Premium Information is available for this item - Upgrade for $1 a day

1660-01-528-5726

Aircraft Ejection Seat Oxygen System

1660015285726 015285726 8020130-9

An ejection seat / ejection seat harness mounted system which primarily provides the pilot with oxygen from main oxygen supply in normal flying conditions. In case of emergency such as ejection, damaged hoses, and the like, it provides the same function after disconnection or deprivation from main oxygen supply. It generally consists of an oxygen regulator, a connection box, an anti-G valve, hoses, fittings, emergency oxygen suit, and the like. Excludes OXYGEN SYSTEM,AIRCRAFT SURVIVAL KIT. View more Aircraft Ejection Seat Oxygen System

1660-01-528-5726 OXYGEN SYSTEM,EJECTION SEAT,AIRCRAFT 1660015285726 015285726

Managed by United States
NSN Created on 17 Mar 2005
Data Last Changed
January 2023
NATO Update Count
1
NATO Data Quality
1660-01-528-5726 OXYGEN SYSTEM,EJECTION SEAT,AIRCRAFT 1660015285726 015285726 1/1
NSN 1660-01-528-5726 (Generic Image) 1/1

1660-01-528-5726 Stock and Availability Marketplace 1660-01-528-5726

Need Help?
Request a Quotation from participating marketplace vendors
eBay Updated Every Day
1660-01-528-5726 RQST NE eBay
eBay Updated Every Day
1660-01-528-5726 RQST eBay
Amazon Updated Every Day
1660-01-528-5726 RQST NE Amazon

1660-01-528-5726 Related Documents Related Documents 1660-01-528-5726 5+ Documents (More...)

8020130-9 An ejection seat / ejection seat harness mounted system which primarily provides the pilot
United States (US) 4. 1660-01-528-5726 Marketplace Restrictions Approved Sources Datasheet Management
RQST NE Updated Every Day 1660-01-528-5726 RQST Updated Every Day 1660-01-528-5726 RQST NE Related Documents
-99-434-5266 1660-99-581-5867 Aircraft Ejection Seat Oxygen System 502-3980 1660-14-481-9411 1660-01-528-5726
-99-434-5266 1660-99-581-5867 Aircraft Ejection Seat Oxygen System 502-3980 1660-14-481-9411 1660-01-528-5726
1660-99-434-5266 1660-99-581-5867 Seat Oxygen System 509-3237 1660-01-502-3980 1660-14-481-9411 1660-01-528-5726
Ejection Seat Oxygen System 502-3980 1660-14-481-9411 https//www.nsnlookup.com /fsg-16/fsc-1660/us 1660-01-528-5726
Seat Oxygen System -01-528-5726 Aircraft Ejection Seat Oxygen System 502-3980 1660-14-481-9411 1660-01-528-5726
1660-99-434-5266 -01-522-4255 Aircraft Ejection Seat Oxygen System 502-3980 1660-14-481-9411 1660-01-528-5726
1660-99-434-5266 -01-522-4255 Aircraft Ejection Seat Oxygen System 502-3980 1660-14-481-9411 1660-01-528-5726
1660-99-434-5266 -01-473-2858 Aircraft Ejection Seat Oxygen System 502-3980 1660-14-481-9411 1660-01-528-5726
-99-434-5266 Aircraft Ejection Seat Oxygen System 509-3237 1660-01-502-3980 1660-14-481-9411 1660-01-528-5726
4455Defense Logistics Agency (DS)IZDiscontinued-Use 1660-01-602-4455 502-3980 1660-14-481-9411 1660-01-528-5726
Aircraft Ejection Seat Oxygen System 502-3980 1660-14-481-9411 1660-01-528-5726 1660-99-434-5266
/fsc-1660/us 1660-01-522-4255 Aircraft Ejection Seat Oxygen System 502-3980 1660-14-481-9411 1660-01-528-5726

1660-01-528-5726 Demil Restrictions 1660-01-528-5726

DEMIL: A | DEMILI: 1 | CRITICALITY: X | HMIC: N | PMIC: A | EDC: A | ADPEC: 0

1660-01-528-5726 is a Aircraft Ejection Seat Oxygen System that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. This item does not contain a precious metal.

1660-01-528-5726 HTS and ScheduleB Import and Export 1660-01-528-5726

1660-01-528-5726 End Users End Users 1660-01-528-5726

Czech Republic (WZ01)
Effective Date:
1 Mar 2005

1660-01-528-5726 Manufacturers Approved Sources 1660-01-528-5726

1660-01-528-5726 Technical Data Datasheet 1660-01-528-5726

Characteristic
Specifications
FIIG
A23800
Furnished Items [AFJH]
Portable Oxygen Console; Personal Oxygen System; Parachutist Oxygen Regulator
Special Features [FEAT]
Portable Oxygen Console Has 6 Outlets With Positive Lock Female Hose Connections, On-Off Valve, Tie-Down Anchors, Pressure Reducer Gage; Console Oxygen Hose Is 98 In, Connects With Positive Lock Male Connector; Personal Oxygen System Is Twin 22 Cubic In Or Twin 50 Cubic In Oxygen Cylinders, Pressure Reducer With Gage, Pressure Relief, Fill Valve, On/Off Switch, 19 Or 36 In Hose; Parachutist Oxygen Regulator Isa 100% Oxygen Regulator, Combined Relief/Anti-Suffocation Valve, Operating Altitude Ceiling Is 40000.0 Ft With A Flow Up To 180 Slpm; Inhalation Hose Comes From Left Or Right Side Of Mask, Hose Is Noncrushable, Exhalation Valve Prevents Freezing During Cold Operations

1660-01-528-5726 Related Items NATO Stock Numbers Related to 1660-01-528-5726

1660-01-528-5726 Freight Data Freight Information 1660-01-528-5726

1660-01-528-5726 has freight characteristics managed by the Democratic Republic of Congo.. 1660-01-528-5726 has a variance between NMFC and UFC when transported by rail and the description should be consulted.