TM-9-2350-260-20-1-2 M60 Hull Organizational Maintenance Volume 2 Download
Page 522 of 772
TM 9-2350-260-20-1-2 FUEL-WATER SEPARATOR OPERATIONAL TESTS (2D ENGINE) (Sheet 9 of 11) WARNING Do not let upper (E) and lower (F) sensor probes come into direct contact with each other. Do not let upper (E) or lower (F) sensor probes come into contact with metal container (G). Hold insulated cables (H) attached to upper (E) and lower (F) sensor probes. Do not touch either probe. NOTE Steps 8 thru 11 must be performed within 15 seconds. 8. Hold tip of lower () sensor probe in water in metal container (G). 9. Hold tip of upper (E) sensor probe in water in metal container (G) and check if fluid starts draining from solenoid drain valve drain tube (J). 10. Remove tip of upper (E) sensor probe from water in metal container (G) and check if fluid keeps draining from solenoid drain valve drain tube (J). Go on to Sheet 10 TA148328 7-253