TM-9-2350-260-20-1-2 M60 Hull Organizational Maintenance Volume 2 Download
Page 520 of 772
TM 9-2350-260-20-1-2 FUEL-WATER SEPARATOR OPERATIONAL TESTS (2D ENGINE) (Sheet 7 of 11) WARNING Do not let upper (E) and lower (F) sensor probes come into direct contact with each other. Do not let upper (E) or lower (F) sensor probes come into contact with metal container (G). Hold insulated cables (J) attached to upper (E) and lower (F) sensor probes. Do not touch either probe. 8. Hold tips of both upper (E) and lower (F) sensor probes in water in metal container (G) until fluid stops draining from solenoid drain valve drain tube (H). 9. If fluid does not stop draining from solenoid drain valve drain tube (H) within 15-20 seconds from starting, refer to troubleshooting procedures (page 4-256). 10. If fluid does begin draining go to step 11 and then to sequential drain test on next page. 11. Remove upper (E) and lower (F) sensor probes from metal container (G). Go on to Sheet 8 TA148326 7-251