Premium Information is available for this item - Upgrade for $1 a day
5905-00-455-6812
Nonprecision Wire Wound Variable Resistor
5905004556812 004556812 67C700053-13 3000P1-103
A resistor in which a sliding or rolling contact moves over an exposed area of the resistive element to change the ohmic value of the output. The functional tolerance (linearity), if given, of the output is greater than plus of minus 1 percent on linear outputs. Specified outputs such as sine, cosine, tangent, etc., shall be considered to be precision. For items having manually positioned taps designed to be set and fixed prior to use, see RESISTOR, ADJUSTABLE. For items with step by step variation, see RHEOSTAT and RESISTOR, STEP BY STEP. For tandem-mounted items designed to function together as an attenuator (and rated accordingly), see ATTENUATOR, VARIABLE. Excludes RESISTOR (1), VARIABLE, NONWIRE WOUND, NONPRECISION; RESISTOR (1), VARIABLE, NONWIRE WOUND, PRECISION; and RESISTOR (1), VARIABLE, WIRE WOUND, PRECISION. View more Nonprecision Wire Wound Variable Resistor
November 2023
5

Marketplace 5905-00-455-6812
Request a Quotation from participating marketplace vendors
Related Documents 5905-00-455-6812 2+ Documents (More...)
United States (US) 4. 5905-00-455-6812 Marketplace Restrictions Approved Sources Datasheet Management
RQST NE Updated Every Day 5905-00-455-6812 RQST Updated Every Day 5905-00-455-6812 RQST NE Related
a Quotation from participating marketplace vendors Request Subscribe to View Vendor Details... 3000P1-103
Variable Resistor Upgrade 5905-00-455-6812Nonprecision Wire Wound Variable Resistor5905004556812 004556812
Restrictions 5905-00-455-6812
5905-00-455-6812 is a Nonprecision Wire Wound Variable Resistor that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. This item does not contain a precious metal.
Approved Sources 5905-00-455-6812
- Part Number
- Manufacturer
- Status
- 67C700053-13
- Manufacturer
- 02106 - Mrl Inc (Obsolete)
- Source Control
- Source Control
- 3000P1-103
- 80294 - Bourns Instruments Inc (Obsolete)
- Primary Buy
- Primary Buy
Management Data 5905-00-455-6812
- Effective Date
- Organization
- Unit of Issue
- Unit Price
- Qty Unit Pack
- Unit of Issue
- Dec 2001
- Department of the Navy (DN)
- EA
- Subscribe
- 1
- EA
- MOE
- USC
- Code
- Statement
- Order of Use
- Jump To Code
- Qty Per Assy
- UOM
- Technical Document
- Quantative Expression
- Code
- Department of the Navy (DN)
- I
- V
- Discontinued Without Replacement
- V
- Department of the Navy (DN)
- N
- N
- Disposal
- N
Navy
- Cognizance:
- 1R
- Aeronautical, photographic, and meteorological material (consumable or expense type material)
Naval Inventory Control Point, Philadelphia
- Special Material ID:
- EF
- Fighter Aircraft (F8)
- Issue, Repair, Requisition Restriction Code:
- 00
- No Restriction
- Special Material Content:
- 9
- Non-Hazardous or Non-Sensitive Item