Premium Information is available for this item - Upgrade for $1 a day
4820-00-228-2314
Globe Valve
4820002282314 002282314 30-11NFC
A valve with one inlet and one outlet connection with outlet flow parallel to inlet flow. The flow is controlled by the action of a stem which lifts the disk perpendicularly off the center axis of its seat. The stem is at a 90 degree (1.5708 radians) angle to axis of flow. Excludes VALVE, STOP-CHECK; COCK, SHUTOFF, SCREW STEM; and VALVE, SOLENOID. View more Globe Valve
![]()
November 2023
5

Marketplace 4820-00-228-2314
Request a Quotation from participating marketplace vendors
Related Documents 4820-00-228-2314 1+ Documents (More...)
Globe Valve 4820002282314 002282314,30-11NFC Globe Valve 4820002282314 002282314,30-11NFC RQST NE Updated
Every Day 4820-00-228-2314 RQST Updated Every Day 4820-00-228-2314 RQST NE Related Documents 4820-00
Restrictions 4820-00-228-2314
4820-00-228-2314 is a Globe Valve that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. The precious metals content of this item is unknown.
End Users 4820-00-228-2314
- NASA (G900)
- Effective Date:
- 1 Apr 1991
Approved Sources 4820-00-228-2314
- Part Number
- Manufacturer
- Status
- 30-11NFC
- Manufacturer
- 07097 - Graco High Pressure Equipment Inc. (Active)
- Incomplete Reference
- Incomplete Reference
Datasheet 4820-00-228-2314
- Characteristic
- Specifications
- Bonnet Type [ADSR]
- Specifications
- Inside Screw
- Bonnet Attachment Method [ADST]
- Threaded
- Connection Style [AHNC]
- Plain,Optional End(Pipe) 1St End
- Connection Type [AWLS]
- Threaded Internal Pipe 1St End
- Face To Face Distance [CWCF]
- 2.000 Inches
- Features Provided [CBBL]
- Bonnet Packing
- Flow Control Device [ADQU]
- Needle
- Material [MATT]
- Steel Body
- Material [MATT]
- Steel Flow Control Device
- Maximum Operating Temp [AEHZ]
- 1000.0 Deg Fahrenheit Single Response
- Maximum Operating Pressure [CQGM]
- 30000.0 Pounds Per Square Inch Single Response
- Media For Which Designed [MEDA]
- Steam Single Response
- Nominal Pipe Size Accommodated [AAAR]
- 0.375 Inches 1St End
- Nominal Thread Size [CQJX]
- 0.375 Inches 1St End
- Offset Distance [ACJN]
- 0.375 Inches
- Material Document And Classification [MDCL]
- 66 Fed Std Single Material Response Body And Aisi 316/Sae 30316 Assn Std Single Material Response Body
- Material Document And Classification [MDCL]
- 66 Fed Std Single Material Response Flow Control Device And Aisi 316/Sae 30316 Assn Std Single Material Response Flow Control Device
- Valve Operation Method [AQLR]
- Manual
- Style Designator [STYL]
- Straight Thru W/Offset
- Thread Direction [AAJF]
- Right-Hand 1St End
- Thread Quantity Per Inch [CMLP]
- 18 1St End
- Thread Series Designator [THSD]
- Npt 1St End
Similar Supply Items to 4820-00-228-2314


















Freight Information 4820-00-228-2314
4820-00-228-2314 has freight characteristics.. 4820-00-228-2314 has a variance between NMFC and UFC when transported by rail and the description should be consulted.