Premium Information is available for this item - Upgrade for $1 a day
4140-01-132-4527
Tubeaxial Fan
4140011324527 011324527 PROPIMAX2 395JH PR0PIMAX 2 395J 033218 808254-4
A nonpositive displacement mechanical device without guide vanes and having an axial fan impeller inclosed within a tubular housing. It is designed primarily for duct installation to move air or gas axially over a wide range of volumes at medium pressures. View more Tubeaxial Fan
May 2023
7
Marketplace 4140-01-132-4527
Request a Quotation from participating marketplace vendors
Related Documents 4140-01-132-4527 5+ Documents (More...)
Tubeaxial Fan 4140011324527 011324527 fsg-41/fsc-4140/us 4140-00-913-6072 Tubeaxial Fan 4140009136072
/fsg-41/fsc-4140/us
-0001 95542 - Northrop Grumman Systems Corporation (Active) Secondary Buy RNCC 5 RNVC 2 DAC 2 PROPIMAX2-395JH
NumberManufacturerStatus023388 82877 - Rotron Incorporated (Active) Primary Buy RNCC 3 RNVC 2 DAC 5 PROPIMAX2-395JH
Restrictions 4140-01-132-4527
4140-01-132-4527 is a Tubeaxial Fan that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. This item does not contain a precious metal.
Import and Export 4140-01-132-4527
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 4140-01-132-4527
- US Navy (N9BZ)
- Effective Date:
- 1 Sep 2006
- Former MOE Rule:
- N9ZD
- Supplementary Collaborators:
- KE
- Canada (ZC01)
- Effective Date:
- 1 Apr 1991
- Republic of Korea (ZH01)
- Effective Date:
- 1 Nov 1994
Approved Sources 4140-01-132-4527
- Part Number
- Manufacturer
- Status
- 033218
- Manufacturer
- 82877 - Rotron Incorporated (Active)
- Primary Buy
- Primary Buy
- PROPIMAX2 395JH
- 82877 - Rotron Incorporated (Active)
- Incomplete Secondary Reference
- Incomplete Secondary Reference
- 808254-4
- 96214 - Raytheon Company (Active)
- Secondary Buy
- Secondary Buy
- PR0PIMAX 2 395J
- 82877 - Rotron Incorporated (Active)
- Advisory Reference
- Advisory Reference
Datasheet 4140-01-132-4527
- Characteristic
- Specifications
- FIIG
- Specifications
- A087A0
- Drive Type [AKCV]
- Direct
- Electrical Connection Type [AGBD]
- Terminal Block
- Air Flow Rate [CQKX]
- 66.0 Cubic Feet Per Minute Nominal
- Ambient Temp At Full Rated Power [AEHY]
- 100.0 Deg Celsius
- Environmental Protection [ADZC]
- Dustproof And Explosion Proof And Fungus Resistant And Humidity Proof And Salt Spray Resistant And Shock Proof And Vibration Proof
- Flow Direction [ADNK]
- Outward
- Frequency In Hertz [FREQ]
- 400.0
- Housing Inside Diameter [CWLX]
- 3.054 Inches Minimum And 3.074 Inches Maximum
- Material Document And Classification [MDCL]
- Qq-A-591 Fed Spec Single Material Response Overall
- Material [MATT]
- Aluminum Alloy Overall
- Operating Speed At Rated Capacity In Rpm [AEQC]
- 12200.0
- Inclosure Type [AKNA]
- Fully Inclosed
- Length [ABRY]
- 1.516 Inches Minimum And 1.636 Inches Maximum
- Prime Mover Drive Shaft Bearing Type [CWLY]
- Ball
- Prime Mover Type [AKDJ]
- Electric Motor
- Rotation Direction For Which Designed [AYSY]
- Clockwise
- Phase [FAAZ]
- Three
- Special Features [FEAT]
- Gray Enamel Finish
- Voltage In Volts And Current Type [CSBH]
- 200.0 Ac
- Speed Adjustments [ABBB]
- Single Speed
- Static Pressure At Specified Air Flow Rate [AJLY]
- 0.92 Inches Of Water
- Style Designator [STYL]
- Fixed
- Surface Treatment Document And Classification [STDC]
- Fed Std 595 Fed Std Single Treatment Response Overall
- Surface Treatment [SFTT]
- Enamel Overall
Weapon Systems (WSDC) 4140-01-132-4527
DLA Procurement Analysis 4140-01-132-4527
Management Data 4140-01-132-4527
Navy
- Cognizance:
- 9B
- Navy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
NATO Stock Numbers Related to 4140-01-132-4527
Freight Information 4140-01-132-4527
4140-01-132-4527 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 061920. A Sub NMFC of X. It has a NMFC Description of FANS ELEC NOI IN BARREL/BOX/CRATE. 4140-01-132-4527 is rated as class 100 when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 34690 which rates the freight between FCL and LCL. 4140-01-132-4527 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 752 for ocean manifesting and military sealift. 4140-01-132-4527 is not classified as a special type of cargo when transported by water. 4140-01-132-4527 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.
Contracting Technical Data File (CTDF) 4140-01-132-4527 October 2021
Criticality and Quality
- Critical Item Code:
- Flight Safety:
- Life Support:
- Certified Samples:
- Serialization:
- First Article Test (FAT):
- Certificate of Quality Compliance:
- Production Lot Testing:
- Special Testing:
- Qualified Products List (QPL):
Commercial Properties
- Government Furnished Material:
- Government Furnished Tooling:
- Government Furnished Property:
- Price Evaluation Code:
- Diminshing Manufacturing Sources:
- Warranty:
- Commerical Off The Shelf (COTS):
- End Item Application:
- Auctioning Candidate:
- Source of Procurement:
- Contract Option:
Restrictions
- Boeing Rights Guard:
- Export Controlled:
- Controlled Technical Data Package (TDP):
- Restricted Technical Data Package (TDP):
- Contains Classified Material
- Weapons System Indicator Code (WSIC):
- F
Packaging Requirements
- Packaging Determination Table:
- Packaging Review Code:
- N
- Special Packaging Instruction Number (SPIN):
- Special Packaging Instruction Number Revision:
- Special Packaging Instruction Number Date:
- Pallet Reference Number Required: