Premium Information is available for this item - Upgrade for $1 a day
5905-00-265-1702
Precision Wire Wound Variable Resistor
5905002651702 002651702 1037C831REVA 3520S1-500
A resistor in which a sliding or rolling contact moves over an exposed area of the resistive element to change the ohmic value of the output. The functional tolerance (linearity) of the output is equal to or less than plus or munus 1 percent on linear outputs. Specified outputs such as sine, cosine, tangent, etc., shall be considered to be precision. For items having manually positioned taps designed to be set and fixed prior to use, see RESISTOR, ADJUSTABLE, For items with step by step variation, see RHEOSTAT and RESISTOR, STEP BY STEP. For tandem-mounted items designed to function together as an attenuator (and rated accordingly), see ATTENUATOR, VARIABLE. Excludes RESISTOR (1), VARIABLE, NONWIRE WOUND, NONPRECISION; RESISTOR (1), VARIABLE, NONWIRE WOUND, PRECISION; and RESISTOR (1), VARIABLE, WIRE WOUND, NONPRECISION. View more Precision Wire Wound Variable Resistor
November 2023
6

Marketplace 5905-00-265-1702
Request a Quotation from participating marketplace vendors
Related Documents 5905-00-265-1702 3+ Documents (More...)

/fsg-59/fsc-5905/us
RQST NE Updated Every Day 5905-00-265-1702 RQST Updated Every Day 5905-00-265-1702 RQST NE Related Documents
5905-00-265-1702 3+ Documents ( More... ) https//www.nsnlookup.com /fsg-59/fsc-5905/us 5905-00-265-1702
1037C831REVA 3520S1-500 Resistor Account Upgrade 5905-00-473-3779Nonprecision Wire Wound Variable Resistor5905004733779
Account Upgrade 5905-00-099-4949Nonprecision Wire Wound Variable Resistor5905000994949 000994949 3520S1-500
www.nsnlookup.com /fsg-59/fsc-5905/us 5905-00-099-4949 Nonprecision Wire Wound Variable Resistor 3520S1-500
Restrictions Approved Sources Datasheet Management https//www.nsnlookup.com /fsg-59/fsc-5905/us 5905-00-265-1702
Restrictions 5905-00-265-1702
5905-00-265-1702 is a Precision Wire Wound Variable Resistor that does not have a nuclear hardened feature, but does have another critical feature or features such as tolerance, fit restriction or application. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. The precious metals content of this item is unknown.
Approved Sources 5905-00-265-1702
- Part Number
- Manufacturer
- Status
- 1037C831REVA
- Manufacturer
- 95210 - Peerless Instrument Co., Inc. (Active)
- Incomplete Reference
- Incomplete Reference
- 3520S1-500
- 80294 - Bourns Instruments Inc (Obsolete)
- Incomplete Secondary Reference
- Incomplete Secondary Reference
Management Data 5905-00-265-1702
- Effective Date
- Organization
- Unit of Issue
- Unit Price
- Qty Unit Pack
- Unit of Issue
- Dec 2001
- Department of the Navy (DN)
- EA
- Subscribe
- 1
- EA
- MOE
- USC
- Code
- Statement
- Order of Use
- Jump To Code
- Qty Per Assy
- UOM
- Technical Document
- Quantative Expression
- Code
- Department of the Navy (DN)
- I
- V
- Discontinued Without Replacement
- V
- Department of the Navy (DN)
- N
- N
- Disposal
- N
Navy
- Cognizance:
- 1H
- Consumable material assigned to NAVICP MECH for inventory management
Naval Inventory Control Point, Mechanicsburg
- Special Material ID:
- X3
- Nuclear Reactor Plant (NRP) material under the technical cognizance of the NAVSEA 08 special designed, manufactured and/or treated for use in a NRP or controls thereof. This category includes all other NRP items which are not coded X2 or X4.
- Issue, Repair, Requisition Restriction Code:
- BL
- Submit/refer requisitions to NAVICP MECH. Centralized control for issue of repair parts for specific programs/equipment