4410-01-505-0893
High Pressure Steam Boiler
4410015050893 015050893 ES18M
A closed metal vessel consisting of a drum(s) or shell and necessary tubes, fittings and direct connected end items. It is designed to convert water into steam by application of heat. Excludes low pressure boilers under 15 pounds (6.804 kg) per square inch (645.2 sq mm) gage steam pressure and evaporators. View more High Pressure Steam Boiler
May 2023
2

Marketplace 4410-01-505-0893
Request a Quotation from participating marketplace vendors
Related Documents 4410-01-505-0893 1+ Documents (More...)
Updated Every Day 4410-01-505-0893 RQST NE Related Documents 4410-01-505-0893 1+ Documents ( More...
) https//www.nsnlookup.com /fsg-44/fsc-4410/us 4410-01-505-0893 High Pressure Steam Boiler 4410015050893
Restrictions 4410-01-505-0893
4410-01-505-0893 is a High Pressure Steam Boiler that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. This item does not contain a precious metal.
End Users 4410-01-505-0893
- US Navy (N9BC)
- Effective Date:
- 1 May 2006
- Former MOE Rule:
- N9CD
- Supplementary Collaborators:
- HD
Approved Sources 4410-01-505-0893
- Part Number
- Manufacturer
- Status
- ES18M
- Manufacturer
- 90224 - Sussman-Automatic Corporation (Active)
- Primary Buy
- Primary Buy
Datasheet 4410-01-505-0893
- Characteristic
- Specifications
- FIIG
- Specifications
- T242-A
- Draft Type [ASND]
- Natural
- Current Type [ACDC]
- Dc
- Forced Circulation Feature [BLHY]
- Not Provided
- Frequency Rating [ACZB]
- 50.0 Hertz Minimum And 60.0 Hertz Maximum
- Horsepower Rating [ANCY]
- 1.8
- Ignition Method [BLJC]
- Electrical
- Maximum Operating Pressure [BJDW]
- 80.0 Pounds Per Square Inch Gage
- Mounting Method [AXGY]
- Floor
- Maintenance Parts [BLSH]
- Not Provided
- Marine Service Design Feature [BLSG]
- Not Provided
- Packaged Boiler [BLSK]
- Not Provided
- Special Features [FEAT]
- 6 Bolt Flanged Heating Element; 0.438 In. Mounting Hole In Each Leg Of Floor Mount; No Superheater; No Draft Type; No Packaged Boiler; No Igniter, The Boiler Is Electric Heated; 90 Psig Maximum Working Pressure, Although It Is Recommended At 80 - 83 Psig Max. Working Pressure; Relief Valve Set At 100 Psig; 22 Amps; 120 Volts Control Circuit; 480 Volts Power Circuit Voltage; 1.8 Boiler Horse Power
- Voltage Rating [AMSE]
- 480.0 Volts Nominal
- Waterwalls [BLHX]
- Not Provided
- Steam Capacity [BLHL]
- 36.000 Pounds Per Hour Minimum And 543.000 Pounds Per Hour Maximum
- Superheater [BLSL]
- Not Provided
DLA Procurement Analysis 4410-01-505-0893
Management Data 4410-01-505-0893
Navy
- Cognizance:
- 3B
Similar Supply Items to 4410-01-505-0893


















Freight Information 4410-01-505-0893
4410-01-505-0893 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 025770. A Sub NMFC of X. It has a NMFC Description of BOILER/HEATING/POWER C IRON HEAT EX. 4410-01-505-0893 is rated as class 65 when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 12210 which rates the freight between FCL and LCL. 4410-01-505-0893 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 713 for ocean manifesting and military sealift. 4410-01-505-0893 is not classified as a special type of cargo when transported by water. 4410-01-505-0893 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.
Packaging Data 4410-01-505-0893
- Responsible Activity
- Packaging Data Source
- Primary Inventory Control Activity (PICA)
- --
Item Pack Level (Unpackaged)
- Item Size
- Item Weight
- Characteristics
- Weight/Dimensions Category
- Fragility
- Item Preservation
- Item Weight
- --
- --
- Bare Metal Item
- Over 10lb
- Less than 85G
- No Requirement
- --
Unit Pack Level (Packaged)
- Quantity per Pack
- Unit Size
- Unit Weight
- Unit Cube
- Preservation Method
- Cleaning/Drying
- Unit Size
- 1
- --
- --
- --
- --
- Any Suitable Process
- --
- Preservation Material
- Wrapping Material
- Cushioning/Dunnage
- Cushioning Thickness
- Container
- Special Marking
- Wrapping Material
- No Requirement
- --
- --
- --
- Any Suitable Wood Crate
- No special marking
- --
Intermediate Pack Level
- Quantity of Unit Packs
- Container
- --
- No Requirement
Contracting Technical Data File (CTDF) 4410-01-505-0893 October 2021
Criticality and Quality
- Critical Item Code:
- Flight Safety:
- Life Support:
- Certified Samples:
- Serialization:
- First Article Test (FAT):
- Certificate of Quality Compliance:
- Production Lot Testing:
- Special Testing:
- Qualified Products List (QPL):
Commercial Properties
- Government Furnished Material:
- Government Furnished Tooling:
- Government Furnished Property:
- Price Evaluation Code:
- Diminshing Manufacturing Sources:
- Warranty:
- Commerical Off The Shelf (COTS):
- End Item Application:
- Auctioning Candidate:
- Source of Procurement:
- Contract Option:
Restrictions
- Boeing Rights Guard:
- Export Controlled:
- Controlled Technical Data Package (TDP):
- Restricted Technical Data Package (TDP):
- Contains Classified Material
- Weapons System Indicator Code (WSIC):
- N
Packaging Requirements
- Packaging Determination Table:
- Packaging Review Code:
- Special Packaging Instruction Number (SPIN):
- Special Packaging Instruction Number Revision:
- Special Packaging Instruction Number Date:
- Pallet Reference Number Required: