Premium Information is available for this item - Upgrade for $1 a day
4130-01-533-1523
Air Cooler Unit
4130015331523 015331523 H830RR-A FCU H8-3.0KW RH LVR 83D4080
A unit comprising a fin and tube heat transfer element, filters and may or may not have a motor driven fan, inclosed in a casing for the purpose of cooling and removing moisture from the air in a space where the unit is installed. It may include electric heater and/or electrostatic precipitator. Excludes units containing compressor, condenser and means for introducing air from outside sources. View more Air Cooler Unit
August 2023
5

Marketplace 4130-01-533-1523
Request a Quotation from participating marketplace vendors
Related Documents 4130-01-533-1523 5+ Documents (More...)
United States (US) 4. 4130-01-533-1523 Marketplace Restrictions Approved Sources Datasheet Management
BUY NE FedMall Updated Every Day 4130-01-533-1523 RQST NE Updated Every Day 4130-01-533-1523 RQST
Air Cooler Unit 4130015331523 015331523 Account Upgrade 4130-01-533-1523Air Cooler Unit4130015331523
015331523 H830RR-A FCU H8-3.0KW RH LVR 83D4080 4130-01-533-0208 Air Cooler Unit 4130015330208015330208
Air Cooler Unit 4130015331523 015331523 Account Upgrade 4130-01-533-1523Air Cooler Unit4130015331523
015331523 H830RR-A FCU H8-3.0KW RH LVR 83D4080 Air Cooler Unit 4130013728677013728677 4130-01-372-8677Air
5966Nonimmersion Type Electrical Heating Element4520014845966 014845966571X-67802-1060 7571X-67802-10607 83D4080
7571X-67802-1060783D4080 FIND 5C An electrical https//www.nsnlookup.com /fsg-41/fsc-4130/us 4130-01-533-1523
https//www.nsnlookup.com /fsg-41/fsc-4130/us 4130-01-372-8677 Air Cooler Unit H8-3.0KW RH LVR 83D4080
Air Cooler Unit 4130015331523 015331523 01-372-4725Nonimmersion Type Electrical Heating https//
Restrictions 4130-01-533-1523
4130-01-533-1523 is a Air Cooler Unit that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. The precious metals content of this item is unknown.
End Users 4130-01-533-1523
- US Navy (N9BZ)
- Effective Date:
- 1 Sep 2006
- Former MOE Rule:
- N9ZD
- Supplementary Collaborators:
- HX
Approved Sources 4130-01-533-1523
- Part Number
- Manufacturer
- Status
- H830RR-A
- Manufacturer
- 38450 - Engineered Coil Company (Active)
- Primary Buy
- Primary Buy
- FCU H8-3.0KW RH LVR
- 38450 - Engineered Coil Company (Active)
- Secondary Buy
- Secondary Buy
- 83D4080
- 38450 - Engineered Coil Company (Active)
- Informational Drawing
- Informational Drawing
Datasheet 4130-01-533-1523
- Characteristic
- Specifications
- FIIG
- Specifications
- T240-C
- Case Material [ADTV]
- Steel, Galvanized
- Case With Built-In Condensate Drain Pan [AWLZ]
- Included
- Coil Tube Quantity [AWLQ]
- 1
- Connection Type [AWLS]
- Flange Union
- Cooling Medium [ACZV]
- Chilled Water
- Current Type [ACDC]
- Ac Fan Motor
- Current Type [ACDC]
- Ac Heater
- Fan Drive Type [AWMB]
- Direct
- Fan Type [AWMA]
- Centrifugal
- Frequency In Hertz [FREQ]
- 60.0 Fan Motor
- Frequency In Hertz [FREQ]
- 60.0 Heater
- Heater Wattage Rating In Kilowatts [CWMQ]
- 3.0
- Nominal Capacity In Btu Per Hour [CWMP]
- 72920.0 Heating And 72920.0 Cooling
- Operating Speed At Rated Capacity In Rpm [AEQC]
- 1800.0
- Overall Width [ABMK]
- 62.000 Inches Nominal
- Return Connection Size [AWLW]
- .625 In. Od
- Overall Depth [ABFY]
- 17.000 Inches Nominal
- Overall Height [ABKW]
- 52.000 Inches Nominal
- Part Name Assigned By Controlling Agency [CXCY]
- Fan Coil Unit
- Phase [FAAZ]
- Three Fan Motor
- Phase [FAAZ]
- Three Heater
- Special Features [FEAT]
- High Impact Shock Resistant,Has Lvr (Low Voltage Release) Capacity,With Non-Sealed Insulation System Motor
- Tube Circuit Quantity [AWLR]
- 32
- Tube Material [AWGJ]
- Copper
- Voltage In Volts [ELEC]
- 440.0 Fan Motor
- Voltage In Volts [ELEC]
- 440.0 Heater
- Supply Connection Size [AWLT]
- .625 In. Od
Weapon Systems (WSDC) 4130-01-533-1523
DLA Procurement Analysis 4130-01-533-1523
- Last Stock Position:
- 1 In Stock
- DLA Administrative Lead Time:
- Subscribe
- DLA Production Lead Time:
- Subscribe
Management Data 4130-01-533-1523
- Effective Date
- Organization
- Unit of Issue
- Unit Price
- Qty Unit Pack
- Unit of Issue
- Dec 2022
- Department of the Navy (DN)
- EA
- Subscribe
- 1
- EA
- Oct 2022
- Defense Logistics Agency (DS)
- EA
- Subscribe
- 1
- EA
- Oct 2021
- Department of the Navy (DN)
- EA
- Subscribe
- 1
- EA
- Jun 2021
- Department of the Navy (DN)
- EA
- Subscribe
- 1
- EA
- Oct 2019
- Department of the Navy (DN)
- EA
- Subscribe
- 1
- EA
Navy
- Cognizance:
- 9B
- Navy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Similar Supply Items to 4130-01-533-1523


















Freight Information 4130-01-533-1523
4130-01-533-1523 has freight characteristics managed by the Southwestern Power Administration.It has a National Motor Freight Classification (NMFC) of 053025. A Sub NMFC of Z. It has a NMFC Description of COOLERS,ICEBOXES,REFRIGERATORS. 4130-01-533-1523 is rated as a variable freight class when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 30658 which rates the freight between FCL and LCL. 4130-01-533-1523 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 658 for ocean manifesting and military sealift. 4130-01-533-1523 is not classified as a special type of cargo when transported by water. 4130-01-533-1523 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.
Packaging Data 4130-01-533-1523
- Responsible Activity
- Packaging Data Source
- Primary Inventory Control Activity (PICA)
- --
Item Pack Level (Unpackaged)
- Item Size
- Item Weight
- Characteristics
- Weight/Dimensions Category
- Fragility
- Item Preservation
- Item Weight
- --
- --
- Bare Metal Item
- Over 10lb
- Less than 85G
- Special Requirement
- --
Unit Pack Level (Packaged)
- Quantity per Pack
- Unit Size
- Unit Weight
- Unit Cube
- Preservation Method
- Cleaning/Drying
- Unit Size
- 1
- --
- --
- --
- Physical Protection
- Any Suitable Process
- --
- Preservation Material
- Wrapping Material
- Cushioning/Dunnage
- Cushioning Thickness
- Container
- Special Marking
- Wrapping Material
- --
- --
- --
- --
- PPP-B-566, PPP-B-676, or ASTM-D5118, Folding, Setup or Fiberboard Box
- No special marking
- --
Intermediate Pack Level
- Quantity of Unit Packs
- Container
- --
Contracting Technical Data File (CTDF) 4130-01-533-1523 October 2021
Criticality and Quality
- Critical Item Code:
- Flight Safety:
- Life Support:
- Certified Samples:
- Serialization:
- First Article Test (FAT):
- Certificate of Quality Compliance:
- Production Lot Testing:
- Special Testing:
- Qualified Products List (QPL):
Commercial Properties
- Government Furnished Material:
- Government Furnished Tooling:
- Government Furnished Property:
- Price Evaluation Code:
- Diminshing Manufacturing Sources:
- Warranty:
- Commerical Off The Shelf (COTS):
- End Item Application:
- Auctioning Candidate:
- Source of Procurement:
- Contract Option:
Restrictions
- Boeing Rights Guard:
- Export Controlled:
- Controlled Technical Data Package (TDP):
- Restricted Technical Data Package (TDP):
- Contains Classified Material
- Weapons System Indicator Code (WSIC):
- T
Packaging Requirements
- Packaging Determination Table:
- Packaging Review Code:
- Special Packaging Instruction Number (SPIN):
- Special Packaging Instruction Number Revision:
- Special Packaging Instruction Number Date:
- Pallet Reference Number Required: