Premium Information is available for this item - Upgrade for $1 a day
2920-00-508-1158
Engine Generator Regulator
2920005081158 005081158 1118677
A regulator designed to automatically maintain the current and/or voltage output of an engine generator within specified limits, regardless of variation of load or input voltages. May include cutout relay. Does not include items in which regulation is accomplished by transformer action. See also REGULATOR, CURRENT and REGULATOR, VOLTAGE. View more Engine Generator Regulator
January 2023
6

Marketplace 2920-00-508-1158
Request a Quotation from participating marketplace vendors
Related Documents 2920-00-508-1158 1+ Documents (More...)
Day 2920-00-508-1158 RQST NE Related Documents 2920-00-508-1158 1+ Documents ( More... ) https//www.nsnlookup.com
/fsg-29/fsc-2920/us 2920-00-508-1158 Engine Generator Regulator 2920005081158 1118677 A regulator designed
Restrictions 2920-00-508-1158
2920-00-508-1158 is a Engine Generator Regulator that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. The precious metals content of this item is unknown.
Import and Export 2920-00-508-1158
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 2920-00-508-1158
- Greece (ZU01)
- Effective Date:
- 1 Apr 1991
- Turkey (ZW01)
- Effective Date:
- 1 Nov 2005
Approved Sources 2920-00-508-1158
- Part Number
- Manufacturer
- Status
- 1118677
- Manufacturer
- 16764 - General Motors Corp Delco Remy Div (Replaced)
- Original Design
- Original Design
- 1118677
- 24617 - General Motors Corp (Active)
- Canceled/Obsolete
- Canceled/Obsolete
- 1118677
- 61928 - General Motors Corp Ac-Delco Div (Obsolete)
- Canceled/Obsolete
- Canceled/Obsolete
- 1118677
- 1LW55 - Borgwarner Pds (Anderson), L.L.C. (Active)
- Advisory Reference
- Advisory Reference
Datasheet 2920-00-508-1158
- Characteristic
- Specifications
- FIIG
- Specifications
- A18400
- Center To Center Distance Between Slotted Holes Along Length [APAT]
- 6.000 Inches Nominal
- Center To Center Distance Between Slotted Holes And Plain Holes Along Width [APAW]
- 5.380 Inches Maximum Err-100 Err-100
- Center To Center Distance Between Slotted Holes And Plain Holes Along Width [APAW]
- 5.370 Inches Minimum Err-100 Err-100
- Conduit Connection Quantity [ANZF]
- 1
- Current Regulator Unit Quantity [ANYK]
- 1
- Current Regulator Unit Type [ANYJ]
- Wire Wound Coil
- Distance Between Holes Along Length [ADNY]
- 6.000 Inches Nominal
- Environmental Protection [ADZC]
- Fungus Resistant Err-100 Err-100
- Environmental Protection [ADZC]
- Watertight Err-100 Err-100
- Mounting Hole Diameter [ABTB]
- 0.325 Inches Minimum Err-100 Err-100
- Mounting Hole Diameter [ABTB]
- 0.330 Inches Maximum Err-100 Err-100
- Mounting Slot Length [ABVG]
- 0.448 Inches Minimum Err-100 Err-100
- Mounting Slot Length [ABVG]
- 0.458 Inches Maximum Err-100 Err-100
- Mounting Slot Width [ABTD]
- 0.325 Inches Minimum Err-100 Err-100
- Mounting Slot Width [ABTD]
- 0.330 Inches Maximum Err-100 Err-100
- Mounting Style [ADER]
- Two Plain Holes Two Slotted Holes
- Output Current Rating In Amps [ANYP]
- 20.0 Nominal
- Radio Interference Shielding [ALBH]
- Not Provided
- Shock Mount [AGBC]
- Not Provided
- Voltage Regulator Unit Quantity [ANYH]
- 1
- Voltage Regulator Unit Type [ANYE]
- Wire Wound Coil
- System Ground Polarity [ANYD]
- Negative
- System Voltage Rating [ANYC]
- 24.0
- Terminal Encasement [ANZE]
- Encased
- Terminal Quantity [AARA]
- 3
- Terminal Type [AARB]
- Threaded Stud
Similar Supply Items to 2920-00-508-1158


















Freight Information 2920-00-508-1158
2920-00-508-1158 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 062920. A Sub NMFC of Z. It has a NMFC Description of REGULATORS INDUCTION/VOLTAGE. 2920-00-508-1158 is rated as a variable freight class when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 35120 which rates the freight between FCL and LCL. 2920-00-508-1158 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 658 for ocean manifesting and military sealift. 2920-00-508-1158 is not classified as a special type of cargo when transported by water. 2920-00-508-1158 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.
Packaging Data 2920-00-508-1158
- Responsible Activity
- Packaging Data Source
- Primary Inventory Control Activity (PICA)
- --
Item Pack Level (Unpackaged)
- Item Size
- Item Weight
- Characteristics
- Weight/Dimensions Category
- Fragility
- Item Preservation
- Item Weight
- --
- --
- Bare Metal Item
- Over 10lb
- Less than 85G
- Special Requirement
- --
Unit Pack Level (Packaged)
- Quantity per Pack
- Unit Size
- Unit Weight
- Unit Cube
- Preservation Method
- Cleaning/Drying
- Unit Size
- --
- --
- --
- --
- --
- Any Suitable Process
- --
- Preservation Material
- Wrapping Material
- Cushioning/Dunnage
- Cushioning Thickness
- Container
- Special Marking
- Wrapping Material
- No Requirement
- --
- --
- --
- PPP-B-566, PPP-B-676, or ASTM-D5118, Folding, Setup or Fiberboard Box
- No special marking
- --
Intermediate Pack Level
- Quantity of Unit Packs
- Container
- ASTM-D5118, Type CF, Class Weather-Resistant, Corrugated Fiberboard Box