Premium Information is available for this item - Upgrade for $1 a day

5905-00-581-1997

Inductive Wire Wound Fixed Resistor

5905005811997 005811997 IR107-46R4F

A resistor whose ohmic value cannot be adjusted or varied. The resistance element consists of high resistance wire (or ribbon) either wound on an insulated form or constructed so as to be self-supporting. The item must have inherent characteristics of inducing self-inductance. Opposition to current flow is an inherent property of the resistance wire and is manifested by the heat dissipation in the resistor. Exclut s SUPPRESSOR, IGNITION INTERFERENCE. See also RESISTOR (1), FIXED, WIRE WOUND, NONINDUCTIVE. View more Inductive Wire Wound Fixed Resistor

5905-00-581-1997 RESISTOR,FIXED,WIRE WOUND,INDUCTIVE 5905005811997 005811997

Managed by United States
NSN Created on 1 Jan 1963
Data Last Changed
May 2023
NATO Update Count
24
NATO Data Quality
STYL Style 14 for 5905-00-581-1997 1/1
NSN 5905-00-581-1997 (Identification) 1/1

5905-00-581-1997 Stock and Availability Marketplace 5905-00-581-1997

Need Help?
Request a Quotation from participating marketplace vendors
eBay Updated Every Day
5905-00-581-1997 RQST NE eBay
eBay Updated Every Day
5905-00-581-1997 RQST eBay
Amazon Updated Every Day
5905-00-581-1997 RQST NE Amazon

5905-00-581-1997 Related Documents Related Documents 5905-00-581-1997 1+ Documents (More...)

IR107-46R4F A resistor whose ohmic value cannot be adjusted or varied.
United States (US) 4. 5905-00-581-1997 Marketplace Restrictions Approved Sources Datasheet Management
RQST NE Updated Every Day 5905-00-581-1997 RQST Updated Every Day 5905-00-581-1997 RQST NE Related Documents

5905-00-581-1997 Demil Restrictions 5905-00-581-1997

DEMIL: A | DEMILI: | CRITICALITY: X | HMIC: N | PMIC: U | EDC: A | ADPEC:

5905-00-581-1997 is a Inductive Wire Wound Fixed Resistor that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. The precious metals content of this item is unknown.

5905-00-581-1997 HTS and ScheduleB Import and Export 5905-00-581-1997

5905-00-581-1997 End Users End Users 5905-00-581-1997

Spain (YB)
Spain (YB01)
Effective Date:
1 Sep 2009
Canada (ZC)
Canada (ZC01)
Effective Date:
1 Apr 1991
France (ZF)
France (ZF01)
Effective Date:
1 Apr 1991
Republic of Korea (ZH)
Republic of Korea (ZH01)
Effective Date:
1 Apr 1991
Portugal (ZP)
Portugal (ZP01)
Effective Date:
1 Apr 1991
Turkey (ZW)
Turkey (ZW01)
Effective Date:
1 Nov 2005

5905-00-581-1997 Manufacturers Approved Sources 5905-00-581-1997

5905-00-581-1997 Technical Data Datasheet 5905-00-581-1997

Characteristic
Specifications
FIIG
A001A0
Electrical Resistance [AAPP]
46.400 Ohms
Ambient Temp In Deg Celsius At Full Rated Power [AAQF]
25.0
Ambient Temp In Deg Celsius At Zero Percent Rated Power [AAQG]
65.0
Body Diameter [ABPM]
0.109 Inches Nominal
Body Length [ADAQ]
0.375 Inches Nominal
Inclosure Method [AAQZ]
Encapsulated
Power Dissipation Rating In Watts [AEFB]
0.125 Free Air
Reliability Indicator [AARG]
Not Established
Resistance Tolerance In Percent [AAPQ]
-1.000/+1.000
Style Designator [STYL]
Axial Terminal Each End
Terminal Type [AARB]
Wire Lead

5905-00-581-1997 Stock, Inventory and Procurement DLA Procurement Analysis 5905-00-581-1997

DLA Administrative Lead Time:
Subscribe
DLA Production Lead Time:
Subscribe
Subscribe to View DLA Inventory and Forecast...

5905-00-581-1997 Management Data Management Data 5905-00-581-1997

Effective Date
Organization
Unit of Issue
Unit Price
Qty Unit Pack
Apr 2009
Defense Logistics Agency (DS)
EA
Subscribe
1
MOE
USC
Code
Statement
Order of Use
Jump To Code
Qty Per Assy
UOM
Technical Document
Quantative Expression
Defense Logistics Agency (DS)
I
Z
Discontinued-Use 5905-01-188-6061

5905-00-581-1997 Related Items NATO Stock Numbers Related to 5905-00-581-1997

5905-00-581-1997 Freight Data Freight Information 5905-00-581-1997

5905-00-581-1997 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 062960. A Sub NMFC of X. It has a NMFC Description of REOSTATS/PARTS NOI. 5905-00-581-1997 is rated as class 77.5 when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 35140 which rates the freight between FCL and LCL. 5905-00-581-1997 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 72D for ocean manifesting and military sealift. 5905-00-581-1997 is not classified as a special type of cargo when transported by water. 5905-00-581-1997 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.

5905-00-581-1997 Contracting Technical Data File (CTDF) Contracting Technical Data File (CTDF) 5905-00-581-1997 October 2021

Criticality and Quality

Critical Item Code:
Flight Safety:
Life Support:
Certified Samples:
Serialization:
First Article Test (FAT):
Certificate of Quality Compliance:
Production Lot Testing:
Special Testing:
Qualified Products List (QPL):

Commercial Properties

Government Furnished Material:
Government Furnished Tooling:
Government Furnished Property:
Price Evaluation Code:
Diminshing Manufacturing Sources:
Warranty:
Commerical Off The Shelf (COTS):
End Item Application:
Auctioning Candidate:
Source of Procurement:
Contract Option:

Restrictions

Boeing Rights Guard:
Export Controlled:
Controlled Technical Data Package (TDP):
Restricted Technical Data Package (TDP):
Contains Classified Material
Weapons System Indicator Code (WSIC):
N

Packaging Requirements

Packaging Determination Table:
Packaging Review Code:
Special Packaging Instruction Number (SPIN):
Special Packaging Instruction Number Revision:
Special Packaging Instruction Number Date:
Pallet Reference Number Required: