms
- Ambient Temp In Deg Celsius At Zero Percent Rated Power [AAQG]
- 105.0
- Ambient Temp In Deg Celsius At Full Rated Power [AAQF]
- 85.0
- Body Diameter [ABPM]
- 0.270 Inches Maximum
- Body Length [ADAQ]
- 0.447 Inches Maximum
- Cubic Measure [CBME]
- 0.025 Cubic Inches
- Inclosure Method [AAQZ]
- Encapsulated
- Power Dissipation Rating In Watts [AEFB]
- 0.100 Free Air
- Reliability Indicator [AARG]
- Not Established
- Resistance Tolerance In Percent [AAPQ]
- -0.500/+0.500
- Unpackaged Unit Weight [PKWT]
- 2.5 Grams
- Style Designator [STYL]
- Axial Terminals One End
- Temp Coefficient Of Resistance In Ppm Per Deg Celsius [AAPE]
- -20.0/+20.0
- Temp Range Of Temp Coefficient In Deg Celsius [AAQH]
- -55.0/+105.0
- Terminal Length [ABJT]
- 1.250 Inches Minimum
- Terminal Type [AARB]
- Wire Lead
Weapon Systems (WSDC) 5905-00-901-6493
DLA Procurement Analysis 5905-00-901-6493
- Last Stock Position:
- 19 In Stock
- DLA Administrative Lead Time:
- Subscribe
- DLA Production Lead Time:
- Subscribe
Management Data 5905-00-901-6493
Navy
- Cognizance:
- 9B
- Navy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Similar Supply Items to 5905-00-901-6493


















Freight Information 5905-00-901-6493
5905-00-901-6493 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 062960. A Sub NMFC of X. It has a NMFC Description of REOSTATS/PARTS NOI. 5905-00-901-6493 is rated as class 77.5 when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 35140 which rates the freight between FCL and LCL. 5905-00-901-6493 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 72D for ocean manifesting and military sealift. 5905-00-901-6493 is classified as an Electrostatic Sensitive Device (ESD) when transported by water. 5905-00-901-6493 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.
Packaging Data 5905-00-901-6493
- Responsible Activity
- Packaging Data Source
- Primary Inventory Control Activity (PICA)
- --
Item Pack Level (Unpackaged)
- Item Size
- Item Weight
- Characteristics
- Weight/Dimensions Category
- Fragility
- Item Preservation
- Item Weight
- --
- --
- --
- 0.25 lb or less, one dimension 2" or less, other dimensions less than 24"
- 85 to 110G
- No Requirement
- --
Unit Pack Level (Packaged)
- Quantity per Pack
- Unit Size
- Unit Weight
- Unit Cube
- Preservation Method
- Cleaning/Drying
- Unit Size
- 1
- --
- --
- --
- --
- --
- --
- Preservation Material
- Wrapping Material
- Cushioning/Dunnage
- Cushioning Thickness
- Container
- Special Marking
- Wrapping Material
- --
- --
- --
- --
- --
- Special requirements
- --
Intermediate Pack Level
- Quantity of Unit Packs
- Container
- See Method of Preservation
- --
Procurement History 5905-00-901-6493 1 Records
Contracting Technical Data File (CTDF) 5905-00-901-6493 October 2021
Criticality and Quality
- Critical Item Code:
- X
- Flight Safety:
- Life Support:
- Certified Samples:
- Serialization:
- First Article Test (FAT):
- Certificate of Quality Compliance:
- Production Lot Testing:
- Special Testing:
- Qualified Products List (QPL):
Commercial Properties
- Government Furnished Material:
- Government Furnished Tooling:
- Government Furnished Property:
- Price Evaluation Code:
- Diminshing Manufacturing Sources:
- Warranty:
- Commerical Off The Shelf (COTS):
- End Item Application:
- Auctioning Candidate:
- Source of Procurement:
- Contract Option:
Restrictions
- Boeing Rights Guard:
- Export Controlled:
- Controlled Technical Data Package (TDP):
- Restricted Technical Data Package (TDP):
- Contains Classified Material
- Weapons System Indicator Code (WSIC):
- F
Packaging Requirements
- Packaging Determination Table:
- Packaging Review Code:
- Special Packaging Instruction Number (SPIN):
- Special Packaging Instruction Number Revision:
- Special Packaging Instruction Number Date:
- Pallet Reference Number Required: