Premium Information is available for this item - Upgrade for $1 a day
5895-01-328-2977
Signal Data Converter
5895013282977 013282977 LPVS-8
An electronic device which converts a data modulated signal of one form to a data modulated signal of another form. View more Signal Data Converter
January 2023
5
Marketplace 5895-01-328-2977
Request a Quotation from participating marketplace vendors
Related Documents 5895-01-328-2977 5+ Documents (More...)
Restrictions 5895-01-328-2977
5895-01-328-2977 is a Signal Data Converter that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. This item is a US Munitions List or Commerce Control List Item where key elements must be removed and destroyed to prevent this item being restored or repaired. Only authorized parties may possess this item. This item is not suspected to be hazardous. The precious metals content of this item is unknown.
Import and Export 5895-01-328-2977
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 5895-01-328-2977
- Canada (ZC01)
- Effective Date:
- 1 Apr 1991
Approved Sources 5895-01-328-2977
- Part Number
- Manufacturer
- Status
- LPVS-8
- Manufacturer
- 15422 - Timeplex Inc (Active)
- Primary Buy
- Primary Buy
Datasheet 5895-01-328-2977
- Characteristic
- Specifications
- FIIG
- Specifications
- A32200
- Average Power Rating Per Channel [BHTJ]
- 460.0 Watts Input
- Basic Shape Style [AGTA]
- Rectangular Or Square
- Frequency Per Channel [BHTB]
- 47.0 Hertz Minimum 8Th Input Channel And 63.0 Hertz Maximum 8Th Input Channel
- Signal Voltage Rating Per Channel [BHTK]
- 115.000 Volts Nominal Input
- Overall Height [ABKW]
- 17.000 Inches Nominal
- Overall Length [ABHP]
- 17.250 Inches Nominal
- Overall Width [ABMK]
- 12.250 Inches Nominal
- Phase [FAAZ]
- Single
NATO Stock Numbers Related to 5895-01-328-2977
Freight Information 5895-01-328-2977
5895-01-328-2977 has freight characteristics managed by Canada.. 5895-01-328-2977 has a variance between NMFC and UFC when transported by rail and the description should be consulted.