5905-00-477-4722
Precision Wire Wound Variable Resistor
5905004774722 004774722 EPA1S205 500-8355
A resistor in which a sliding or rolling contact moves over an exposed area of the resistive element to change the ohmic value of the output. The functional tolerance (linearity) of the output is equal to or less than plus or munus 1 percent on linear outputs. Specified outputs such as sine, cosine, tangent, etc., shall be considered to be precision. For items having manually positioned taps designed to be set and fixed prior to use, see RESISTOR, ADJUSTABLE, For items with step by step variation, see RHEOSTAT and RESISTOR, STEP BY STEP. For tandem-mounted items designed to function together as an attenuator (and rated accordingly), see ATTENUATOR, VARIABLE. Excludes RESISTOR (1), VARIABLE, NONWIRE WOUND, NONPRECISION; RESISTOR (1), VARIABLE, NONWIRE WOUND, PRECISION; and RESISTOR (1), VARIABLE, WIRE WOUND, NONPRECISION. View more Precision Wire Wound Variable Resistor
November 2023
4
Marketplace 5905-00-477-4722
Request a Quotation from participating marketplace vendors
Related Documents 5905-00-477-4722 5+ Documents (More...)
Circuit Breaker 5925375008355 375008355 5925-37-500-8355 5925375008355 375008355 is a device with means
/fsg-48/fsc-4810/us
BUY NE FedMall Updated Every Day 4810-01-500-8355 RQST NE Updated Every Day 4810-01-500-8355 RQST Updated
Every Day 4810-01-500-8355 RQST NE Related Documents 4810-01-500-8355 2+ Documents ( More... ) https
Request a Quotation from participating marketplace vendors Request Updated Every Day 4710-14-500-8355
RQST NE Updated Every Day 4710-14-500-8355 RQST Updated Every Day 4710-14-500-8355 RQST NE Restrictions
Request a Quotation from participating marketplace vendors Request Updated Every Day 4150-99-500-8355
RQST NE Updated Every Day 4150-99-500-8355 RQST Updated Every Day 4150-99-500-8355 RQST NE Restrictions
Restrictions 5905-00-477-4722
5905-00-477-4722 is a Precision Wire Wound Variable Resistor that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. The precious metals content of this item is unknown.
Approved Sources 5905-00-477-4722
- Part Number
- Manufacturer
- Status
- EPA1S205
- Manufacturer
- 99251 - Mission Systems Davenport Inc. (Active)
- Source Control
- Source Control
- 500-8355
- 02111 - Vishay Sprague Inc (Active)
- Primary Buy
- Primary Buy