TM 9-2350-260-20-1-2 PRIMER PUMP REPLACEMENT (Sheet 2 of 4) REMOVAL: 1. Disconnect two electrical connectors (A) located on handle support bracket (B) by pulling apart. 2. Raise handle to the up position. Using 7/16 inch wrench, remove bolt and wire bracket (C). 3. Using 9/16 inch wrench, remove heater tube nut (D) and outlet tube nut (E) from primer pump (F). 4. Pull back two tubes (G) from primer pump (F). 5. Using 9/16 inch wrench, remove inlet tube nut (H) from tee (J). 6. Using 1/2 inch wrench, remove tee (J) and adapter (K) from primer pump (F). Go on to Sheet 3 TA148396 7-321