TM-9-2350-260-20-1-2 M60 Hull Organizational Maintenance Volume 2 Download

Page 426 of 772

TM 9-2350-260-20-1-2 DRAINING FUEL TANK AND REMOVING CONDENSATE (Sheet 5 of 7) REMOVING CONDENSATE: CAUTION Use care not to spill fuel over tank. Wipe away any spilled fuel immediately with rags. 1. Operate pump handle (A) to transfer fuel from fuel tank to 55 gallon drum (B). 2. Continue operating pump handle (A) until all fuel has been removed from fuel tank. REMOVAL OF HAND PUMP: 1. Using one hand to push quick-disconnect (A) down, remove adapter (B) from quick-disconnect (A). 2. Install dust cover (C) on quick-disconnect (A) by pushing dust cover (C) down until it snaps into place. 3. Remove adapter (B) from suction hose (D). Go on to Sheet 6 TA148232 7-157