5905-00-006-5548
Nonprecision Nonwire Wound Variable Resistor
5905000065548 000065548 960542-87 3292PG58-104
A resistor in which a sliding or rolling contact moves over an exposed area of the resistive element to change the ohmic value of the output. The functional tolerance (linearity), if given, of the output is greater than plus or minus 1 percent on linear outputs. Specified outputs such as sine, cosine, tangent, etc., shall be considered to be precision. For items having manually positioned taps designed to be set and fixed prior to use, see RESISTOR, ADJUSTABLE. For items with step by step variation, see RHEOSTAT and RESISTOR, STEP BY STEP. For tandem-mounted items designed to function together as an attenuator (and rated accordingly), see ATTENUATOR, VARIABLE. Excludes RESISTOR (1), VARIABLE, WIRE WOUND, NONPRECISION; RESISTOR (1), VARIABLE, NONWIRE WOUND PRECISION; and RESISTOR (1), VARIABLE, WIRE WOUND, PRECISION. View more Nonprecision Nonwire Wound Variable Resistor
November 2023
4

Marketplace 5905-00-006-5548
Request a Quotation from participating marketplace vendors
Related Documents 5905-00-006-5548 2+ Documents (More...)
United States (US) 4. 5905-00-006-5548 Marketplace Restrictions Approved Sources Datasheet Management
RQST NE Updated Every Day 5905-00-006-5548 RQST Updated Every Day 5905-00-006-5548 RQST NE Related
5905000065548 000065548,960542-87 Account Upgrade 5905-00-006-5548Nonprecision Nonwire Wound Variable
Resistor5905000065548 000065548 960542 ) https//www.nsnlookup.com /fsg-59/fsc-5905/us 5905-00-006-55485905000065548
Restrictions 5905-00-006-5548
5905-00-006-5548 is a Nonprecision Nonwire Wound Variable Resistor that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. The precious metals content of this item is unknown.
Approved Sources 5905-00-006-5548
- Part Number
- Manufacturer
- Status
- 960542-87
- Manufacturer
- 82577 - Raytheon Company (Active)
- Primary Buy
- Primary Buy
- 3292PG58-104
- 80294 - Bourns Instruments Inc (Obsolete)
- Secondary Buy
- Secondary Buy