TM-9-2350-260-20-1-2 M60 Hull Organizational Maintenance Volume 2 Download
Page 610 of 772
TM 9-2350-260-20-1-2 MANIFOLD HEATER FUEL RETURN SOLENOID VALVE REPLACEMENT (Sheet 5 of 5) 5. Place solenoid valve (D) with fittings on bracket. Position solenoid valve so the electrical connector is facing rearward. 6. Using 5/16 inch wrench, install two screws and washers (F) to secure solenoid valve (D) to bracket. 7. Connect hose assembly (G) to elbow (H). Using 9/16 inch wrench, tighten hose assembly (G) to elbow (H). 8. Connect two fuel lines (J) to tee (K). Using 9/16 inch wrench, tighten fuel lines (J) to tee (K). 9. Using spanner wrench, install electrical connector (L) to valve. 10. Operate primer pump (TM 9-2350-260-10). Check for leaks. If leaks are found, correct as necessary. 11. Install engine shroud (page 9-3). End of Task TA148416 7-341