5905-00-408-2214
Nonprecision Nonwire Wound Variable Resistor
5905004082214 004082214 2605585-10 450-00-103
A resistor in which a sliding or rolling contact moves over an exposed area of the resistive element to change the ohmic value of the output. The functional tolerance (linearity), if given, of the output is greater than plus or minus 1 percent on linear outputs. Specified outputs such as sine, cosine, tangent, etc., shall be considered to be precision. For items having manually positioned taps designed to be set and fixed prior to use, see RESISTOR, ADJUSTABLE. For items with step by step variation, see RHEOSTAT and RESISTOR, STEP BY STEP. For tandem-mounted items designed to function together as an attenuator (and rated accordingly), see ATTENUATOR, VARIABLE. Excludes RESISTOR (1), VARIABLE, WIRE WOUND, NONPRECISION; RESISTOR (1), VARIABLE, NONWIRE WOUND PRECISION; and RESISTOR (1), VARIABLE, WIRE WOUND, PRECISION. View more Nonprecision Nonwire Wound Variable Resistor
November 2023
15
Marketplace 5905-00-408-2214
Request a Quotation from participating marketplace vendors
Related Documents 5905-00-408-2214 5+ Documents (More...)
2605585-10 MIL-R-39035/1 MIL-R-39035/1 RESISTOR,VARIABLE,NONWIRE WOUND,NONPRECISION RQST NS Request
-033-3849 5905000333849 000333849 MIL-R-39035/1 https//www.nsnlookup.com /fsg-59/fsc-5905/us 5905-00-408-2214
5905004082214 004082214,2605585-10 5905-00-408-2214 5905004082214 004082214 is a resistor in which
5905004082214 004082214,2605585-10 Variable Resistor5905002643530 002643530 3059L-1-103 G310180
-7 41576-324-00-2 450-00-103 2605585-10 MIL-R-39035/1 A resistor in which a sliding or rolling contact
2605585-10 MIL-R-39035/1 A resistor in which a sliding or rolling contact moves over an exposed
2 MIL-R-39035/1 81349 - Military Specifications (Active) Canceled/Obsolete RNCC 5 RNVC 9 DAC E 450-00-103
Restrictions 5905-00-408-2214
5905-00-408-2214 is a Nonprecision Nonwire Wound Variable Resistor that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. The precious metals content of this item is unknown.
Approved Sources 5905-00-408-2214
- Part Number
- Manufacturer
- Status
- 2605585-10
- Manufacturer
- 06424 - Alliant Techsystems Operations Llc (Active)
- Primary Buy
- Primary Buy
- 450-00-103
- 84048 - Vernitron Corp Vrn International Div (Active)
- Secondary Buy
- Secondary Buy