Premium Information is available for this item - Upgrade for $1 a day
5905-00-023-4837
Nonprecision Nonwire Wound Variable Resistor
5905000234837 000234837 2100-0025 JA1N032S152AA 380-1501K 5/8 IN. SHAFT
A resistor in which a sliding or rolling contact moves over an exposed area of the resistive element to change the ohmic value of the output. The functional tolerance (linearity), if given, of the output is greater than plus or minus 1 percent on linear outputs. Specified outputs such as sine, cosine, tangent, etc., shall be considered to be precision. For items having manually positioned taps designed to be set and fixed prior to use, see RESISTOR, ADJUSTABLE. For items with step by step variation, see RHEOSTAT and RESISTOR, STEP BY STEP. For tandem-mounted items designed to function together as an attenuator (and rated accordingly), see ATTENUATOR, VARIABLE. Excludes RESISTOR (1), VARIABLE, WIRE WOUND, NONPRECISION; RESISTOR (1), VARIABLE, NONWIRE WOUND PRECISION; and RESISTOR (1), VARIABLE, WIRE WOUND, PRECISION. View more Nonprecision Nonwire Wound Variable Resistor
May 2023
26


Marketplace 5905-00-023-4837
Request a Quotation from participating marketplace vendors
Related Documents 5905-00-023-4837 5+ Documents (More...)
RQST NE Updated Every Day 5905-00-023-4837 RQST Updated Every Day 5905-00-023-4837 RQST NE Related Documents
RQST NE Updated Every Day 5905-00-023-4837 RQST Updated Every Day 5905-00-023-4837 RQST NE Related Documents
Documents 5905-12-027-5468 2+ Documents ( More https//www.nsnlookup.com /fsg-59/fsc-5905/us 5905-00-023-4837
5905000234837 000234837,2100-0025 Day 5905-00-023-4837 RQST NE Related Documents https//www.nsnlookup.com
5905000234837 000234837,2100-0025 4837Nonprecision Nonwire Wound Variable Resistor5905000234837
000234837 2100-0025 JA1N032S152AA 380-1501K 4837 RQST NE Restrictions https//www.nsnlookup.com https
NONPRECISION 27 EA NS Request Quotation Subscribe to View https//www.nsnlookup.com /fsg-59/fsc-5905/us 5905-00-023-4837
5905000234837 000234837,2100-0025 Account Upgrade 5905-00-023-4837Nonprecision Nonwire Wound Variable
5905000234837 000234837,2100-0025 -00-023-4837Nonprecision Nonwire Wound Variable https//www.nsnlookup.com
Restrictions 5905-00-023-4837
5905-00-023-4837 is a Nonprecision Nonwire Wound Variable Resistor that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. The precious metals content of this item is unknown.
End Users 5905-00-023-4837
- Germany (ZG01)
- Effective Date:
- 1 Nov 2011
- Italy (ZR01)
- Effective Date:
- 1 Jul 1997
- Turkey (ZW01)
- Effective Date:
- 1 Dec 1995
Approved Sources 5905-00-023-4837
- Part Number
- Manufacturer
- Status
- 2100-0025
- Manufacturer
- 1MY97 - Agilent Technologies, Inc. (Active)
- Primary Buy
- Primary Buy
- JA1N032S152AA
- 01121 - Rockwell Automation, Inc. (Active)
- Secondary Buy
- Secondary Buy
- 380-1501K 5/8 IN. SHAFT
- 12697 - Clarostat Sensors And Controls (Active)
- Canceled/Obsolete
- Canceled/Obsolete
- 2100-0025
- 28480 - Hewlett-Packard Company (Active)
- Canceled/Obsolete
- Canceled/Obsolete
Datasheet 5905-00-023-4837
- Characteristic
- Specifications
- FIIG
- Specifications
- A002A0
- Effective Electrical Rotation In Deg Angular Rotation [AEFH]
- 312.0 Nominal
- Electrical Resistance Per Section [CQCC]
- 1.500 Kilohms Single Section
- Actuator Travel Control Feature [CRSX]
- Stops
- Actuator Type [AEFD]
- Single Shaft
- Ambient Temp In Deg Celsius Per Section At Full Rated Power [CSDH]
- 70.0 Single Section
- Ambient Temp In Deg Celsius Per Section At Zero Percent Rated Power [CQGN]
- 105.0 Single Section
- Body Diameter [ABPM]
- 1.156 Inches Nominal
- Body Length [ADAQ]
- 0.625 Inches Nominal
- Body Style [AAQL]
- Cylindrical Bushing Mounted
- Mounting Bushing Length [ADAP]
- 0.500 Inches Nominal
- Mounting Method [AXGY]
- Standard Bushing
- Nonturn Device Location [AEFN]
- At 3 Oclock
- Nonturn Device Radius [AEFP]
- 0.531 Inches Nominal
- Power Dissipation Rating Per Section In Watts [CRGD]
- 2.0 Free Air Single Section
- Reliability Indicator [AARG]
- Not Established
- Resistance Tolerance Per Section In Percent [CRSS]
- -10.0 To 10.0 Single Section
- Rotary Actuator Travel In Angular Deg [CQCK]
- 312.0 Nominal
- Screw Thread Diameter [AJYN]
- 0.250 Inches Nominal
- Screw Thread Quantity Per Inch [AJYQ]
- 32.0
- Screw Thread Series Designator [AJYP]
- Unef
- Section Quantity [AAPN]
- 1
- Shaft Diameter [ABWV]
- 0.250 Inches Nominal
- Shaft Style [AEDX]
- Round, Slotted
- Shaft Length [ABXF]
- 0.625 Inches Nominal
- Terminal Location [APXH]
- Radially Positioned Over Less Than Half The Circumference
- Terminal Type And Quantity [TTQY]
- 3 Tab, Solder Lug
Similar Supply Items to 5905-00-023-4837


















Freight Information 5905-00-023-4837
5905-00-023-4837 has freight characteristics.. 5905-00-023-4837 has a variance between NMFC and UFC when transported by rail and the description should be consulted.
Packaging Data 5905-00-023-4837
- Responsible Activity
- Packaging Data Source
- Primary Inventory Control Activity (PICA)
- --
Item Pack Level (Unpackaged)
- Item Size
- Item Weight
- Characteristics
- Weight/Dimensions Category
- Fragility
- Item Preservation
- Item Weight
- --
- --
- --
- 0.25 lb or less, one dimension 2" or less, other dimensions less than 24"
- 85 to 110G
- No Requirement
- --
Unit Pack Level (Packaged)
- Quantity per Pack
- Unit Size
- Unit Weight
- Unit Cube
- Preservation Method
- Cleaning/Drying
- Unit Size
- --
- --
- --
- --
- --
- No Requirements
- --
- Preservation Material
- Wrapping Material
- Cushioning/Dunnage
- Cushioning Thickness
- Container
- Special Marking
- Wrapping Material
- No Requirement
- A-A-1249, Paper, Tissue
- No Requirement
- Not Applicable
- --
- --
- A-A-1249, Paper, Tissue
Intermediate Pack Level
- Quantity of Unit Packs
- Container
- PPP-B-566 or PPP-B-676, Folding or Setup Box