4920005058937 005058937 MJ3 NA5-3011D E2872

A cabinetlike item usually with a front work area and consisting of the necessary instrumentation, integral hydraulic system and component mounting facilities. Designed to provide the hydraulic pressure for testing and/or calibrating hydraulic system components, such as valves, actuating cylinders, pressure regulators, accumulators, hose lines, hand and/or engine driven pumps and the like. May include facilities for filling and checking hydraulic systems for leakage and performance. See also PUMPING UNIT, HYDRAULIC. View more Hydraulic System Components Test Stand

4920-00-505-8937 TEST STAND,HYDRAULIC SYSTEM COMPONENTS 4920005058937 005058937

Managed by United States
NSN Created on 1 Jan 1963
Data Last Changed
January 2023
NATO Update Count
11
NATO Data Quality
4920-00-505-8937 TEST STAND,HYDRAULIC SYSTEM COMPONENTS 4920005058937 005058937 1/1
NSN 4920-00-505-8937 (Generic Image) 1/1

4920-00-505-8937 Stock and Availability Marketplace 4920-00-505-8937

4920-00-505-8937 Related Documents Related Documents 4920-00-505-8937 5+ Documents (More...)

MJ3 NA5-3011D E2872 A cabinetlike item usually with a front work area and consisting of the necessary
MJ3 TEST STAND,HYDRAULIC SYSTEM COMPONENTS 2 EA NS Request Quotation Updated Every Day 4920-00-505-8937
Quotation E2872-11 TEST STAND,HYDRAULIC Hydraulic System Components Test Stand,MJ3 Upgrade 4920-00-505
your Account Upgrade 4920-00-600-1422Hydraulic System Components Test Stand4920006001422 006001422 MJ3
NA5-3011D E2872-11 A cabinetlike item usually with a front work area and consisting of the necessary
MJ3 TEST STAND,HYDRAULIC SYSTEM COMPONENTS 5 EA NS Request Quotation Subscribe to View Vendor Details
enable JavaScript in your web browser . 6615-14-303-0280Coffret Asservissem6615143030280 143030280 MJ3
https//www.nsnlookup.com /fsg-49/fsc-4920/us 4920-00-761-3234 Hydraulic System Components Test Stand,MJ3
enable JavaScript in your web browser . 6615-14-303 -0280Coffret Asservissem6615143030280 143030280 MJ3
enable JavaScript in your web browser . 3040-15-114-4709Manual Control Lever3040151144709 151144709 E2872
,MJ3 Upgrade 4920-00-505-8937Hydraulic System Components Test Stand4920005058937 005058937 MJ3 NA5-3011D
E2872 -11 TEST STAND,HYDRAULIC SYSTEM COMPONENTS 4 EA NS Request Quotation E2872-11 TEST STAND,HYDRAULIC
Hydraulic System Components Test Stand,MJ3 Account Upgrade 4920-00-505-8937Hydraulic System Components
Test Stand4920005058937 005058937 MJ3 NA5-3011D Stand4920005058937 005058937MJ3NA5-3011DE2872 NA5 https
https//www.nsnlookup.com /fsg-49/fsc-4920/us 4920-00-600-1422 Hydraulic System Components Test Stand,MJ3

4920-00-505-8937 Demil Restrictions 4920-00-505-8937

DEMIL: A | DEMILI: | CRITICALITY: X | HMIC: Y | PMIC: U | EDC: | ADPEC:

4920-00-505-8937 is a Hydraulic System Components Test Stand that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item has been determined to be hazardous and information is contained in the Hazardous Materials Information Resource System (HMIRS). The precious metals content of this item is unknown.

4920-00-505-8937 HTS and ScheduleB Import and Export 4920-00-505-8937

4920-00-505-8937 End Users End Users 4920-00-505-8937

Republic of Korea (ZH01)
Effective Date:
1 Apr 1991
Turkey (ZW01)
Effective Date:
1 Nov 2005

4920-00-505-8937 Manufacturers Approved Sources 4920-00-505-8937

4920-00-505-8937 Technical Data Datasheet 4920-00-505-8937

Characteristic
Specifications
FIIG
T361-E
Accumulator [AYJM]
Not Included
Engine Driven Hydraulic Pump Testing Design Feature [CGYK]
Not Included
Entry Date [NTRD]
90-02-28
Filtering System [CHGQ]
Included
Functional Classification [FCLS]
A-9.2
Functional Description [FTLD]
Used To Test Acft Hydraulic Systems And/Or Components Without Operating The Acft Engine Or Removing The Components
Horsepower Rating [ANCY]
175.0
Hydraulic Fluid Flow Rate [AAYJ]
20.0 Gallons Per Minute
Installation Design [AMQY]
Portable
Power Source [ATJK]
Gasoline Engine
Pressure Manifold Subcircuit [CGYM]
Not Included
Pressure Rating [BGST]
3000.0 Pounds Per Square Inch Nominal And 5000.0 Pounds Per Square Inch Nominal
Pressure/Suction Hose [CHGR]
Included
Reference Data And Literature [RDAL]
T.O.33A2-2-1-146
Special Features [FEAT]
Three Independent Systems
Usage Design [ALBY]
Aircraft Hydraulic System

4920-00-505-8937 Similar Items Similar Supply Items to 4920-00-505-8937

4920-00-505-8937 Freight Data Freight Information 4920-00-505-8937

4920-00-505-8937 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 147650. A Sub NMFC of X. It has a NMFC Description of OUTFITS MILITARY EQUIP FOR REPAIR. 4920-00-505-8937 is rated as class 77.5 when transported by Less-Than Truckload (LTL) freight. 4920-00-505-8937 is rated as class 100 when transported by Less-Than Carload (LCL) rail or ocean freight. It has a Uniform Freight Classification (UFC) number of 73790 which rates the freight between FCL and LCL. 4920-00-505-8937 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 657 for ocean manifesting and military sealift. 4920-00-505-8937 is not classified as a special type of cargo when transported by water. 4920-00-505-8937 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.

4920-00-505-8937 Packaging Data Packaging Data 4920-00-505-8937

Responsible Activity
Packaging Data Source
Primary Inventory Control Activity (PICA)
--

Item Pack Level (Unpackaged)

Item Size
Item Weight
Characteristics
Weight/Dimensions Category
Fragility
Item Preservation
--
--
--
--
--

Unit Pack Level (Packaged)

Quantity per Pack
Unit Size
Unit Weight
Unit Cube
Preservation Method
Cleaning/Drying
--
119.0" H x 60.0" W x 69.5" L
--
--
--
Any Suitable Process
Preservation Material
Wrapping Material
Cushioning/Dunnage
Cushioning Thickness
Container
Special Marking
Special Requirement
--
Cushion, Anchor, Block or Brace as Required
--
--
Special requirements

Intermediate Pack Level

Quantity of Unit Packs
Container
--
No Requirement