Premium Information is available for this item - Upgrade for $1 a day
5905-00-283-4313
Nonprecision Nonwire Wound Variable Resistor
5905002834313 002834313 JJU2521
A resistor in which a sliding or rolling contact moves over an exposed area of the resistive element to change the ohmic value of the output. The functional tolerance (linearity), if given, of the output is greater than plus or minus 1 percent on linear outputs. Specified outputs such as sine, cosine, tangent, etc., shall be considered to be precision. For items having manually positioned taps designed to be set and fixed prior to use, see RESISTOR, ADJUSTABLE. For items with step by step variation, see RHEOSTAT and RESISTOR, STEP BY STEP. For tandem-mounted items designed to function together as an attenuator (and rated accordingly), see ATTENUATOR, VARIABLE. Excludes RESISTOR (1), VARIABLE, WIRE WOUND, NONPRECISION; RESISTOR (1), VARIABLE, NONWIRE WOUND PRECISION; and RESISTOR (1), VARIABLE, WIRE WOUND, PRECISION. View more Nonprecision Nonwire Wound Variable Resistor
November 2023
12

Marketplace 5905-00-283-4313
Request a Quotation from participating marketplace vendors






Related Documents 5905-00-283-4313 3+ Documents (More...)
Details... 5905-00-283-4313 RESISTOR,VARIABLE,NONWIRE WOUND,NONPRECISION 2 EA NS Request Quotation 5905
RQST NE Updated Every Day 5905-00-283-4313 RQST Updated Every Day 5905-00-283-4313 RQST NE Related
5905002834313 002834313,JJU2521 Account Upgrade 5905-00-283-4313Nonprecision Nonwire Wound Variable
Resistor5905002834313 002834313 JJU2521 JJU2521 RESISTOR,VARIABLE,NONWIRE WOUND,NONPRECISION 70 EA NS
Restrictions 5905-00-283-4313
5905-00-283-4313 is a Nonprecision Nonwire Wound Variable Resistor that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. The precious metals content of this item is unknown.
Approved Sources 5905-00-283-4313
- Part Number
- Manufacturer
- Status
- JJU2521
- Manufacturer
- 12697 - Clarostat Sensors And Controls (Active)
- Incomplete Reference
- Incomplete Reference
- JJU2521
- 01121 - Rockwell Automation, Inc. (Active)
- Canceled/Obsolete
- Canceled/Obsolete
Management Data 5905-00-283-4313
- Effective Date
- Organization
- Unit of Issue
- Unit Price
- Qty Unit Pack
- Unit of Issue
- Oct 2000
- Department of the Navy (DN)
- EA
- Subscribe
- 1
- EA
- MOE
- USC
- Code
- Statement
- Order of Use
- Jump To Code
- Qty Per Assy
- UOM
- Technical Document
- Quantative Expression
- Code
- Department of the Navy (DN)
- N
- Z
- Discontinued-Use 5905-01-133-9064
- Z
Navy
- Cognizance:
- 9N
Similar Supply Items to 5905-00-283-4313

















