TM 9-2350-260-20-1-2 PRIMER PUMP REPLACEMENT (Sheet 4 of 4) 5. Using 9/16 inch wrench, install inlet tube (E) and heater tube (F) on tee (C). 6. Using 9/16 inch wrench, install outlet tube (G) on adapter (D). 7. Apply silicone compound (Item 32, Appendix D) to two electrical connectors (H). 8. Connect two electrical connectors (H) located on handle support bracket (J) by pushing together. 9. Raise handle to up position. Using 7/16 inch wrench, install wire bracket (K) with bolt (L). End of Task TA148398 7-323