5130-00-596-1062

Electric Etcher

5130005961062 005961062 A-A-59252 50 MIL-E-3118 TY1 MIL-E-3118

A marking tool designed to form a permanent design on the surface of metal or other material by means of a vibrating point, or by means of an eletric arc. The electric arc type requires the grounding of the object being marked and may contain an integral demagnetizer. View more Electric Etcher

5130-00-596-1062 ETCHER,ELECTRIC 5130005961062 005961062

Managed by United States
NSN Created on 1 Jan 1963
Data Last Changed
August 2023
NATO Update Count
20
NATO Data Quality
5130-00-596-1062 ETCHER,ELECTRIC 5130005961062 005961062 1/1
NSN 5130-00-596-1062 (Generic Image) 1/1

5130-00-596-1062 Stock and Availability Marketplace 5130-00-596-1062

Need Help?
Request a Quotation from participating marketplace vendors

5130-00-596-1062 Related Documents Related Documents 5130-00-596-1062 5+ Documents (More...)

DAC: 5 19 Feb 1969 6240-17-705-0744 Glow Lamp GL4UITV1RNCC: 5 | RNVC: 2 | DAC: 5 5 Feb 1975 5130-00-596-1062
112-0640 5130-00-596-8404 5130-12-328-3600 5130-21-876-2723 5130-14-040-7564 5130-14-330-7524 5130-00-596-1062
: 4 27 Mar 1991 5130-01-335-1363 Electric Etcher GA236BRNCC: 3 | RNVC: 1 | DAC: 4 6 Mar 1991 5130-00-596-1062
Wheatland 6. 59252 N/S Corp is an Obsolete Manufacturer with the Cage Code 59252.
Lp Hampton Pump Service Frequently Asked Questions (FAQ) for CAGE 59252 What is CAGE Code 59252?
/S Corp located at , Wheatland PA 16161, United States.Who is CAGE Code 59252?
) Wheatland 6. 59252 N/S Corp is an Obsolete Manufacturer with the Cage Code 59252.
Lp Hampton Pump Service Frequently Asked Questions (FAQ) for CAGE 59252 What is CAGE Code 59252?
N/S Corp is an Obsolete Manufacturer with the Cage Code 59252.

5130-00-596-1062 Demil Restrictions 5130-00-596-1062

DEMIL: A | DEMILI: 1 | CRITICALITY: X | HMIC: N | PMIC: A | EDC: | ADPEC:

5130-00-596-1062 is a Electric Etcher that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. This item does not contain a precious metal.

5130-00-596-1062 HTS and ScheduleB Import and Export 5130-00-596-1062

5130-00-596-1062 End Users End Users 5130-00-596-1062

US Army (A192)
Effective Date:
1 Apr 1991
Supplementary Receivers:
AZCT
US Coast Guard (C014)
Effective Date:
1 Apr 1991
US Air Force (FGGS)
Effective Date:
1 Apr 1991
NASA (G721)
Effective Date:
1 Apr 1991
NASA (G751)
Effective Date:
1 Apr 1991
US Marine Corps (MC14)
Effective Date:
1 Apr 1991
US Navy (N9QG)
Effective Date:
1 Apr 1991
Supplementary Collaborators:
GTHD
Spain (YB01)
Effective Date:
1 Apr 1991
Germany (ZG01)
Effective Date:
1 Nov 2005
Republic of Korea (ZH01)
Effective Date:
1 Apr 1991
Portugal (ZP01)
Effective Date:
1 Apr 1991
Italy (ZR01)
Effective Date:
1 Jul 1997
Greece (ZU01)
Effective Date:
1 Apr 1991
Turkey (ZW01)
Effective Date:
1 Nov 2005

5130-00-596-1062 Manufacturers Approved Sources 5130-00-596-1062

5130-00-596-1062 Technical Data Datasheet 5130-00-596-1062

Characteristic
Specifications
FIIG
A571J0
Accessory Components And Quantity [AKYD]
Pencil Cord, Ground Cable, 3 Marking Points, And Case
Current Type [ACDC]
Ac
Design Type [APGF]
Electric Arc
Frequency Rating [ACZB]
60.0 Hertz Nominal
Phase [FAAZ]
Single
Special Features [FEAT]
5-1/2 X 7 In. Ground Plate; On Indicator Light
Voltage Rating [AMSE]
120.0 Volts Nominal
Wattage Rating In Watts [ASDK]
500.0 Nominal

5130-00-596-1062 Management Data Management Data 5130-00-596-1062

Effective Date
Organization
Unit of Issue
Unit Price
Qty Unit Pack
Jan 2023
Department of the Air Force (DF)
EA
Subscribe
1
Dec 2020
Department of the Navy (DN)
EA
Subscribe
1
Sep 2015
Department of the Air Force (DF)
EA
Subscribe
1

Army Army

Materiel Category and Inventory Manager:
E
General Supplies (DLA/GSA Items)
Appropriation and Budget Activity:
2
Stock Fund Secondary Items
Management Inventory Segment:
2
Non-Repairable Items(Exclusive of Insurance and Provisioning Items)
This code will be used to identify items, which are not reparable.
Weapons System / End Item / Homogeneous Group:
00
DLA/GSA Material
DLA/GSA-Managed Items that cannot be identified to a specific Army Weapons Systems/End Item
Accounting Requirements:
D
Durable item.An item of Army property coded with an ARC of D in the AMDF. Durable items do not require property book accountability after issue from the stock record account but do require hand receipt control when issued to the user. Commercial and fabricated items similar to items coded D in the AMDF are considered durable items.

Air Force Air Force

Fund:
SF
Stock fund applicable to items managed for the Air Force by the respective Inventory Control Point
Budget:
9
57X4921.070 - General Support DIV - Air Force decentralized managed expense items (ERRC XB3, XF3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors
Price Validation Code:
N
The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
The price has not been analyzed or reviewed for accuracy.
ZOP or Standard price challenges are permissible but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ā€œLā€ or ā€œFā€, then it must be evaluated locally where purchased or fabricated.
Expendability
Recoverability
Repairability:
U
Reparable. Condemn at Intermediate. AF Equipment Management System (AFEMS).

Navy Navy

Cognizance:
9Q

Marine Corps Marine Corps

Stores Account:
1
Stock Fund Account Item
Combat Essentiality:
2
Non-Critical Repair Part
Echelon Management:
02
Operational Test:
No Special Procedures

5130-00-596-1062 Related Items NATO Stock Numbers Related to 5130-00-596-1062

5130-00-596-1062 Freight Data Freight Information 5130-00-596-1062

5130-00-596-1062 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 186590. A Sub NMFC of X. It has a NMFC Description of TOOLS:ELEC HYDR PNEU/I/C ENG/PARTS. 5130-00-596-1062 is rated as class 85 when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 91790 which rates the freight between FCL and LCL. 5130-00-596-1062 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 732 for ocean manifesting and military sealift. 5130-00-596-1062 is not classified as a special type of cargo when transported by water. 5130-00-596-1062 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.