Premium Information is available for this item - Upgrade for $1 a day
4320-01-258-8372
Bulk Transfer Flammable Liquid Pumping Assembly
4320012588372 012588372 D-9044
A transportable unit consisting of a pump, prime mover, and necessary accessories and attachments, designed for transferring liquid petroleum products from or to underground bulk tanks, above ground bulk tanks, railroad tank cars or military tank trucks, and to vehicular tanks or individual containers. Excludes PUMP, CENTRIFUGAL; PUMP, RECIPROCATING, DIRECT ACTING; PUMP, RECIPROCATING; and PUMP, ROTARY. View more Bulk Transfer Flammable Liquid Pumping Assembly
January 2023
4

Marketplace 4320-01-258-8372
Request a Quotation from participating marketplace vendors
Related Documents 4320-01-258-8372 2+ Documents (More...)
,D-9044 United States (US) 4. 4320-01-258-8372 Marketplace Restrictions Approved Sources Datasheet Management
RQST NE Updated Every Day 4320-01-258-8372 RQST Updated Every Day 4320-01-258-8372 RQST NE Related Documents
4320012588372 012588372,D-9044 Every Day 4320-01-258-8372 RQST NE Restrictions https//www.nsnlookup.com
CharacteristicSpecificationsFIIGA514B0End Item Identification [AGAV] 4320-00-131-9185 https//www.nsnlookup.com /fsg-43/fsc-4320/us 4320-01-258-8372
Restrictions 4320-01-258-8372
IUID Required
4320-01-258-8372 is a Bulk Transfer Flammable Liquid Pumping Assembly that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. This item does not contain a precious metal.
Import and Export 4320-01-258-8372
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 4320-01-258-8372
- US Air Force (FGG4)
- Effective Date:
- 1 Apr 1991
- US Navy (NQGS)
- Effective Date:
- 1 Oct 2014
Approved Sources 4320-01-258-8372
- Part Number
- Manufacturer
- Status
- D-9044
- Manufacturer
- 62503 - Buffaloes Fire Pump Inc. (Active)
- Primary Buy
- Primary Buy
Datasheet 4320-01-258-8372
- Characteristic
- Specifications
- FIIG
- Specifications
- T103-M
- Drum Emptying Manifold Assembly [AYJE]
- Not Included
- Cable Reel [AYJB]
- Not Included
- Capacity Rating [ATYX]
- 600.0 Gallons Per Minute
- Discharge Connection Type [ASHJ]
- Quick Disconnect
- Explosion Proof Feature [AYHM]
- Included
- Ground Cable [AYJA]
- Included
- Hose Reel Quantity [AYHX]
- 1
- Mounting Type [AAXX]
- Trailer
- Pump Type [AXEL]
- Centrifugal
- Prime Mover Type [AKDJ]
- Diesel Engine
- Special Features [FEAT]
- Designed For 6 In. Hose,4 In. Gate Valve; Water-Cooled,Covered Engine; Cover Encases Heater To Pre-Heat Engine To Oper Temp Of -20 Deg F To -40 Deg F ; Lifting Frame & Tie Down Provisions Incl; Mb1 Trailer; Self Priming Pump; L 118 In.; W 68 In.; H 74 In.
- Specification/Standard Data [ZZZK]
- 81349-Mil-P-38447 Government Specification
- Suction Connection Type [AWZD]
- Quick Disconnect
Management Data 4320-01-258-8372
- Effective Date
- Organization
- Unit of Issue
- Unit Price
- Qty Unit Pack
- Unit of Issue
- Dec 2008
- Department of the Air Force (DF)
- EA
- Subscribe
- 1
- EA
- MOE
- USC
- Code
- Statement
- Order of Use
- Jump To Code
- Qty Per Assy
- UOM
- Technical Document
- Quantative Expression
- Code
- Department of the Air Force (DF)
- L
- E
- Replaced By 4320-00-131-9185
- E
Air Force
- Budget:
- M
- 57X3080 - Other Base Maintenance and Support Equipment
- Aggregation Code:
- RN
- GROUND SUPPORT EQUIPMENT (FSC RESIDUAL MMAC)
- Price Validation Code:
- E
- The current standard price is an estimated price.
Estimated Price challenges are allowed but follow procedures in para 60.b. (3) of section L of this manual.
This code will be changed to a P code upon notification of a contract price or this code will be changed to an updated code upon determination of a valid price.
- Expendability
Recoverability
Repairability: - U
- Reparable. Condemn at Intermediate. AF Equipment Management System (AFEMS).
NATO Stock Numbers Related to 4320-01-258-8372
Freight Information 4320-01-258-8372
4320-01-258-8372 has freight characteristics managed by the General Services Administration (GSA).It has a National Motor Freight Classification (NMFC) of 128000. A Sub NMFC of X. It has a NMFC Description of PUMPS PWR NOI/WORKING HEADS/PARTS. 4320-01-258-8372 is rated as class 85 when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 64870 which rates the freight between FCL and LCL. 4320-01-258-8372 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 743 for ocean manifesting and military sealift. 4320-01-258-8372 is not classified as a special type of cargo when transported by water. 4320-01-258-8372 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.
Packaging Data 4320-01-258-8372
- Responsible Activity
- Packaging Data Source
- Primary Inventory Control Activity (PICA)
- --
Item Pack Level (Unpackaged)
- Item Size
- Item Weight
- Characteristics
- Weight/Dimensions Category
- Fragility
- Item Preservation
- Item Weight
- --
- --
- --
- --
- --
- --
Unit Pack Level (Packaged)
- Quantity per Pack
- Unit Size
- Unit Weight
- Unit Cube
- Preservation Method
- Cleaning/Drying
- Unit Size
- 1
- 105.0" H x 67.0" W x 76.0" L
- --
- --
- --
- Any Suitable Process
- 105.0" H x 67.0" W x 76.0" L
- Preservation Material
- Wrapping Material
- Cushioning/Dunnage
- Cushioning Thickness
- Container
- Special Marking
- Wrapping Material
- Special Requirement
- Special Requirements – see Specific Instructions or Drawings provided
- Special Requirements. See Specific Instructions or Drawings Provided
- Special Requirements. See Specific Instructions or Drawings Provided
- Special requirement – See specific instructions or drawings provided
- Special requirements
- Special Requirements – see Specific Instructions or Drawings provided
Intermediate Pack Level
- Quantity of Unit Packs
- Container
- No Requirement