Premium Information is available for this item - Upgrade for $1 a day
5905-00-241-3632
Nonprecision Nonwire Wound Variable Resistor
5905002413632 002413632 58PR25K
A resistor in which a sliding or rolling contact moves over an exposed area of the resistive element to change the ohmic value of the output. The functional tolerance (linearity), if given, of the output is greater than plus or minus 1 percent on linear outputs. Specified outputs such as sine, cosine, tangent, etc., shall be considered to be precision. For items having manually positioned taps designed to be set and fixed prior to use, see RESISTOR, ADJUSTABLE. For items with step by step variation, see RHEOSTAT and RESISTOR, STEP BY STEP. For tandem-mounted items designed to function together as an attenuator (and rated accordingly), see ATTENUATOR, VARIABLE. Excludes RESISTOR (1), VARIABLE, WIRE WOUND, NONPRECISION; RESISTOR (1), VARIABLE, NONWIRE WOUND PRECISION; and RESISTOR (1), VARIABLE, WIRE WOUND, PRECISION. View more Nonprecision Nonwire Wound Variable Resistor
November 2023
24
Marketplace 5905-00-241-3632
Request a Quotation from participating marketplace vendors
Related Documents 5905-00-241-3632 5+ Documents (More...)
5905010038276 010038276,MIL-PRF-22097/2 RJR12FY253P 600557 RJ12FY253 78PR25K 78PR25KOHM 5L.5135.001.22 58PR25K
RNVC 8 DAC 4 5L.5135.001.22 D1901 - Hensoldt Sensors Gmbh (Active) Transferred RNCC E RNVC 8 DAC 1 58PR25K
Restrictions 5905-00-241-3632
5905-00-241-3632 is a Nonprecision Nonwire Wound Variable Resistor that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. The precious metals content of this item is unknown.
Approved Sources 5905-00-241-3632
- Part Number
- Manufacturer
- Status
- 58PR25K
- Manufacturer
- 73138 - Bi Technologies Corporation (Active)
- Primary Buy
- Primary Buy
Management Data 5905-00-241-3632
- Effective Date
- Organization
- Unit of Issue
- Unit Price
- Qty Unit Pack
- Unit of Issue
- Oct 1979
- Department of the Navy (DN)
- EA
- Subscribe
- 1
- EA
- MOE
- USC
- Code
- Statement
- Order of Use
- Jump To Code
- Qty Per Assy
- UOM
- Technical Document
- Quantative Expression
- Code
- Department of the Navy (DN)
- N
- V
- Discontinued Without Replacement
- V
Navy
- Cognizance:
- 9N