Premium Information is available for this item - Upgrade for $1 a day
4320-00-528-3555
Rotary Pump Unit
4320005283555 005283555 BXUS2STYLETB
An assembled unit consisting of a commonly mounted rotary pump(s), prime mover(s), and the necessary components to provide for a complete operation. View more Rotary Pump Unit
November 2023
5

Marketplace 4320-00-528-3555
Request a Quotation from participating marketplace vendors
Related Documents 4320-00-528-3555 1+ Documents (More...)
United States (US) 4. 4320-00-528-3555 Marketplace Restrictions Approved Sources Datasheet Management
RQST NE Updated Every Day 4320-00-528-3555 RQST Updated Every Day 4320-00-528-3555 RQST NE Related Documents
Restrictions 4320-00-528-3555
4320-00-528-3555 is a Rotary Pump Unit that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. This item does not contain a precious metal.
End Users 4320-00-528-3555
- US Air Force (FGG4)
- Effective Date:
- 1 Apr 1991
Approved Sources 4320-00-528-3555
- Part Number
- Manufacturer
- Status
- BXUS2STYLETB
- Manufacturer
- 07524 - Dover Pumps & Process Solutions (Active)
- Incomplete Reference
- Incomplete Reference
Datasheet 4320-00-528-3555
- Characteristic
- Specifications
- Cooling Method [AENK]
- Specifications
- Air To Air Cooled
- Current Type [ACDC]
- Ac
- Discharge Connection Quantity [AAYV]
- 1
- Discharge Connection Thread Size And Series/Type Designator [ASAZ]
- 2.000-11-1/2 Nh
- Discharge Connection Type [AAYW]
- Threaded Internal
- Discharge Pressure [AHYW]
- 50.0 Pounds Per Square Inch Gage
- Environmental Protection [ADZC]
- Dust-Ignition Proof
- Frequency In Hertz [FREQ]
- 60.0
- Maximum Discharge Flow Rate [AHYV]
- 60.0 Gallons Per Minute
- Mounting Type [AAXX]
- Trailer
- Operating Speed At Rated Capacity [AHYZ]
- 500.0 Revolutions Per Minute
- Inclosure Type [AKNA]
- Fully Inclosed
- Intake Connection Quantity [AAYT]
- 1
- Intake Connection Thread Size And Series/Type Designator [ASWT]
- 2.000-11-1/2 Nh
- Intake Connection Type [AAYU]
- Threaded Internal
- Prime Mover Cooling Medium [AAXS]
- Air
- Prime Mover Power Rating [CSYL]
- 2.000 Horsepower
- Prime Mover Quantity [AAXH]
- 1
- Prime Mover Type [AKDJ]
- Electric Motor
- Pump Quantity [AENC]
- 1
- Pumping Element Operating Position [AHZA]
- Vertical
- Reference Number Differentiating Characteristics [ZZZY]
- As Modified By Trailer Mounted
- Rotary Pump Design [AHZR]
- Vane
- Phase [FAAZ]
- Three
- Total Head [AHYX]
- 20.000 Feet
- Voltage In Volts [ELEC]
- 220.0 And 440.0
Management Data 4320-00-528-3555
- Effective Date
- Organization
- Unit of Issue
- Unit Price
- Qty Unit Pack
- Unit of Issue
- Dec 2016
- Department of the Air Force (DF)
- EA
- Subscribe
- 1
- EA
- MOE
- USC
- Code
- Statement
- Order of Use
- Jump To Code
- Qty Per Assy
- UOM
- Technical Document
- Quantative Expression
- Code
- Department of the Air Force (DF)
- L
- N
- Disposal
- N
Air Force
- Budget:
- Y
- Centrally procured equipment items. They are separate, primary end items (other than the weapon system itself) needed by a user to perform an assigned mission. They are non-expendable items (ERRC NF or ND) which are not consumed in use, and they do not lose their original identity during periods of use by incorporation into, or attachment to another assembly
- Price Validation Code:
- N
- The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
The price has not been analyzed or reviewed for accuracy.
ZOP or Standard price challenges are permissible but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of “L” or “F”, then it must be evaluated locally where purchased or fabricated.
- Expendability
Recoverability
Repairability: - U
- Reparable. Condemn at Intermediate. AF Equipment Management System (AFEMS).
NATO Stock Numbers Related to 4320-00-528-3555
Freight Information 4320-00-528-3555
4320-00-528-3555 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 128000. A Sub NMFC of X. It has a NMFC Description of PUMPS PWR NOI/WORKING HEADS/PARTS. 4320-00-528-3555 is rated as class 85 when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 64870 which rates the freight between FCL and LCL. 4320-00-528-3555 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 72D for ocean manifesting and military sealift. 4320-00-528-3555 is not classified as a special type of cargo when transported by water. 4320-00-528-3555 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.
Packaging Data 4320-00-528-3555
- Responsible Activity
- Packaging Data Source
- Primary Inventory Control Activity (PICA)
- --
Item Pack Level (Unpackaged)
- Item Size
- Item Weight
- Characteristics
- Weight/Dimensions Category
- Fragility
- Item Preservation
- Item Weight
- --
- --
- --
- --
- --
- --
Unit Pack Level (Packaged)
- Quantity per Pack
- Unit Size
- Unit Weight
- Unit Cube
- Preservation Method
- Cleaning/Drying
- Unit Size
- 1
- 110.0" H x 59.5" W x 42.5" L
- --
- --
- --
- Any Suitable Process
- 110.0" H x 59.5" W x 42.5" L
- Preservation Material
- Wrapping Material
- Cushioning/Dunnage
- Cushioning Thickness
- Container
- Special Marking
- Wrapping Material
- Special Requirement
- Special Requirements – see Specific Instructions or Drawings provided
- Special Requirements. See Specific Instructions or Drawings Provided
- Special Requirements. See Specific Instructions or Drawings Provided
- Special requirement – See specific instructions or drawings provided
- Special requirements
- Special Requirements – see Specific Instructions or Drawings provided
Intermediate Pack Level
- Quantity of Unit Packs
- Container
- --
- No Requirement