Premium Information is available for this item - Upgrade for $1 a day
5905-00-233-3506
Precision Nonwire Wound Variable Resistor
5905002333506 002333506 22708-1 7814-10K C603107005
A resistor in which a sliding or rolling contact moves over an exposed area of the resistive element to change the ohmic value of the output. The finctional tolerance (linearity) of the output is equal to or less than plus or minus 1 percent on linear outputs. Specified outputs such as sine, cosine, tangent, etc., shall be considered to be precision. For items having manually postioned taps designed to be set and fixed prior to use, see RESISTOR, ADJUSTABLE. For items with step by step variation, see REHOSTAT and RESISTOR, STEP BY STEP. For tandem-mounted items designed to function together as an attenuator (and rated accordingly), see ATTENUATOR, VARIABLE. Excludes RESISTOR (1), VARIABLE, WIRE WOUND, NONPRECISION; RESISTOR (1), VARIABLE NONWIRE WOUND, NONPRECISION; and RESISTOR (1), VARIABLE, WIRE WOUND, PRECISION. View more Precision Nonwire Wound Variable Resistor
November 2023
5

Marketplace 5905-00-233-3506
Request a Quotation from participating marketplace vendors
Related Documents 5905-00-233-3506 2+ Documents (More...)
United States (US) 4. 5905-00-233-3506 Marketplace Restrictions Approved Sources Datasheet Management
RQST NE Updated Every Day 5905-00-233-3506 RQST Updated Every Day 5905-00-233-3506 RQST NE Related
https//www.nsnlookup.com /fsg-44/fsc-4420/us 4420-01-476-1615 Industrial Fluid Cooler 4420014761615 22708-1
Resistor Account Upgrade 5905-00-233-3506Precision Nonwire Wound Variable Resistor5905002333506 002333506
Restrictions 5905-00-233-3506
5905-00-233-3506 is a Precision Nonwire Wound Variable Resistor that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. The precious metals content of this item is unknown.
Approved Sources 5905-00-233-3506
- Part Number
- Manufacturer
- Status
- C603107005
- Manufacturer
- 88818 - Kearfott Corporation (Active)
- Primary Buy
- Primary Buy
- 22708-1
- 10112 - General Dynamics Motion Control Llc (Active)
- Incomplete Secondary Reference
- Incomplete Secondary Reference
- 7814-10K
- 73138 - Bi Technologies Corporation (Active)
- Incomplete Secondary Reference
- Incomplete Secondary Reference
Similar Supply Items to 5905-00-233-3506