Premium Information is available for this item - Upgrade for $1 a day
4520-00-585-2986
Gas Water Heater
4520005852986 005852986 ANSI Z21.10.1 A-A-2955 W-H-196 GPBTY4SZ40 W-H-196 AA29554R402986
A unit specifically designed for heating water by a direct fired method, utilizing a gas fuel burned in a combustion chamber inclosed within itself. May be incorporated with a tank as an integral or as a separate unit for storage of the water so heated. View more Gas Water Heater
January 2023
20
Marketplace 4520-00-585-2986
Request a Quotation from participating marketplace vendors
Related Documents 4520-00-585-2986 5+ Documents (More...)
N100-210C S100-210A A-A-2955 AA29554R1001865 W-H-196 GPBTY4SZ100 W-H-196 A unit specifically designed
4520005852986 005852986 Upgrade your Account Upgrade 4520-00-585-2986Gas Water Heater4520005852986 005852986
N100-210C S100-210A A-A-2955 AA29554R1001865 W-H-196 GPBTY4SZ100 W-H-196 A unit specifically designed
https//www.nsnlookup.com /fsg-45/fsc-4520/us 4520-00-585-2986 Gas Water Heater 4520005852986 005852986
N100-210C S100-210A A-A-2955 AA29554R1001865 W-H-196 GPBTY4SZ100 W-H-196 A unit specifically designed
https//www.nsnlookup.com /fsg-45/fsc-4520/us 4520-00-585-2986 Gas Water Heater 4520005852986 005852986
N100-210C S100-210A A-A-2955 AA29554R1001865 W-H-196 GPBTY4SZ100 W-H-196 A unit specifically designed
https//www.nsnlookup.com /fsg-45/fsc-4520/us 4520-00-585-2986 Gas Water Heater 4520005852986 005852986
-210A A-A-2955 AA29554R1001865 W-H-196 GPBTY4SZ100 W-H-196 A unit specifically designed https//www.nsnlookup.com
W-H-196 AA29554R300698 A-A-2955 A unit specifically designed for heating AA29554R1001865 W-H-196 GPBTY4SZ100
Restrictions 4520-00-585-2986
4520-00-585-2986 is a Gas Water Heater that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. This item does not contain a precious metal.
Import and Export 4520-00-585-2986
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 4520-00-585-2986
- NASA (G751)
- Effective Date:
- 1 Apr 1991
- US Navy (N9QG)
- Effective Date:
- 1 Jan 2014
- Supplementary Collaborators:
- GG
- United Kingdom (ZK01)
- Effective Date:
- 1 Aug 1999
Approved Sources 4520-00-585-2986
- Part Number
- Manufacturer
- Status
- ANSI Z21.10.1
- Manufacturer
- 80204 - American National Standards (Active)
- Incomplete Reference
- Incomplete Reference
- A-A-2955
- 58536 - Federal Commercial Item Description (Active)
- Canceled/Obsolete
- Canceled/Obsolete
- W-H-196 GPBTY4SZ40
- 80244 - General Services Administration (Active)
- Canceled/Obsolete
- Canceled/Obsolete
- W-H-196
- 81348 - Federal Specifications (Active)
- Canceled/Obsolete
- Canceled/Obsolete
- AA29554R402986
- 58536 - Federal Commercial Item Description (Active)
- Canceled/Obsolete
- Canceled/Obsolete
Datasheet 4520-00-585-2986
- Characteristic
- Specifications
- FIIG
- Specifications
- T285-B
- Furnished Items [AFJH]
- Pilot,Safety
- Gas Connection Thread Size And Series/Type Designator [AMNZ]
- 1/2-14 Npt
- Environmental Attribute Code [ENAC]
- Water Heaters, Gas, Residential - Energy Star-Heating And Cooling - Energy Efficient Products
- Flue Pipe Size [AMPA]
- 3.000 Inches Nominal
- Heating Capacity Per Hour [AMHR]
- 27.7 Gallons
- Material [MATT]
- Steel
- Maximum Operating Pressure [AAJJ]
- 127.5 Pounds Per Square Inch
- Mounting Position [ADSM]
- Vertical
- Operating Control Method [ALBM]
- Automatic
- Fsc Application Data [ZZZV]
- Residential Water Heater
- Inside Surface Treatment [AAJQ]
- Glass, Fused
- Insulated Feature [AHGR]
- Included
- Outside Surface Treatment [AAJP]
- Enameled
- Overall Diameter [ADAV]
- 21.000 Inches Maximum
- Overall Height [ABKW]
- 63.000 Inches Maximum
- Special Features [FEAT]
- Tank Capacity Can Be Plus Or Minus Two Gallons
- Water Inlet Connection Quantity [AMLQ]
- 1
- Water Inlet Connection Thread Size And Series/Type Designator [AMLL]
- 3/4-14 Npt
- Water Outlet Connection Quantity [AMLR]
- 1
- Water Outlet Connection Thread Size And Series/Type Designator [AMLM]
- 3/4-14 Npt
- Specific Gas For Which Designed [AENF]
- Natural Gas
- Tank Capacity [AMKA]
- 40.0 Gallons
Management Data 4520-00-585-2986
- Effective Date
- Organization
- Unit of Issue
- Unit Price
- Qty Unit Pack
- Unit of Issue
- Feb 2017
- Department of the Navy (DN)
- EA
- Subscribe
- EA
Navy
- Cognizance:
- 9Q
NATO Stock Numbers Related to 4520-00-585-2986
Freight Information 4520-00-585-2986
4520-00-585-2986 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 026520. A Sub NMFC of Z. It has a NMFC Description of HEATERS WATER. 4520-00-585-2986 is rated as a variable freight class when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 12650 which rates the freight between FCL and LCL. 4520-00-585-2986 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 736 for ocean manifesting and military sealift. 4520-00-585-2986 is not classified as a special type of cargo when transported by water. 4520-00-585-2986 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.