TM-9-2350-260-20-1-2 M60 Hull Organizational Maintenance Volume 2 Download

Page 45 of 772

TM 9-2350-260-20-1-2 POWERPLANT REPLACEMENT (2D ENGINE) (Sheet 10 of 26) NOTE When removing screw (AJ) hold onto quick-disconnect ring (AK). Or it will snap open and fall down into engine compartment. 26. Using 3/4 inch socket, remove screw (AJ) securing quick-disconnect ring (AK). 27. Remove both rings (AK). 28. Using hammer and pinch bar, tap final drive adapter (AL) toward final drive (both ides) far enough to free adapter from universal joint. NOTE Continue tapping final drive adapter (it will move 1-1/2 inches) until gears release. 29. Hang two fabricated final drive guide shields (Fig. 1, Appendix F) (one on each side) at final drive universal joints (AM) to prevent hangups when powerplant Is removed. Go on to Sheet 11 TA147936 5-35