TM-9-2350-260-20-1-2 M60 Hull Organizational Maintenance Volume 2 Download

Page 68 of 772

TM 9-2350-260-20-1-2 2A ENGINE AND 2D ENGINE POWERPLANT TESTS (GROUND HOP) (Sheet 7 of 16) GOVERNED NO-LOAD TEST: 1. Start and operate engine until engine oil and transmission oil normal operating temperatures are reached (TM 9-2350-260-10). WARNING Take all necessary safety precautions to eliminate possible injury to personnel or damage to equipment. Stand clear of both transmission output flanges whenever engine is running. Hearing protection is required. NOTE An indicator on the linkage shaft and four dots on the body transmission valve casting indicate shift position. 2. Be sure transmission is in neutral position by checking shifting position indicator. If not in neutral position, grasp shift lever and pull or push lever to set indicator to desired position. Go on to Sheet 8 TA147958 5-58