Industrial Boilers

Federal Supply Class (FSC): 4410

NATO Supply Classification Class (NSC): 4410

Group Description: Furnace, Steam Plant, and Drying Equipment; and Nuclear Reactors

Federal Supply Group (FSG): 44

NATO Supply Classification Group (NSG): 44

Page 5 of 38

NSN Format for Industrial Boilers

4410XXXXXXXXX
Group
FSG
ClassNCBIdentifier
FSC
Federal Supply Class
NIIN
NSN
FSC 4410 Industrial Boilers
FSC 4410 Industrial Boilers

Includes Steam Boilers, over 15 pounds WSP. Marine Boilers; Boiler Drums; Water Heaters, Low Pressure (over 100 gallon recovery capacity).

Additional Information for Industrial Boilers Additional Information for Industrial Boilers

NATO Supply Class 4410 refers to Industrial Boilers, which are categorized under NATO Supply Group 44. This supply group includes Furnace, Steam Plant, and Drying Equipment, as well as Nuclear Reactors.

Industrial boilers are large vessels that are designed to generate steam or heat water for industrial processes or heating purposes. They are commonly used in various industries such as power generation, manufacturing, and chemical processing.

NATO Supply Class 4410 specifically focuses on the classification and categorization of industrial boilers within the broader supply group. This classification system helps in standardizing the identification and procurement of specific equipment within NATO member countries.

By categorizing industrial boilers under NATO Supply Class 4410, it becomes easier for NATO member countries to communicate and coordinate their procurement efforts. This classification system ensures that the right equipment is acquired and used for specific purposes, promoting interoperability and efficiency among NATO forces.

It is important to note that NATO Supply Class 4410 is just one of the many supply classes and groups within the NATO Supply Classification System (NSCS). The NSCS is a comprehensive system that covers a wide range of equipment and supplies used by NATO forces, facilitating effective logistics and supply chain management.

If you require more specific information about industrial boilers or any other aspect of the NATO Supply Classification System, please let me know.

NSN by Country NSN by Country

Frequently Asked Questions(FAQ) for Federal Supply Class 4410 Frequently Asked Questions(FAQ) for Federal Supply Class 4410

What is Federal Supply Class 4410?
FSC 4410 is the Federal Supply Class(formally known as NATO Supply Classification Class NSC 4410) in the USA for supply items codified in the category of Industrial Boilers.
What is NATO Supply Classification Class 4410?
NSC 4410 is the NATO Supply Classification Class (also known as Federal Supply Class FSC 4410 in the USA) for supply items codified in the category of Industrial Boilers.
Which Federal Supply Group is FSC 4410 in?
FSC 4410 is in Federal Supply Group(FSG) 44 which contains .
Which NATO Supply Classification Group is NSC 4410 in?
NSC 4410 is in NATO Supply Classification Group(NSG) 44 which contains .

Supply Items Included in Federal Supply Class 4410 Supply Items Included in Federal Supply Class 4410

What is a Soot Blower Head? 30 Items
A Soot Blower Head (HEAD,SOOT BLOWER) is a mechanical device for the simultaneous control of the rotation and the admission of air or steam into a soot blower element.
What is a High Pressure Steam Boiler? 222 Items
A High Pressure Steam Boiler (BOILER,STEAM,HIGH PRESSURE) is a closed metal vessel consisting of a drum(s) or shell and necessary tubes, fittings and direct connected end items. It is designed to convert water into steam by application of heat. Excludes low pressure boilers under 15 pounds (6.804 kg) per square inch (645.2 sq mm) gage steam pressure and evaporators.
What is an Electric Water Heater? 178 Items
An Electric Water Heater (HEATER,WATER,ELECTRIC) is a unit specifically designed for heating water by a direct fired method, utilizing electric heating element(s).
What is a Gas Water Heater? 12 Items
A Gas Water Heater (HEATER,WATER,GAS) is a unit specifically designed for heating water by a direct fired method, utilizing a gas fuel burned in a combustion chamber inclosed within itself. May be incorporated with a tank as an integral or as a separate unit for storage of the water so heated.
What is a Feed Water Regulating Valve? 41 Items
A Feed Water Regulating Valve (VALVE,REGULATING,FEED WATER) is a valve designed for regulating feed water flow to boilers. It is not a self-contained control but a component of boiler feed water regulating system.
What is a Steam Boiler System Surge Tank? 15 Items
A Steam Boiler System Surge Tank (TANK,SURGE,STEAM BOILER SYSTEM) is an auxiliary container for steam boiler feed water, which also has the function of collecting returned condensate. It has a compensating, or stabilizing effect when the demand for boiler make-up water may exceed the rate at which water is being returned from the heating system, or when the water may be returning at a rate which is greater than the requirements of the boiler.
What is a Soot Blower Element? 228 Items
A Soot Blower Element is an item designed to distribute steam and/or air inside a boiler, for the purpose of cleaning tubes and walls.
What is an Immersion Type Electrical Heating Element? 611 Items
An Immersion Type Electrical Heating Element (HEATING ELEMENT,ELECTRICAL,IMMERSION TYPE) is an electrical device in the form of a resistor consisting of a resistance wire, an insulating material, and a sheath. It is designed to transform electrical current into heat while immersed in a liquid to be heated or in contact with materials to be melted. It may include an automatic control to regulate the amount of heat generated.
What is a Steam-Hot Water Heated Water Heater? 40 Items
A Steam-Hot Water Heated Water Heater (HEATER,WATER,STEAM-HOT WATER HEATED) is a unit designed to heat water in a storage tank which is equipped with a coil that receives steam or hot water from another source. See also HEATER, FLUID, INDUSTRIAL.
What is a Boiler Feed Water Pump And Burner Controller? 18 Items
A Boiler Feed Water Pump And Burner Controller (CONTROLLER,FEED WATER PUMP AND BURNER,BOILER) is an item designed to maintain the predetermined safe water level in automatically fired boilers and to interrupt the circuit to the burner in the event of failure of the water supply. The boiler water level is reproduced, by equalizing lines, in a float chamber and the pump and burner switches are actuated by a float mechanism. Excludes CONTROL, COMBUSTION, OIL BURNER and FEEDER, BOILER WATER.
What is a Boiler Water Feeder? 16 Items
A Boiler Water Feeder (FEEDER,BOILER WATER) is an item designed to maintain the predetermined safe water level in a boiler. The boiler water level is reproduced, by equalizing lines, in a float chamber and an integrally mounted float operated valve automatically admits water to the boiler as required. Excludes CONTROLLER, FEED WATER PUMP AND BURNER, BOILER and items not self-contained such as VALVE, REGULATING, FEED WATER.
What is a Steam And Electric Heated Water Heater? 24 Items
A Steam And Electric Heated Water Heater (HEATER,WATER,STEAM AND ELECTRIC HEATED) is a unit specifically designed to heat water in a storage tank by means of a coil that receives steam from another source, and, in addition is equipped with auxiliary electric heating element(s).
What is an Oil Burner Atomizer Sprayer Plate? 28 Items
An Oil Burner Atomizer Sprayer Plate (PLATE,SPRAYER,OIL BURNER ATOMIZER) is a part of an oil burner atomizer which transforms the solid streams of oil under high pressure into a cone of foglike particles.
What is a Liquid Fuel Water Heater? 56 Items
A Liquid Fuel Water Heater (HEATER,WATER,LIQUID FUEL) is an item designed for heating water by a direct-fired method, using a liquid fuel burned in a combustion chamber inclosed within itself. It may be capable of using more than one type of fuel, such as gasoline, oil, kerosine, or jet fuel. It may be incorporated with a tank as an integral or as a separate unit for storage of the water so heated. For items that use liquefied petroleum gas, see HEATER, WATER, GAS. Excludes sidearm heaters.
What is an Electric Fluid Heater? 113 Items
An Electric Fluid Heater (HEATER,FLUID,ELECTRIC) is a unit specifically designed for heating fluid by a direct fired method, utilizing electric heating element.
What is a Boiler Tube? 745 Items
A Boiler Tube is a tubular item, usually pre-bent forming part of the heating surface area of a high pressure steam boiler.
What is a Gage And Valve Assembly? 13 Items
A Gage And Valve Assembly is an assembly of items consisting of one or more gages and one or more valves joined together on a common mount.
What is a Boiler Control Panel? 28 Items
A Boiler Control Panel (PANEL,BOILER CONTROL) is a panel, upon which are mounted relays, switches, transformers and the like, which are specifically designed for the purpose of controlling the operation of an industrial boiler.
Parts Kit,High Pressure Steam Boiler 43 Items

Stock Items From Supply Class 4410 Stock Items From Supply Class 4410 Page 5of 38

005205878
658905056
RNCC: 3 | RNVC: 2
005205877
658905757
RNCC: 3 | RNVC: 2
005205879
658905058
RNCC: 3 | RNVC: 2
005200144
658905012
RNCC: 3 | RNVC: 2
005117304
C314PC22-41A41B54-62T067-76T07
RNCC: 3 | RNVC: 2
005117303
MC120-5PC8-22-41A41B49-54-57-6
RNCC: 3 | RNVC: 2
005117300
X1826G2DH2
RNCC: 3 | RNVC: 2
X1826G2PCDH2
RNCC: 3 | RNVC: 2
005062630
1JH5078P19
RNCC: 3 | RNVC: 2
1JA9356
RNCC: 3 | RNVC: 2
1JH5078PC19
RNCC: 3 | RNVC: 2
905J196P15
RNCC: 5 | RNVC: 1
1JH598PC23
RNCC: 5 | RNVC: 2
905J196P15
RNCC: 5 | RNVC: 9
004727380
955-596-97B29
RNCC: 3 | RNVC: 2
RR-F-191
RNCC: 4 | RNVC: 1
955-596-97CPC29
RNCC: 5 | RNVC: 2
955-596-97-29
RNCC: 5 | RNVC: 2
955-596-97BPC29
RNCC: 5 | RNVC: 2
M745-179PC29
RNCC: 5 | RNVC: 2
955-596-97CP29
RNCC: D | RNVC: 9
004699786
WG450
RNCC: 3 | RNVC: 2
004635101
310940001-32465-52468
RNCC: 3 | RNVC: 2
38384
RNCC: 5 | RNVC: 9
004426881
A12445
RNCC: 3 | RNVC: 2
397M2
RNCC: 5 | RNVC: 9
004169543
MB6L
RNCC: 3 | RNVC: 2
003960934
NY390-277-2-115
RNCC: 3 | RNVC: 2
D301-987B
RNCC: 5 | RNVC: 2
NY441-113PCS13
RNCC: 5 | RNVC: 2
NY441-113S13
RNCC: 5 | RNVC: 2
NY540-147REVGPC115
RNCC: 5 | RNVC: 2
3251409REVGPC115
RNCC: 5 | RNVC: 2
003953036
30AW4-25
RNCC: 3 | RNVC: 2
30AW4-25
RNCC: 3 | RNVC: 2
B788-494-30B
RNCC: 5 | RNVC: 2
003934540
17043
RNCC: 3 | RNVC: 2
V3132
RNCC: 3 | RNVC: 2
10621-2PCV3132
RNCC: 3 | RNVC: 2
11653-5PCV3132
RNCC: 3 | RNVC: 2
003886778
MX271716PC690AND696
RNCC: 3 | RNVC: 2
003886774
MX260888-693X697
RNCC: 3 | RNVC: 2
MX260888PC693-697
RNCC: 3 | RNVC: 2
MX260889PC693-697
RNCC: 3 | RNVC: 2
003886766
MX262825-737X739
RNCC: 3 | RNVC: 2
MX262825PC737-739
RNCC: 3 | RNVC: 2
003859357
MX243972PCLCXR
RNCC: 3 | RNVC: 2
MX260044LCXR
RNCC: 3 | RNVC: 2
MX260126-10PCLCXR
RNCC: 3 | RNVC: 2
MX243714PCLCXR
RNCC: 3 | RNVC: 2
003859354
MX260044LCZL
RNCC: 3 | RNVC: 2
MX260126-10PCLCZL
RNCC: 3 | RNVC: 2
MX260044LCZL
RNCC: 5 | RNVC: 9
MX260126-10PCLCZL
RNCC: 5 | RNVC: 9
003782543
37-101A
RNCC: 3 | RNVC: 2
003782534
5M27929A
RNCC: 3 | RNVC: 9
003782533
5M27660A
RNCC: 3 | RNVC: 9
003782524
S5101-3122448MARK4
RNCC: 3 | RNVC: 2
D-422-69
RNCC: 5 | RNVC: 1
003782530
3M27666C
RNCC: 3 | RNVC: 9
003782528
3M27666A
RNCC: 3 | RNVC: 9
003782527
5ME45231PT3ME37861
RNCC: 3 | RNVC: 9
003782529
3M27666B
RNCC: 3 | RNVC: 9
003782526
5ME45244PT3ME28980
RNCC: 3 | RNVC: 9
003779933
535192D1
RNCC: 3 | RNVC: 2
535192D1
RNCC: 3 | RNVC: 2
G535192D1
RNCC: 5 | RNVC: 2
G535192D1
RNCC: 5 | RNVC: 9
003779927
58877A1
RNCC: 3 | RNVC: 2
58877A1
RNCC: 5 | RNVC: 9
003779928
192179H2
RNCC: 3 | RNVC: 2
192179H2
RNCC: 5 | RNVC: 9
003779902
581030A4
RNCC: 3 | RNVC: 2
581030A4
RNCC: 5 | RNVC: 9
003779911
532238A4
RNCC: 3 | RNVC: 2
532238A4
RNCC: 5 | RNVC: 9
003779906
535745A1
RNCC: 3 | RNVC: 2
535745A1
RNCC: 5 | RNVC: 9